#631 fixed Drive WDC WD4003FZEX needs to be added to smart database opentoe
Description
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.1.13-unRAID] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WDC WD4003FZEX-00Z4SA0
Serial Number:    WD-WCC130966733
LU WWN Device Id: 5 0014ee 25e2bd767
Firmware Version: 01.01A01
User Capacity:    4,000,787,030,016 bytes [4.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    7200 rpm
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Jan 10 16:18:42 2016 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(41640) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 451) minutes.
Conveyance self-test routine
recommended polling time: 	 (   5) minutes.
SCT capabilities: 	       (0x7035)	SCT Status supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR-K   200   200   051    -    0
  3 Spin_Up_Time            POS--K   137   136   021    -    12125
  4 Start_Stop_Count        -O--CK   100   100   000    -    68
  5 Reallocated_Sector_Ct   PO--CK   200   200   140    -    0
  7 Seek_Error_Rate         -OSR-K   200   200   000    -    0
  9 Power_On_Hours          -O--CK   077   077   000    -    17417
 10 Spin_Retry_Count        -O--CK   100   253   000    -    0
 11 Calibration_Retry_Count -O--CK   100   253   000    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    67
192 Power-Off_Retract_Count -O--CK   200   200   000    -    34
193 Load_Cycle_Count        -O--CK   200   200   000    -    33
194 Temperature_Celsius     -O---K   111   098   000    -    41
196 Reallocated_Event_Count -O--CK   200   200   000    -    0
197 Current_Pending_Sector  -O--CK   200   200   000    -    0
198 Offline_Uncorrectable   ----CK   200   200   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
200 Multi_Zone_Error_Rate   ---R--   200   200   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      6  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters
0x24       GPL     R/O      1  Current Device Internal Status Data log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0-0xa7  GPL,SL  VS      16  Device vendor specific log
0xa8-0xb7  GPL,SL  VS       1  Device vendor specific log
0xbd       GPL,SL  VS       1  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xc1       GPL     VS      93  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
No Errors Logged

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     17417         -
# 2  Short offline       Completed without error       00%     17416         -
# 3  Short offline       Completed without error       00%     12833         -
# 4  Short offline       Completed without error       00%     12332         -
# 5  Short offline       Completed without error       00%     11348         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       258 (0x0102)
SCT Support Level:                   1
Device State:                        Active (0)
Current Temperature:                    41 Celsius
Power Cycle Min/Max Temperature:     36/42 Celsius
Lifetime    Min/Max Temperature:     18/54 Celsius
Under/Over Temperature Limit Count:   0/0
SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:           -41/85 Celsius
Temperature History Size (Index):    478 (247)

Index    Estimated Time   Temperature Celsius
 248    2016-01-10 08:21    41  **********************
 ...    ..(238 skipped).    ..  **********************
   9    2016-01-10 12:20    41  **********************
  10    2016-01-10 12:21    42  ***********************
 ...    ..( 15 skipped).    ..  ***********************
  26    2016-01-10 12:37    42  ***********************
  27    2016-01-10 12:38    41  **********************
 ...    ..(219 skipped).    ..  **********************
 247    2016-01-10 16:18    41  **********************

SCT Error Recovery Control command not supported

Device Statistics (GP Log 0x04) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x0001  2            0  Command failed due to ICRC error
0x0002  2            0  R_ERR response for data FIS
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0005  2            0  R_ERR response for non-data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS
0x0008  2            0  Device-to-host non-data FIS retries
0x0009  2            3  Transition from drive PhyRdy to drive PhyNRdy
0x000a  2            4  Device-to-host register FISes sent due to a COMRESET
0x000b  2            0  CRC errors within host-to-device FIS
0x000f  2            0  R_ERR response for host-to-device data FIS, CRC
0x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
0x8000  4        95739  Vendor specific
#780 fixed smartmontools triggers kernel panic on INVARIANTS enabled FreeBSD kernel after r308351 in base op_hardenedbsd
Description

Details from ports patch - https://bugs.freebsd.org/bugzilla/show_bug.cgi?id=215356

smartmontools: fix panic on INVARIANTS enabled kernel after r308351 in base

After r308351 commit the INVARIANTS enabled kernel gets too "eager" when checking the cam ccb flags. But the real problem was not the previous, but the smartmontools does not zeroed out the ccb on stack, and pass this dirty ccb to kernel, which is catched by an ASSERT. So fix this by filling up with 0 this ccb. This commit is similar, what's happen in r307684 in camcontrol. So this is the same followup patch in smartmontools.

https://svnweb.freebsd.org/base?view=revision&revision=307684 https://svnweb.freebsd.org/base?view=revision&revision=308351

Sponsored-by: opBSD

op@opn ~> smartctl --version smartctl 6.5 2016-05-07 r4318 [FreeBSD 11.0-STABLE-HBSD amd64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

smartctl comes with ABSOLUTELY NO WARRANTY. This is free software, and you are welcome to redistribute it under the terms of the GNU General Public License; either version 2, or (at your option) any later version. See http://www.gnu.org for further details.

smartmontools release 6.5 dated 2016-05-07 at 11:17:46 UTC smartmontools SVN rev 4318 dated 2016-05-07 at 11:18:20 smartmontools build host: amd64-portbld-freebsd11.0 smartmontools build with: C++98, GCC 4.2.1 Compatible FreeBSD Clang 3.8.0 (tags/RELEASE_380/final 262564) smartmontools configure arguments: '--disable-dependency-tracking' '--enable-sample' '--with-nvme-devicescan=yes' '--with-initscriptdir=/usr/local/etc/rc.d' '--prefix=/usr/local' '--localstatedir=/var' '--mandir=/usr/local/man' '--disable-silent-rules' '--infodir=/usr/local/info/' '--build=amd64-portbld-freebsd11.0' 'build_alias=amd64-portbld-freebsd11.0' 'CXX=c++' 'CXXFLAGS=-O2 -pipe -pipe -DHARDENEDBSD -fstack-protector -fno-strict-aliasing -DHARDENEDBSD' 'LDFLAGS= -fstack-protector' 'LIBS=' 'CPPFLAGS=' 'CC=cc' 'CFLAGS=-O2 -pipe -pipe -DHARDENEDBSD -fstack-protector -fno-strict-aliasing'

#1248 worksforme smartd fails to start when no disks are present onlyjob
Description

As reported in https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=862908 "smartd" fails to start on the system without disks (e.g. KVM).

It would be better to start the daemon anyway and wait for pluggable disks to appear.

This could help to prevent init system failures on attempted start of "smartd".

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.