Custom Query (1414 matches)
Results (166 - 168 of 1414)
Ticket | Resolution | Summary | Owner | Reporter |
---|---|---|---|---|
#482 | fixed | Support for Prolific PL2773 | ||
Description |
The ICY BOX IB-120StU3 uses a Prolific PL2773 chip, which is currently not supported by smartmontools. By reverse engineering the Windows tool iSmart.exe i have made the included patch. It seems to work well and supports all of smartctl -a. Please review and consider including in your next release. |
|||
#490 | fixed | Add ADATA SSD SX900 512GB-DL2 | ||
Description |
Please add ADATA SSD SX900 smartctl 6.3 2014-07-26 r3976 [x86_64-w64-mingw32-win7-sp1] (sf-6.3-1) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: ADATA SSD SX900 512GB-DL2 Serial Number: 7D4120008765 LU WWN Device Id: 0 000000 000000000 Firmware Version: 5.8.2 User Capacity: 512 110 190 592 bytes [512 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS, ACS-2 T13/2015-D revision 3 SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sat Nov 08 19:37:14 2014 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x7d) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x0025) SCT Status supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_ FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0032 120 120 050 Old_age Always - 1541893259264 5 Reallocated_Sector_Ct 0x0033 075 075 003 Pre-fail Always - 12 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 7 (213 126 0) 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 25 171 Unknown_Attribute 0x000a 100 100 000 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 174 Unknown_Attribute 0x0030 000 000 000 Old_age Offline - 14 177 Wear_Leveling_Count 0x0000 000 000 000 Old_age Offline - 0 181 Program_Fail_Cnt_Total 0x000a 100 100 000 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0032 100 100 000 Old_age Always - 0 187 Reported_Uncorrect 0x0012 001 001 000 Old_age Always - 46252 194 Temperature_Celsius 0x0022 028 053 000 Old_age Always - 28 (Min/Max 13/53) 195 Hardware_ECC_Recovered 0x001c 120 120 000 Old_age Offline - 1541893259264 196 Reallocated_Event_Count 0x0033 075 075 003 Pre-fail Always - 12 201 Unknown_SSD_Attribute 0x001c 120 120 000 Old_age Offline - 1541893259264 204 Soft_ECC_Correction 0x001c 120 120 000 Old_age Offline - 1541893259264 230 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 100 231 Temperature_Celsius 0x0013 073 073 010 Pre-fail Always - 180388626433 233 Media_Wearout_Indicator 0x0032 000 000 000 Old_age Always - 374 234 Unknown_Attribute 0x0032 000 000 000 Old_age Always - 831 241 Total_LBAs_Written 0x0032 000 000 000 Old_age Always - 831 242 Total_LBAs_Read 0x0032 000 000 000 Old_age Always - 511 SMART Error Log not supported SMART Self-test log structure revision number 0 Warning: ATA Specification requires self-test log structure revision number = 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. |
|||
#496 | fixed | Add support for aacraid PMC(Adaptec) raid controller for windows | ||
Description |
To add support for aacraid PMC(Adaptec) for windows.currently,we have support only for linux OS we would like to extend it for windows OS as well.We need your help and support in this regard |
Note:
See TracQuery