Custom Query (1363 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (166 - 168 of 1363)

Ticket Resolution Summary Owner Reporter
#482 fixed Support for Prolific PL2773 Christian Franke TomVe
Description

The ICY BOX IB-120StU3 uses a Prolific PL2773 chip, which is currently not supported by smartmontools. By reverse engineering the Windows tool iSmart.exe i have made the included patch. It seems to work well and supports all of smartctl -a.

Please review and consider including in your next release.

#490 fixed Add ADATA SSD SX900 512GB-DL2 Christian Franke spacedust
Description

Please add ADATA SSD SX900

smartctl 6.3 2014-07-26 r3976 [x86_64-w64-mingw32-win7-sp1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     ADATA SSD SX900 512GB-DL2
Serial Number:    7D4120008765
LU WWN Device Id: 0 000000 000000000
Firmware Version: 5.8.2
User Capacity:    512 110 190 592 bytes [512 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS, ACS-2 T13/2015-D revision 3
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sat Nov 08 19:37:14 2014
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed

                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7d) SMART execute Offline immediate.
                                        No Auto Offline data collection support.

                                        Abort Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  48) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x0025) SCT Status supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_
FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0032   120   120   050    Old_age   Always       -
       1541893259264
  5 Reallocated_Sector_Ct   0x0033   075   075   003    Pre-fail  Always       -
       12
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -
       7 (213 126 0)
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -
       25
171 Unknown_Attribute       0x000a   100   100   000    Old_age   Always       -
       0
172 Unknown_Attribute       0x0032   100   100   000    Old_age   Always       -
       0
174 Unknown_Attribute       0x0030   000   000   000    Old_age   Offline      -
       14
177 Wear_Leveling_Count     0x0000   000   000   000    Old_age   Offline      -
       0
181 Program_Fail_Cnt_Total  0x000a   100   100   000    Old_age   Always       -
       0
182 Erase_Fail_Count_Total  0x0032   100   100   000    Old_age   Always       -
       0
187 Reported_Uncorrect      0x0012   001   001   000    Old_age   Always       -
       46252
194 Temperature_Celsius     0x0022   028   053   000    Old_age   Always       -
       28 (Min/Max 13/53)
195 Hardware_ECC_Recovered  0x001c   120   120   000    Old_age   Offline      -
       1541893259264
196 Reallocated_Event_Count 0x0033   075   075   003    Pre-fail  Always       -
       12
201 Unknown_SSD_Attribute   0x001c   120   120   000    Old_age   Offline      -
       1541893259264
204 Soft_ECC_Correction     0x001c   120   120   000    Old_age   Offline      -
       1541893259264
230 Unknown_SSD_Attribute   0x0013   100   100   000    Pre-fail  Always       -
       100
231 Temperature_Celsius     0x0013   073   073   010    Pre-fail  Always       -
       180388626433
233 Media_Wearout_Indicator 0x0032   000   000   000    Old_age   Always       -
       374
234 Unknown_Attribute       0x0032   000   000   000    Old_age   Always       -
       831
241 Total_LBAs_Written      0x0032   000   000   000    Old_age   Always       -
       831
242 Total_LBAs_Read         0x0032   000   000   000    Old_age   Always       -
       511

SMART Error Log not supported

SMART Self-test log structure revision number 0
Warning: ATA Specification requires self-test log structure revision number = 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
#496 fixed Add support for aacraid PMC(Adaptec) raid controller for windows Christian Franke nidhi
Description

To add support for aacraid PMC(Adaptec) for windows.currently,we have support only for linux OS we would like to extend it for windows OS as well.We need your help and support in this regard

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.