Custom Query (1359 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (22 - 24 of 1359)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Ticket Resolution Summary Owner Reporter
#1475 fixed Drive submission - SAMSUNG MZ7LF192HCGS-000L1 Christian Franke xpdite
#1659 fixed WD-Blue-SA510 not in smartctl database Gabriele Pohl xokrateok
Description

Hi there,

WD-Blue-SA510 is not in smartctl database

I also get the warning

SMART ATA Error Log Structure error: invalid SMART checksum

but that's a minor issue, I guess.

Thank you in advance and keep up the good work!

smartctl -x:

smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.0-18-amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WD Blue SA510 2.5 1000GB
Serial Number:    22243V460411
LU WWN Device Id: 5 001b44 4a543d67b
Firmware Version: 52008100
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
TRIM Command:     Available, deterministic
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-4, ACS-2 T13/2015-D revision 3
SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Mon Oct 17 21:51:28 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x71) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (  10) minutes.
Conveyance self-test routine
recommended polling time: 	 (   1) minutes.

SMART Attributes Data Structure revision number: 0
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  5 Reallocated_Sector_Ct   -O--CK   100   100   010    -    0
  9 Power_On_Hours          -O--CK   100   100   000    -    14
 12 Power_Cycle_Count       -O--CK   100   100   000    -    18
165 Unknown_Attribute       -O--CK   100   100   000    -    524294
166 Unknown_Attribute       -O--CK   100   100   000    -    0
167 Unknown_Attribute       -O--CK   100   100   000    -    36
168 Unknown_Attribute       -O--CK   100   100   000    -    1
169 Unknown_Attribute       -O--CK   100   100   000    -    372
170 Unknown_Attribute       -O--CK   100   100   000    -    0
171 Unknown_Attribute       -O--CK   100   100   000    -    0
172 Unknown_Attribute       -O--CK   100   100   000    -    0
173 Unknown_Attribute       -O--CK   100   100   005    -    0
174 Unknown_Attribute       -O--CK   100   100   000    -    0
184 End-to-End_Error        -O--CK   100   100   097    -    0
187 Reported_Uncorrect      -O--CK   100   100   000    -    0
188 Command_Timeout         -O--CK   100   100   000    -    0
194 Temperature_Celsius     -O---K   100   100   014    -    28 (Min/Max 18/31)
199 UDMA_CRC_Error_Count    -O--CK   100   100   000    -    0
230 Unknown_SSD_Attribute   -O--CK   100   100   000    -    4294967297
232 Available_Reservd_Space PO--CK   100   100   004    -    85
233 Media_Wearout_Indicator -O--CK   100   100   000    -    102
234 Unknown_Attribute       -O--CK   100   100   000    -    229
241 Total_LBAs_Written      ----CK   253   253   000    -    205
242 Total_LBAs_Read         ----CK   253   253   000    -    16
244 Unknown_Attribute       -O--CK   100   100   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      1  Comprehensive SMART error log
0x03       GPL     R/O     16  Ext. Comprehensive SMART error log
0x04       GPL,SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa1  GPL,SL  VS       1  Device vendor specific log
0xa2       GPL,SL  VS       2  Device vendor specific log
0xa3-0xa7  GPL,SL  VS       1  Device vendor specific log
0xde       GPL,SL  VS       1  Device vendor specific log

Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 1 (16 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%        14         -
# 2  Short offline       Completed without error       00%        12         -
# 3  Extended offline    Completed without error       00%        12         -
# 4  Short offline       Completed without error       00%        11         -
# 5  Extended offline    Completed without error       00%        10         -
# 6  Short offline       Completed without error       00%         8         -
# 7  Short offline       Completed without error       00%         8         -
# 8  Extended offline    Completed without error       00%         8         -
# 9  Short offline       Completed without error       00%         7         -
#10  Short offline       Completed without error       00%         7         -
#11  Short offline       Completed without error       00%         7         -
#12  Extended offline    Completed without error       00%         6         -
#13  Short offline       Completed without error       00%         3         -
#14  Short offline       Completed without error       00%         3         -
#15  Extended offline    Completed without error       10%         3         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Commands not supported

