Custom Query (1546 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (139 - 141 of 1546)

Ticket Resolution Summary Owner Reporter
#834 fixed Fix OS/2 support in the smartmontools Alex Samorukov
Description

Current status:

  1. Smartctl 5.37 is distributed within system (eCS 2.2). It is compiled by IBM VAC compiler according to the version info (i386-pc-ibmvac)
  2. Files os_os2.{cpp,h} were never properly integrated to the release and are missing in the autoconf and resulted targz. This should be easy to fix.
  3. File os_os2.cpp is very outdated and currently not compiling properly. It seems that it will need some efforts to compile.
  4. Smartmontools itself compiles under GCC/OS2 with some minimal autoconf tweaks and blames that application is not ported. Because of 2.

Todo:

  1. Include os_os* to the official tarball, and patch configure.ac and related files.
  2. fix os_os2.cpp to make it compile.
  3. Test it on VPC (at least -i should work)
  4. Ask someone to test it on a real hw.
  5. Update man and wiki
#836 wontfix SanDisk SDSSDP064G: Bogus Power_On_Hours raw value hreindl
Description

that device seems to be very special

Power_On_Hours 80 Filesystem created: Mon Jun 15 19:21:03 2015

smartmontools-6.2-7.el7.x86_64

i doubt the 80 hours because it's acting as router since it was installed and is 365/24 on :-)

Status /dev/sda:

smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.10.0-514.16.1.el7.x86_64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     SanDisk based SSDs
Device Model:     SanDisk SDSSDP064G
Serial Number:    151799401378
LU WWN Device Id: 5 001b44 e638807a2
Firmware Version: 3.2.0
User Capacity:    63.023.063.040 bytes [63,0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2 T13/2015-D revision 3
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Fri Apr 21 13:06:01 2017 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0002   100   100   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       -       80
 12 Power_Cycle_Count       0x0002   100   100   000    Old_age   Always       -       32
165 Total_Write/Erase_Count 0x0002   100   100   000    Old_age   Always       -       6104
171 Program_Fail_Count      0x0002   100   100   000    Old_age   Always       -       0
172 Erase_Fail_Count        0x0002   100   100   000    Old_age   Always       -       0
173 Avg_Write/Erase_Count   0x0002   100   100   000    Old_age   Always       -       1
174 Unexpect_Power_Loss_Ct  0x0002   100   100   000    Old_age   Always       -       20
187 Reported_Uncorrect      0x0002   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   079   021   000    Old_age   Always       -       21 (Min/Max 12/52)
230 Perc_Write/Erase_Count  0x0002   100   100   000    Old_age   Always       -       3
232 Perc_Avail_Resrvd_Space 0x0003   100   100   005    Pre-fail  Always       -       0
234 Perc_Write/Erase_Ct_BC  0x0002   100   100   000    Old_age   Always       -       5
241 Total_LBAs_Written      0x0002   100   100   000    Old_age   Always       -       224260420
242 Total_LBAs_Read         0x0002   100   100   000    Old_age   Always       -       56361752

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%        80         -
# 2  Short offline       Completed without error       00%        80         -
# 3  Short offline       Completed without error       00%        80         -
# 4  Short offline       Completed without error       00%        80         -
# 5  Short offline       Completed without error       00%        80         -
# 6  Short offline       Completed without error       00%        80         -
# 7  Extended offline    Completed without error       00%        80         -
# 8  Short offline       Completed without error       00%        80         -
# 9  Short offline       Completed without error       00%        79         -
#10  Short offline       Completed without error       00%        79         -
#11  Short offline       Completed without error       00%        79         -
#12  Short offline       Completed without error       00%        79         -
#13  Short offline       Completed without error       00%        79         -
#14  Short offline       Completed without error       00%        79         -
#15  Extended offline    Completed without error       00%        79         -
#16  Short offline       Completed without error       00%        78         -
#17  Short offline       Completed without error       00%        78         -
#18  Short offline       Completed without error       00%        78         -
#19  Short offline       Completed without error       00%        78         -
#20  Short offline       Completed without error       00%        78         -
#21  Short offline       Completed without error       00%        78         -
#837 duplicate Not in database: INTEL SSDSC2KW240H6 shulik
Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.