Custom Query (1566 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (406 - 408 of 1566)

Ticket Resolution Summary Owner Reporter
#1169 duplicate Drive Support - WDC WDS200T2B0A-00SM50 BCCHR Support
Description

I can see the following drive isn't yet in the smartctl database for smartctl 7.0 2018-12-30 r4883. I've included output below.

[root@host:/root/smartmontools-7.0]# smartctl -d megaraid,20 /dev/sda -a
smartctl 7.0 2018-12-30 r4883 [x86_64-linux-3.10.0-693.21.1.el7.x86_64] (local build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     WDC WDS200T2B0A-00SM50
Serial Number:    174901800006
LU WWN Device Id: 5 001b44 8b6844df6
Firmware Version: X61130WD
User Capacity:    2,000,398,934,016 bytes [2.00 TB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ACS-4 T13/BSR INCITS 529 revision 5
SATA Version is:  SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Thu Mar  7 10:17:53 2019 PST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: ATA return descriptor not supported by controller firmware
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x11) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 4
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0032   100   100   ---    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   ---    Old_age   Always       -       8754
 12 Power_Cycle_Count       0x0032   100   100   ---    Old_age   Always       -       35
165 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       77005621
166 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1
167 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       39
168 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       49
169 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       1237
170 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
171 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
172 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       0
173 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       18
174 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       22
184 End-to-End_Error        0x0032   100   100   ---    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   ---    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   ---    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   076   037   ---    Old_age   Always       -       24 (Min/Max 18/37)
199 UDMA_CRC_Error_Count    0x0032   100   100   ---    Old_age   Always       -       0
230 Unknown_SSD_Attribute   0x0032   100   100   ---    Old_age   Always       -       1374411555152
232 Available_Reservd_Space 0x0033   100   100   004    Pre-fail  Always       -       100
233 Media_Wearout_Indicator 0x0032   100   100   ---    Old_age   Always       -       37803
234 Unknown_Attribute       0x0032   100   100   ---    Old_age   Always       -       39878
241 Total_LBAs_Written      0x0030   253   253   ---    Old_age   Offline      -       21669
242 Total_LBAs_Read         0x0030   253   253   ---    Old_age   Offline      -       253116
244 Unknown_Attribute       0x0032   000   100   ---    Old_age   Always       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported
#1288 fixed Could not add entry to USB page Ben Chociej
Description

Attempted to add the following line to https://www.smartmontools.org/wiki/Supported_USB-Devices :

|| Rosewill RX234 SATA III USB 3.0 docking station || JMicron || 0x152d:0x2578 || JMicron Technology Corp. / JMicron USA Technology Corp. USB to SATA bridge || -d sat || Linux 4.19 || bchociej || ||

Upon either submitting or attempting to review changes, the following error was displayed:

Trac detected an internal error: DataError: (1406, "Data too long for column 'request' at row 1")

#621 fixed The incorrect smartctl terminal printout for GLTSD bit Christian Franke bear
Description

T10's SPC-4 specifies the GLTSD bit in section 7.5.10 Control mode page as:

--- A global logging target save disable (GLTSD) bit set to zero specifies that the logical unit implicitly saves, at vendor specific intervals, each log parameter in which the TSD bit (see 7.3) is set to zero. A GLTSD bit set to one specifies that the logical unit shall not implicitly save any log parameters. ---

I have verified the functionality of the smartctl -S [on/off] /dev/sgX command on a SAS drive and believe the output is incorrect.

When you use -S on, you are enabling Autosaving of logs (set GLTSD bit to 0) but the printout says you are setting the GLTSD bit. This printout is incorrect. When you use -S off you are disabling Autosaving of logs (set GLTSD bit to 1) but the printout says you are clearing the GLTSD bit. This printout is incorrect.

(See attached picture)

On the bright side, I have verified that the command does correct set/clear the bit in the Control mode page 0Ah .

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.