Custom Query (1469 matches)
Results (376 - 378 of 1469)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#1215 | invalid | smartctl selects the wrong NVMe device | ||
Description |
In the currently nightly, smartctl, when used on /dev/nvmeX rathern than /dev/nvmeXn1, selects the wrong device when two identical nvme modules are installed. Example: # ls -l nvme-Samsung_SSD_970_EVO_2TB_S464NB0M200088N | cut -c40- nvme-Samsung_SSD_970_EVO_2TB_S464NB0M200088N -> ../../nvme0n1 # ls -l nvme-Samsung_SSD_970_EVO_2TB_S464NB0M200161Y | cut -c40- nvme-Samsung_SSD_970_EVO_2TB_S464NB0M200161Y -> ../../nvme1n1 # ./smartctl -a /dev/nvme0n1 | sed -n '1p;5,7p' smartctl 7.1 2019-07-01 r4934 [x86_64-linux-4.18.0-24-generic] (local build) Model Number: Samsung SSD 970 EVO 2TB Serial Number: S464NB0M200088N Firmware Version: 2B2QEXE7 # ./smartctl -a /dev/nvme1n1 | sed -n '1p;5,7p' smartctl 7.1 2019-07-01 r4934 [x86_64-linux-4.18.0-24-generic] (local build) Model Number: Samsung SSD 970 EVO 2TB Serial Number: S464NB0M200161Y Firmware Version: 2B2QEXE7 # ./smartctl -a /dev/nvme0 | sed -n '1p;5,7p' smartctl 7.1 2019-07-01 r4934 [x86_64-linux-4.18.0-24-generic] (local build) Model Number: Samsung SSD 970 EVO 2TB Serial Number: S464NB0M200161Y Firmware Version: 2B2QEXE7 # ./smartctl -a /dev/nvme1 | sed -n '1p;5,7p' smartctl 7.1 2019-07-01 r4934 [x86_64-linux-4.18.0-24-generic] (local build) Model Number: Samsung SSD 970 EVO 2TB Serial Number: S464NB0M200088N Firmware Version: 2B2QEXE7 |
|||
#668 | fixed | Add new Apple SSD to drive database | ||
Description |
The new Apple SSDs seem to have the same odd values. Someone added 173 as Wear_Leveling_Count which doesn't seem right to me. I added the G model to my local copy. === START OF INFORMATION SECTION === Model Family: Apple SD/SM/TS...E/F SSDs Device Model: APPLE SSD SM0512G Firmware Version: BXW1SA0Q User Capacity: 500,277,790,720 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Mar 14 12:13:03 2016 EDT ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x001a 200 200 000 Old_age Always - 0 5 Reallocated_Sector_Ct 0x0033 100 100 000 Pre-fail Always - 0 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 1060 12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 5651 169 Unknown_Attribute 0x0013 221 221 010 Pre-fail Always - 4222129014656 173 Wear_Leveling_Count 0x0032 198 198 100 Old_age Always - 30069096468 174 Host_Reads_MiB 0x0022 099 099 000 Old_age Always - 7219227 175 Host_Writes_MiB 0x0022 099 099 000 Old_age Always - 8097664 192 Power-Off_Retract_Count 0x0012 099 099 000 Old_age Always - 67 194 Temperature_Celsius 0x0022 077 019 000 Old_age Always - 23 (Min/Max 14/83) 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always - 0 |
|||
#890 | fixed | new drive PNY cs1311 | ||
Description |
Not in drive database, temperate is wrong as well. https://bugs.launchpad.net/ubuntu/+source/libatasmart/+bug/1581594 |
Note:
See TracQuery
for help on using queries.