#1210 invalid Why was the script unable to run the short test at 7am o'clock? Cesar Murilo
Description

By email, we saw that at 7am o'clock the script was unable to perform any tests for the / dev / sda disk; only for others.

By re-executing the script, the test was performed.

Because the first attempt was not possible? Is there any way to log more deeply to find out the cause?

The result of test at 7am o'clock

SMART Self-test log structure revision number 0 Warning: ATA Specification requires self-test log structure revision number = 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]

The command on script: /usr/sbin/smartctl -i -l selftest -l error -H -t short {devices}

Thanks for replys

#1194 fixed INTEL SSDSC2BF180A4H Christian Franke cfeedback
Description

Unknown OEM Intel Pro 1500 series SSD. I believe the entry in the drivedb for the 53x / Pro 2500 series should also work for this drive.

#980 fixed WD-WDS240G2G0A Christian Franke Alex