#777 | worksforme | Not in databse: HP MB4000GCWLV | ||
Description |
The HP storage modules 4 TB are not contained in the current drive database. Can you please add them? Many thanks in advance. |
|||
#778 | fixed | Seagate-ST8000VN0002-1Z8112 | ||
#779 | worksforme | SMART attribute 22 in WD RED drives | ||
Description |
Hi, Western Digital RED 8 TB version has SMART attribute 22 which seems to be lelated to helium filling. === START OF INFORMATION SECTION === Device Model: WDC WD80EFZX-68UW8N0 Serial Number: XXXXXX LU WWN Device Id: 5 000cca 3b7c6c38f Firmware Version: 83.H0A83 User Capacity: 8.001.563.222.016 bytes [8,00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 3.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Dec 16 11:22:12 2016 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 249) Self-test routine in progress... 90% of test remaining. Total time to complete Offline data collection: ( 101) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: (1083) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 131 131 054 Pre-fail Offline - 116 3 Spin_Up_Time 0x0007 100 100 024 Pre-fail Always - 0 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 1 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 128 128 020 Pre-fail Offline - 18 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 2 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1 22 Unknown_Attribute 0x0023 100 100 025 Pre-fail Always - 100 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 1 194 Temperature_Celsius 0x0002 181 181 000 Old_age Always - 33 (Min/Max 25/33) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged Maybe https://www.smartmontools.org/wiki/AttributesWestern-Digital can be updates as well... Thanky, Sebastian |
Note:
See TracQuery
for help on using queries.