#631 | fixed | Drive WDC WD4003FZEX needs to be added to smart database | ||
Description |
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.1.13-unRAID] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: WDC WD4003FZEX-00Z4SA0 Serial Number: WD-WCC130966733 LU WWN Device Id: 5 0014ee 25e2bd767 Firmware Version: 01.01A01 User Capacity: 4,000,787,030,016 bytes [4.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2 (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun Jan 10 16:18:42 2016 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (41640) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 451) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x7035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0 3 Spin_Up_Time POS--K 137 136 021 - 12125 4 Start_Stop_Count -O--CK 100 100 000 - 68 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0 7 Seek_Error_Rate -OSR-K 200 200 000 - 0 9 Power_On_Hours -O--CK 077 077 000 - 17417 10 Spin_Retry_Count -O--CK 100 253 000 - 0 11 Calibration_Retry_Count -O--CK 100 253 000 - 0 12 Power_Cycle_Count -O--CK 100 100 000 - 67 192 Power-Off_Retract_Count -O--CK 200 200 000 - 34 193 Load_Cycle_Count -O--CK 200 200 000 - 33 194 Temperature_Celsius -O---K 111 098 000 - 41 196 Reallocated_Event_Count -O--CK 200 200 000 - 0 197 Current_Pending_Sector -O--CK 200 200 000 - 0 198 Offline_Uncorrectable ----CK 200 200 000 - 0 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0 200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 5 Comprehensive SMART error log 0x03 GPL R/O 6 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x24 GPL R/O 1 Current Device Internal Status Data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log 0xa8-0xb7 GPL,SL VS 1 Device vendor specific log 0xbd GPL,SL VS 1 Device vendor specific log 0xc0 GPL,SL VS 1 Device vendor specific log 0xc1 GPL VS 93 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (6 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 17417 - # 2 Short offline Completed without error 00% 17416 - # 3 Short offline Completed without error 00% 12833 - # 4 Short offline Completed without error 00% 12332 - # 5 Short offline Completed without error 00% 11348 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 258 (0x0102) SCT Support Level: 1 Device State: Active (0) Current Temperature: 41 Celsius Power Cycle Min/Max Temperature: 36/42 Celsius Lifetime Min/Max Temperature: 18/54 Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 1 minute Temperature Logging Interval: 1 minute Min/Max recommended Temperature: 0/60 Celsius Min/Max Temperature Limit: -41/85 Celsius Temperature History Size (Index): 478 (247) Index Estimated Time Temperature Celsius 248 2016-01-10 08:21 41 ********************** ... ..(238 skipped). .. ********************** 9 2016-01-10 12:20 41 ********************** 10 2016-01-10 12:21 42 *********************** ... ..( 15 skipped). .. *********************** 26 2016-01-10 12:37 42 *********************** 27 2016-01-10 12:38 41 ********************** ... ..(219 skipped). .. ********************** 247 2016-01-10 16:18 41 ********************** SCT Error Recovery Control command not supported Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x8000 4 95739 Vendor specific |
|||
#632 | fixed | Not in smartctl database SAMSUNG-MZ7LN512HCHP | ||
Description |
My disk is not in smartctl database. Disk Vendor: SAMSUNG Disk Model: MZ7LN512HCHP Details: http://www.samsung.com/semiconductor/products/flash-storage/client-ssd/MZ7LN512HCHP # cat smartctl-SAMSUNG-MZ7LN512HCHP.txt smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.10.0-327.3.1.el7.x86_64] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SAMSUNG MZ7LN512HCHP-000L1 Serial Number: S1ZKNXAG835007 LU WWN Device Id: 5 002538 d00000000 Firmware Version: EMT04L0Q User Capacity: 512,110,190,592 bytes [512 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Wed Jan 13 20:50:46 2016 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, frozen [SEC2] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 265) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0 9 Power_On_Hours -O--CK 099 099 000 - 139 12 Power_Cycle_Count -O--CK 099 099 000 - 40 170 Unknown_Attribute -O--CK 100 100 010 - 0 171 Unknown_Attribute -O--CK 100 100 010 - 0 172 Unknown_Attribute -O--CK 100 100 010 - 0 173 Unknown_Attribute PO--CK 099 099 005 - 2 174 Unknown_Attribute -O--CK 099 099 000 - 9 178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0 180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 1567 184 End-to-End_Error PO--CK 100 100 097 - 0 187 Reported_Uncorrect -O--CK 100 100 000 - 0 194 Temperature_Celsius -O--CK 057 048 000 - 43 