Custom Query (1405 matches)
Results (28 - 30 of 1405)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#1271 | invalid | Windows 2012 R2 NVMe support (stornvme.sys) | ||
Description |
Is here anyway to get smartmontools to work on Windows 2012 R2 with nvme drive? This is what I'm seeing on the system. Microsoft Windows [Version 6.3.9600] (c) 2013 Microsoft Corporation. All rights reserved. C:\Windows\system32>smartctl --scan /dev/sda -d nvme # /dev/sda, NVMe device /dev/sdb -d nvme # /dev/sdb, NVMe device /dev/sdc -d nvme # /dev/sdc, NVMe device /dev/sdd -d nvme # /dev/sdd, NVMe device /dev/sde -d nvme # /dev/sde, NVMe device /dev/sdf -d scsi # /dev/sdf, SCSI device /dev/csmi6,3 -d ata # /dev/csmi6,3, ATA device C:\Windows\system32>smartctl -i /dev/sda smartctl 7.0 2018-12-30 r4883 [x86_64-w64-mingw32-2012r2] (sf-7.0-1) Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org Read NVMe Identify Controller failed: IOCTL_STORAGE_QUERY_PROPERTY(NVMe) failed, Error=1 C:\Windows\system32> |
|||
#711 | fixed | WDC WD4002FYYZ-01B7CB0 | ||
Description |
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.4.13-unRAID] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD4002FYYZ-01B7CB0 Serial Number: N8G8XKEY LU WWN Device Id: 5 000cca 244c40e30 Firmware Version: 01.01M02 User Capacity: 4,000,787,030,016 bytes [4.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Tue Jul 5 19:00:54 2016 BST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Disabled Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 113) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 571) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO-R-- 100 100 016 - 0 2 Throughput_Performance P-S--- 100 100 054 - 0 3 Spin_Up_Time POS--- 100 100 024 - 0 4 Start_Stop_Count -O--C- 100 100 000 - 1 5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0 7 Seek_Error_Rate PO-R-- 100 100 067 - 0 8 Seek_Time_Performance P-S--- 100 100 020 - 0 9 Power_On_Hours -O--C- 100 100 000 - 5 10 Spin_Retry_Count PO--C- 100 100 060 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 1 192 Power-Off_Retract_Count -O--CK 100 100 000 - 1 193 Load_Cycle_Count -O--C- 100 100 000 - 1 194 Temperature_Celsius -O---- 171 171 000 - 35 (Min/Max 25/39) 196 Reallocated_Event_Count -O--CK 100 100 000 - 0 197 Current_Pending_Sector -O---K 100 100 000 - 0 198 Offline_Uncorrectable ---R-- 100 100 000 - 0 199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x04 GPL,SL R/O 8 Device Statistics log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x08 GPL R/O 2 Power Conditions log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 SATA NCQ Queued Error log 0x11 GPL R/O 1 SATA Phy Event Counters log 0x12 GPL R/O 1 SATA NCQ NON-DATA log 0x15 GPL,SL R/W 1 SATA Rebuild Assist log 0x21 GPL R/O 1 Write stream error log 0x22 GPL R/O 1 Read stream error log 0x24 GPL R/O 256 Current Device Internal Status Data log 0x25 GPL R/O 256 Saved Device Internal Status Data log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 4 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 35 Celsius Power Cycle Min/Max Temperature: 25/39 Celsius Lifetime Min/Max Temperature: 25/39 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -40/70 Celsius Temperature History Size (Index): 128 (100) Index Estimated Time Temperature Celsius 101 2016-07-05 16:53 37 ****************** ... ..( 41 skipped). .. ****************** 15 2016-07-05 17:35 37 ****************** 16 2016-07-05 17:36 36 ***************** ... ..( 6 skipped). .. ***************** 23 2016-07-05 17:43 36 ***************** 24 2016-07-05 17:44 35 **************** ... ..( 74 skipped). .. **************** 99 2016-07-05 18:59 35 **************** 100 2016-07-05 19:00 37 ****************** SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) Page Offset Size Value Flags Description 0x01 ===== = = === == General Statistics (rev 2) == 0x01 0x008 4 1 --- Lifetime Power-On Resets 0x01 0x018 6 4889614016 --- Logical Sectors Written 0x01 0x020 6 4779089 --- Number of Write Commands 0x01 0x028 6 36510 --- Logical Sectors Read 0x01 0x030 6 699 --- Number of Read Commands 0x01 0x038 6 21420050 --- Date and Time TimeStamp 0x03 ===== = = === == Rotating Media Statistics (rev 1) == 0x03 0x008 4 5 --- Spindle Motor Power-on Hours 0x03 0x010 4 5 --- Head Flying Hours 0x03 0x018 4 1 --- Head Load Events 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors 0x03 0x028 4 0 --- Read Recovery Attempts 0x03 0x030 4 0 --- Number of Mechanical Start Failures 0x04 ===== = = === == General Errors Statistics (rev 1) == 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion 0x05 ===== = = === == Temperature Statistics (rev 1) == 0x05 0x008 1 35 --- Current Temperature 0x05 0x010 1 - N-- Average Short Term Temperature 0x05 0x018 1 - N-- Average Long Term Temperature 0x05 0x020 1 39 --- Highest Temperature 0x05 0x028 1 25 --- Lowest Temperature 0x05 0x030 1 - N-- Highest Average Short Term Temperature 0x05 0x038 1 - N-- Lowest Average Short Term Temperature 0x05 0x040 1 - N-- Highest Average Long Term Temperature 0x05 0x048 1 - N-- Lowest Average Long Term Temperature 0x05 0x050 4 0 --- Time in Over-Temperature 0x05 0x058 1 60 --- Specified Maximum Operating Temperature 0x05 0x060 4 0 --- Time in Under-Temperature 0x05 0x068 1 0 --- Specified Minimum Operating Temperature 0x06 ===== = = === == Transport Statistics (rev 1) == 0x06 0x008 4 0 --- Number of Hardware Resets 0x06 0x010 4 0 --- Number of ASR Events 0x06 0x018 4 0 --- Number of Interface CRC Errors |||_ C monitored condition met ||__ D supports DSN |___ N normalized value SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 1 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS |
|||
#1097 | fixed | please add the Cervoz Industrial SSD M305 (CIS 2S M305 64GB) | ||
Description |
Please add hhese HDD to your drivedb.h Cervoz_Industrial SSD M305 Family |
Note:
See TracQuery
for help on using queries.