Custom Query (1376 matches)
Results (166 - 168 of 1376)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#726 | fixed | Add persistent option ",p" to wcreorder,on|off | ||
Description |
Similar to wcache-sct, we can make wcreorder setting persistent through SCT Feature Control. |
|||
#1351 | fixed | InnoDisk Corp. - EDC 1SE2 H 64GB | ||
Description |
https://www.innodisk.com/en/products/flash-storage/embedded-disk-card_edc/edc_1se2_horizontal#tab1 smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: InnoDisk Corp. - EDC 1SE2 H 64GB Firmware Version: 131216 User Capacity: 64.030.244.864 bytes [64,0 GB] Sector Size: 512 bytes logical/physical Device is: Not in smartctl database [for details use: -P showall] ATA Version is: [No Information Found] Local Time is: Fri Jul 17 15:02:47 2020 CEST SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 85-87 don't show if SMART is enabled. Checking to be sure by trying SMART RETURN STATUS command. SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Unavailable Write cache is: Disabled DSN feature is: Unavailable ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Unavailable === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Total time to complete Offline data collection: ( 1) seconds. Offline data collection capabilities: (0x00) Offline data collection not supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x00) Error logging NOT supported. No General Purpose Logging support. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate ------ 100 100 050 - 0 5 Reallocated_Sector_Ct -O---- 100 100 050 - 0 12 Power_Cycle_Count ------ 100 100 050 - 63 160 Unknown_Attribute ------ 100 100 050 - 0 161 Unknown_Attribute ------ 100 100 050 - 591 162 Unknown_Attribute ------ 100 100 050 - 238 163 Unknown_Attribute ------ 100 100 050 - 37 164 Unknown_Attribute ------ 100 100 050 - 7203731 165 Unknown_Attribute ------ 100 100 050 - 917 166 Unknown_Attribute ------ 100 100 050 - 849 167 Unknown_Attribute ------ 100 100 050 - 884 192 Power-Off_Retract_Count ------ 100 100 050 - 0 194 Temperature_Celsius ------ 100 100 000 - 46 (Min/Max 39/66) 195 Hardware_ECC_Recovered ------ 100 100 050 - 0 196 Reallocated_Event_Count ------ 100 100 050 - 0 198 Offline_Uncorrectable ------ 000 000 000 - 0 199 UDMA_CRC_Error_Count ------ 100 100 050 - 0 241 Total_LBAs_Written -O--CK 100 100 050 - 123704 242 Total_LBAs_Read -O--CK 100 100 050 - 282928 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning Read SMART Log Directory failed: scsi error badly formed scsi parameters ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters Read GP Log Directory failed SMART Extended Comprehensive Error Log (GP Log 0x03) not supported Read SMART Error Log failed: scsi error badly formed scsi parameters SMART Extended Self-test Log (GP Log 0x07) not supported Read SMART Self-test Log failed: scsi error badly formed scsi parameters Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported Pending Defects log (GP Log 0x0c) not supported SATA Phy Event Counters (GP Log 0x11) not supported |
|||
#828 | invalid | Add drive to smartctl database - PM951 NVMe SAMSUNG 256GB | ||
Description |
Hi, Can I request the following drive get added to the smartctl database please. below is output from smartctl.exe -d ata -s on -q noserial -x /dev/sda smartctl 6.5 2016-05-07 r4318 [i686-w64-mingw32-win10(64)] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: PM951 NVMe SAMSUNG 256GB Firmware Version: BXV77D0Q Device is: Not in smartctl database [for details use: -P showall] ATA Version is: [No Information Found] Local Time is: Mon Apr 03 15:44:56 2017 GMTDT SMART support is: Available - device has SMART capability. Enabled status cached by OS, trying SMART RETURN STATUS cmd. SMART support is: Disabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Unavailable Write cache is: Unavailable ATA Security is: Unavailable Wt Cache Reorder: Unavailable === START OF ENABLE/DISABLE COMMANDS SECTION === SMART Enabled. Read SMART Data failed: Function not implemented === START OF READ SMART DATA SECTION === SMART Status not supported: Function not implemented SMART overall-health self-assessment test result: UNKNOWN! SMART Status, Attributes and Thresholds cannot be read. Read SMART Log Directory failed: Input/output error General Purpose Log Directory not supported SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log not supported SMART Extended Self-test Log (GP Log 0x07) not supported SMART Self-test Log not supported Selective Self-tests/Logging not supported SCT Commands not supported Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) not supported |
Note:
See TracQuery
for help on using queries.