Ticket Resolution Summary Owner Reporter
#726 fixed Add persistent option ",p" to wcreorder,on|off Christian Franke Song Liu
Description

Similar to wcache-sct, we can make wcreorder setting persistent through SCT Feature Control.

#1351 fixed InnoDisk Corp. - EDC 1SE2 H 64GB Christian Franke softmove
Description

https://www.innodisk.com/en/products/flash-storage/embedded-disk-card_edc/edc_1se2_horizontal#tab1

smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     InnoDisk Corp. - EDC 1SE2 H 64GB
Firmware Version: 131216
User Capacity:    64.030.244.864 bytes [64,0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   [No Information Found]
Local Time is:    Fri Jul 17 15:02:47 2020 CEST
SMART support is: Ambiguous - ATA IDENTIFY DEVICE words 85-87 don't show if SMART is enabled.
                  Checking to be sure by trying SMART RETURN STATUS command.
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Disabled
Rd look-ahead is: Unavailable
Write cache is:   Disabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x02)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Disabled.
Total time to complete Offline 
data collection: 		(    1) seconds.
Offline data collection
capabilities: 			 (0x00) 	Offline data collection not supported.
SMART capabilities:            (0x0002)	Does not save SMART data before
					entering power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x00)	Error logging NOT supported.
					No General Purpose Logging support.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     ------   100   100   050    -    0
  5 Reallocated_Sector_Ct   -O----   100   100   050    -    0
 12 Power_Cycle_Count       ------   100   100   050    -    63
160 Unknown_Attribute       ------   100   100   050    -    0
161 Unknown_Attribute       ------   100   100   050    -    591
162 Unknown_Attribute       ------   100   100   050    -    238
163 Unknown_Attribute       ------   100   100   050    -    37
164 Unknown_Attribute       ------   100   100   050    -    7203731
165 Unknown_Attribute       ------   100   100   050    -    917
166 Unknown_Attribute       ------   100   100   050    -    849
167 Unknown_Attribute       ------   100   100   050    -    884
192 Power-Off_Retract_Count ------   100   100   050    -    0
194 Temperature_Celsius     ------   100   100   000    -    46 (Min/Max 39/66)
195 Hardware_ECC_Recovered  ------   100   100   050    -    0
196 Reallocated_Event_Count ------   100   100   050    -    0
198 Offline_Uncorrectable   ------   000   000   000    -    0
199 UDMA_CRC_Error_Count    ------   100   100   050    -    0
241 Total_LBAs_Written      -O--CK   100   100   050    -    123704
242 Total_LBAs_Read         -O--CK   100   100   050    -    282928
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: scsi error badly formed scsi parameters

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: scsi error badly formed scsi parameters
Read GP Log Directory failed

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

Read SMART Error Log failed: scsi error badly formed scsi parameters

SMART Extended Self-test Log (GP Log 0x07) not supported

Read SMART Self-test Log failed: scsi error badly formed scsi parameters

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11) not supported


#828 invalid Add drive to smartctl database - PM951 NVMe SAMSUNG 256GB snapback
Description

Hi,

Can I request the following drive get added to the smartctl database please. below is output from smartctl.exe -d ata -s on -q noserial -x /dev/sda

smartctl 6.5 2016-05-07 r4318 [i686-w64-mingw32-win10(64)] (sf-6.5-1)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     PM951 NVMe SAMSUNG 256GB
Firmware Version: BXV77D0Q
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   [No Information Found]
Local Time is:    Mon Apr 03 15:44:56 2017 GMTDT
SMART support is: Available - device has SMART capability.
                  Enabled status cached by OS, trying SMART RETURN STATUS cmd.
SMART support is: Disabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Unavailable
Write cache is:   Unavailable
ATA Security is:  Unavailable
Wt Cache Reorder: Unavailable

=== START OF ENABLE/DISABLE COMMANDS SECTION ===
SMART Enabled.
Read SMART Data failed: Function not implemented


=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Function not implemented
SMART overall-health self-assessment test result: UNKNOWN!
SMART Status, Attributes and Thresholds cannot be read.

Read SMART Log Directory failed: Input/output error

General Purpose Log Directory not supported

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log not supported

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test Log not supported

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11) not supported
Batch Modify
Note: See TracBatchModify for help on using batch modify.