Custom Query (1560 matches)
Results (421 - 423 of 1560)
| Ticket | Resolution | Summary | Owner | Reporter |
|---|---|---|---|---|
| #1220 | invalid | smartctl tests are not logged for SanDisk SDSSDA240G drive | ||
| Description |
It looks like smartctl tools cannot properly handle the SanDisk SDSSDA240G drive: whenever I try to run long/short/etc. tests, they are not stored in the SMART log. According to "Self-test execution status" they are indeed run. SanDisk SSD Dashboard utility can run both short and long tests but no matter which test is run, short logs are always recorded: SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 36 - # 2 Short offline Completed without error 00% 35 - # 3 Short offline Completed without error 00% 30 - # 4 Short offline Completed without error 00% 18 - # 5 Short offline Completed without error 00% 5 - Also LifeTime is completely wrong. I've used this drive for at least 1000 hours. SanDisk SSD Dashboard utility does not show logs at all. I'm curious what's going on, whether it's special firmware which is not handled correctly or some issue with my drive. |
|||
| #1317 | fixed | Proper attributes for SanDisk SDSSDA(120|240|480)G | ||
| Description |
No idea how to create a proper patch, so:
Source: Sandisk SSD Utility |
|||
| #1591 | invalid | -H returns an error for an otherwise healthy drive | ||
| Description |
I've got two HDDs with the same issue: smartctl -H /dev/sdb smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-175-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED Please note the following marginal Attributes: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 190 Airflow_Temperature_Cel 0x0022 067 036 045 Old_age Always In_the_past 33 (255 255 33 28 0)
Exit code is 32 despite "SMART overall-health self-assessment test result: PASSED". There's nothing else which is wrong with the drives so the question is, how I can use Here's the complete output: smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-175-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Constellation ES.3 Device Model: ST2000NM0033-9ZM175 Serial Number: [redacted] LU WWN Device Id: 5 000c50 0642fa65b Firmware Version: SN07 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Tue Apr 12 10:33:44 2022 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 248) Self-test routine in progress... 80% of test remaining. Total time to complete Offline data collection: ( 592) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 248) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x50bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 081 063 044 Pre-fail Always - 158005897 3 Spin_Up_Time 0x0003 094 094 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 20 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 22 7 Seek_Error_Rate 0x000f 092 060 030 Pre-fail Always - 1749915271 9 Power_On_Hours 0x0032 059 059 000 Old_age Always - 36027 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 18 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 067 036 045 Old_age Always In_the_past 33 (255 255 33 28 0) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 15 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 1534 194 Temperature_Celsius 0x0022 033 064 000 Old_age Always - 33 (0 26 0 0 0) 195 Hardware_ECC_Recovered 0x001a 024 013 000 Old_age Always - 158005897 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 35972 - |
|||