199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0 233 Media_Wearout_Indicator PO--C- 099 099 000 - 16760437 241 Total_LBAs_Written -O--CK 099 099 000 - 638 242 Total_LBAs_Read -O--CK 099 099 000 - 402 249 Unknown_Attribute -O--CK 099 099 000 - 1024 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 SL R/O 1 Summary SMART error log 0x02 SL R/O 1 Comprehensive SMART error log 0x03 GPL R/O 1 Ext. Comprehensive SMART error log 0x06 SL R/O 1 SMART self-test log 0x07 GPL R/O 1 Extended self-test log 0x09 SL R/W 1 Selective self-test log 0x10 GPL R/O 1 NCQ Command Error log 0x11 GPL R/O 1 SATA Phy Event Counters 0x13 GPL R/O 1 SATA NCQ Send and Receive log 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log 0x80-0x9f GPL,SL R/W 16 Host vendor specific log 0xdf GPL,SL VS 1 Device vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log Version: 1 (1 sectors) No Errors Logged SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 138 - # 2 Short offline Completed without error 00% 136 - Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum. SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 255 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. SCT Status Version: 3 SCT Version (vendor specific): 256 (0x0100) SCT Support Level: 1 Device State: Active (0) Current Temperature: 44 Celsius Power Cycle Min/Max Temperature: 35/51 Celsius Lifetime Min/Max Temperature: 0/70 Celsius Under/Over Temperature Limit Count: 4294967295/4294901760 SCT Temperature History Version: 3 (Unknown, should be 2) Temperature Sampling Period: 1 minute Temperature Logging Interval: 10 minutes Min/Max recommended Temperature: 0/70 Celsius Min/Max Temperature Limit: 0/70 Celsius Temperature History Size (Index): 128 (42) Index Estimated Time Temperature Celsius 43 2016-01-12 23:40 38 ******************* 44 2016-01-12 23:50 38 ******************* 45 2016-01-13 00:00 38 ******************* 46 2016-01-13 00:10 37 ****************** 47 2016-01-13 00:20 37 ****************** 48 2016-01-13 00:30 36 ***************** ... ..( 57 skipped). .. ***************** 106 2016-01-13 10:10 36 ***************** 107 2016-01-13 10:20 37 ****************** ... ..( 2 skipped). .. ****************** 110 2016-01-13 10:50 37 ****************** 111 2016-01-13 11:00 38 ******************* ... ..( 10 skipped). .. ******************* 122 2016-01-13 12:50 38 ******************* 123 2016-01-13 13:00 40 ********************* 124 2016-01-13 13:10 39 ******************** 125 2016-01-13 13:20 38 ******************* 126 2016-01-13 13:30 37 ****************** 127 2016-01-13 13:40 37 ****************** 0 2016-01-13 13:50 38 ******************* ... ..( 4 skipped). .. ******************* 5 2016-01-13 14:40 38 ******************* 6 2016-01-13 14:50 37 ****************** 7 2016-01-13 15:00 38 ******************* ... ..( 11 skipped). .. ******************* 19 2016-01-13 17:00 38 ******************* 20 2016-01-13 17:10 39 ******************** ... ..( 5 skipped). .. ******************** 26 2016-01-13 18:10 39 ******************** 27 2016-01-13 18:20 38 ******************* ... ..( 3 skipped). .. ******************* 31 2016-01-13 19:00 38 ******************* 32 2016-01-13 19:10 39 ******************** 33 2016-01-13 19:20 38 ******************* ... ..( 5 skipped). .. ******************* 39 2016-01-13 20:20 38 ******************* 40 2016-01-13 20:30 39 ******************** 41 2016-01-13 20:40 51 ******************************** 42 2016-01-13 20:50 44 ************************* SCT Error Recovery Control: Read: Disabled Write: Disabled Device Statistics (GP Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 4 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC |
|||
#634 | wontfix | Do not operate on drives which are security locked by password | ||
Description |
The following is not me, but it's fairly similar: https://bbs.archlinux.org/viewtopic.php?id=178554 scsiModePageOffset: response length too short, resp_len=xx offset=yy bd_len=zz Well after I got this message when trying to do a smartctl long test, I thought my drive was faulty as this guy's one was, but it was 100% OK. The actual reason for the "error" was almost to be called hilarious: my drive was security locked! This happened after using security erase (enhanced) via hdparm: # hdparm --user-master u --security-set-pass /dev/sdc blahdiblah # hdparm --user-master u --security-erase enhanced /dev/sdc blahdiblah It may be a bug in hdparm that it doesn't always release the lock as soon as it has finished erasing. Anyways, that "faulty" drive was actually a great drive, and after doing a DISPWD on it via MHDD, it gave me a PERFECT rating on HDD Sentinel. tl;dr ? What this enhancement request is about:
|