#745 | fixed | Add Samsung PM871a | ||
Description |
It's not in our database. It's a successor to the PM871. smartctl 6.6 2016-09-25 r4345 [x86_64-linux-3.10.0-327.36.1.el7.x86_64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SAMSUNG MZ7LN256HMJP-00000 Serial Number: S2MJNX0H403606 LU WWN Device Id: 5 002538 d40cd8db4 Firmware Version: MAV0100Q User Capacity: 256,060,514,304 bytes [256 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Mon Sep 26 23:28:59 2016 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x53) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 133) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 1450 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 3 170 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0 171 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 010 Old_age Always - 0 173 Unknown_Attribute 0x0033 099 099 005 Pre-fail Always - 1 174 Unknown_Attribute 0x0032 099 099 000 Old_age Always - 1 178 Used_Rsvd_Blk_Cnt_Chip 0x0013 100 100 010 Pre-fail Always - 0 180 Unused_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 820 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0032 065 064 000 Old_age Always - 35 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 233 Media_Wearout_Indicator 0x0013 099 099 000 Pre-fail Always - 16763233 241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 355 242 Total_LBAs_Read 0x0032 099 099 000 Old_age Always - 3 249 Unknown_Attribute 0x0032 099 099 000 Old_age Always - 355 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 3 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing 255 0 65535 Read_scanning was never started Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. |
|||
#747 | fixed | SanDisk SD7SN6S-512G-1006 | ||
Description |
SanDisk SD7SN6S-(128|256|512)G-1006 OEM Version of the SanDisk X300: kb.sandisk.com/app/answers/detail/a_id/19208/~/sandisk-x300-ssd-firmware-update |
|||
#750 | fixed | New SSD drive for database: Intel SSD DC S3520 Series 240GB | ||
Description |
Intel SSDSC2BB240G7 Links: http://www.intel.com/content/www/us/en/solid-state-drives/solid-state-drives-dc-s3520-series.html http://ark.intel.com/products/93012/Intel-SSD-DC-S3520-Series-240GB-2_5in-SATA-6Gbs-3D1-MLC |
Note: