Custom Query (1560 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (448 - 450 of 1560)

Ticket Resolution Summary Owner Reporter
#259 fixed Errors when the defect list is too large for the 10byte Read Defect command Doug Gilbert bschwartz89
Description

Some users are experiencing errors with the 10byte version of the Read Defect command for SAS drives. A 12 byte command (operation code B7H) of the Read Defect solves the issue and should be included for smartctl.

#288 invalid Remove failure notice for Attribute 190 somebody bschwartz89
Description

Seagate is requesting that the failure notice on attribute 190 be removed or somehow be tagged with an 'information only' descriptor. The attribute isn't warrantable and isn't an indicator of drive failure. During customer qualifications, our drives are being failed because they see that this attribute has 'failed in the past'.

#1735 worksforme Support for RaidSonic ICY BOX IB-1922MF-C32 USB to NVMe bridge (0x174c:0x2364, ASM2364) bugs.bunny
Description

Hello,

I'm unsure if this is a request for an enhancement or a case like "works as designed". So I apologize in advance if I'm wrong.

I'm using two RaidSonic ICY BOX IB-1922MF-C32 USB to NVMe bridges which have an ASMedia ASM2364 chipset inside. smartmontool is able to print out some information (please see attached outputs). But what moved me to open this ticket are the last lines of the output:

Warning: NVMe Get Log truncated to 0x200 bytes, 0x200 bytes zero filled Error Information (NVMe Log 0x01, 16 of 256 entries)

No matter what tests I run, I don't get any attributes displayed.

Thank you in advance for your support! If you need additional information, outputs, ... please let me know!

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.