Device Statistics (GP Log 0x04)
Page  Offset Size        Value Flags Description
0x01  =====  =               =  ===  == General Statistics (empty) ==
0x05  =====  =               =  ===  == Temperature Statistics (empty) ==
0x07  =====  =               =  ===  == Solid State Device Statistics (empty) ==
                                |||_ C monitored condition met
                                ||__ D supports DSN
                                |___ N normalized value

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0009  2            0  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            6  Device-to-host register FISes sent due to a COMRESET
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC
#233 wontfix Impossible to access to the physical disks behind a 3Ware 9650 RAID card Christian Franke xmilha
Description

I have an 3Ware 9650 RAID card with 4 physical disks (Samsung HD203WI with tler modifiable) and 4 logical partitions but I can't access to the physical disks, when I type (for example) smartctl -i /dev/sdc,1 or smartctl -i /dev/sdc,2 I get informations on the partitions and not informations on the disks. So I can't change the TLER parameter of my disks.

The OS is Windows 2003, the smartmontools version is 5.43, the 3Ware driver version is 3.00.05.056 and the firmware is 4.10.00.026.

smartctl -i /dev/sdb,1

smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-2003-sp2] (sf-5.43-1) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

Vendor: LSI Product: 9650SE-16ML Revision: 4.10 User Capacity: 2á999á967á547á392 bytes [2,99 TB] Logical block size: 512 bytes Logical Unit id: 0x600050e0c12df40038490000af5b0000 Serial number: WZ502711C12DF4003849 Device type: disk scsiModePageOffset: response length too short, resp_len=4 offset=4 bd_len=0 Local Time is: Sun Aug 12 13:40:09 2012 PM Device supports SMART and is Disabled Temperature Warning Disabled or Not Supported

smartctl -i /dev/sdb,2

smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-2003-sp2] (sf-5.43-1) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

Vendor: LSI Product: 9650SE-16ML Revision: 4.10 User Capacity: 2á999á967á547á392 bytes [2,99 TB] Logical block size: 512 bytes Logical Unit id: 0x600050e0c12df40038490000af5b0000 Serial number: WZ502711C12DF4003849 Device type: disk scsiModePageOffset: response length too short, resp_len=4 offset=4 bd_len=0 Local Time is: Sun Aug 12 13:40:14 2012 PM Device supports SMART and is Disabled Temperature Warning Disabled or Not Supported

smartctl -i /dev/sdc,1

smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-2003-sp2] (sf-5.43-1) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

Vendor: LSI Product: 9650SE-16ML Revision: 4.10 User Capacity: 1á999á988á850á688 bytes [1,99 TB] Logical block size: 512 bytes Logical Unit id: 0x600050e0c0fa1800524d000053430000 Serial number: WZ707793C0FA1800524D Device type: disk scsiModePageOffset: response length too short, resp_len=4 offset=4 bd_len=0 Local Time is: Sun Aug 12 13:15:40 2012 PM Device supports SMART and is Disabled Temperature Warning Disabled or Not Supported

smartctl -i /dev/sdc,2

smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-2003-sp2] (sf-5.43-1) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

Vendor: LSI Product: 9650SE-16ML Revision: 4.10 User Capacity: 1á999á988á850á688 bytes [1,99 TB] Logical block size: 512 bytes Logical Unit id: 0x600050e0c0fa1800524d000053430000 Serial number: WZ707793C0FA1800524D Device type: disk scsiModePageOffset: response length too short, resp_len=4 offset=4 bd_len=0 Local Time is: Sun Aug 12 13:15:43 2012 PM Device supports SMART and is Disabled Temperature Warning Disabled or Not Supported

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.