Custom Query (1541 matches)
Results (178 - 180 of 1541)
| Ticket | Resolution | Summary | Owner | Reporter |
|---|---|---|---|---|
| #1418 | duplicate | Self-test log life time resets after a certain Power_On_Hours value | ||
| Description |
Just seen an interesting fact on a hard drive with a current Power_On_Hours value of 65966. I launched an extended offline test (using -t long) and the LifeTime (hours) column does not show the real Power_On_Hours value: === START OF INFORMATION SECTION ===
Model Family: Western Digital Green
Device Model: WDC WD20EARX-00PASB0
Serial Number: obfuscated
LU WWN Device Id: 5 0014ee 25c9427f5
Firmware Version: 51.0AB51
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Dec 31 15:56:48 2020 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (38400) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 370) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x3035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 173 167 021 Pre-fail Always - 6341
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 161
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 010 010 000 Old_age Always - 65966
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 161
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 40
193 Load_Cycle_Count 0x0032 153 153 000 Old_age Always - 142788
194 Temperature_Celsius 0x0022 128 110 000 Old_age Always - 22
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 429 -
# 2 Extended offline Completed without error 00% 220 -
# 3 Extended offline Completed without error 00% 63835 -
# 4 Extended offline Completed without error 00% 21182 -
# 5 Extended offline Completed without error 00% 971 -
# 6 Short offline Completed without error 00% 836 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
It seems that the maximum Power_On_Hours value is 65535 (interestingly the same value as the maximum network port range). All values above that are shown as difference LifeTime (hours). Is this a bug? Is this intended? PS I Used smartctl 6.6 for this. |
|||
| #1095 | fixed | Adding Crucial BX500 to db | ||
| Description |
Adding CT120BX500SSD1 to the db Info: https://forums.crucial.com/t5/Crucial-SSDs/MX500-SMART-parameters/td-p/184287 (mx500 is probably the same) and https://listi.jpberlin.de/pipermail/smartmontools-database/2018-April/000176.html |
|||
| #1760 | wontfix | NVMe support for qnx | ||
| Description |
Smartmontools does not support NVMe devices on QNX as per the NVMe wiki page. Is there any enhancement planned to extend existing support to NMVe SSDs? |
|||