Custom Query (1566 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (124 - 126 of 1566)

Ticket Resolution Summary Owner Reporter
#239 fixed Firmware warning for more Seagate drives Christian Franke maharaja
Description

there are a couple of other seagate drives that are also affected by firmware bugs, for example "​Seagate Barracuda 7200.12":

Please refer to ​Firmware Updates for Seagate Products for a more complete list.

It would be nice to integrate the corresponding checks into smartd.

#251 worksforme smartctl segfaults on OpenBSD-powerpc Christian Franke gbechis
Description

On OpenBSD-current @powerpc smartctl 6.0 segfaults, here there are some info:

$ sudo smartctl -i /dev/wd0c smartctl 6.0 2012-10-10 r3643 [powerpc-unknown-openbsd5.2] (local build) Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org

Segmentation fault (core dumped)


Program received signal SIGSEGV, Segmentation fault. strcmp (s1=0xfffd5403 "ec2hour", s2=0x20436f6d <Address 0x20436f6d out of bounds>) at /usr/src/lib/libc/string/strcmp.c:47 47 while (*s1 == *s2++) Current language: auto; currently c (gdb) bt #0 strcmp (s1=0xfffd5403 "ec2hour", s2=0x20436f6d <Address 0x20436f6d out of bounds>) at /usr/src/lib/libc/string/strcmp.c:47 #1 0x0180bd54 in parse_attribute_def (opt=Variable "opt" is not available. ) at /usr/obj/ports/smartmontools-6.0/smartmontools-6.0/atacmds.cpp:213 #2 0x0181bf7c in parse_db_presets (presets=0x18588c4 "-v 9,seconds", defs=0xfffd5620, firmwarebugs=0xfffd7858, type=0x0)

at

/usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 #3 0x0181bf7c in parse_db_presets (presets=0xfffd7858 "", defs=0x0, firmwarebugs=0x0, type=0xfffd8269)

at

/usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 #4 0x0181bf7c in parse_db_presets (presets=0xffffffff <Address 0xffffffff out of bounds>, defs=0x30303800, firmwarebugs=0xf8c69177, type=0x1c00)

at

/usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 #5 0x0181bf7c in parse_db_presets (presets=0x0, defs=0x0, firmwarebugs=0x17, type=0xfffda354) at /usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 #6 0x0181bf7c in parse_db_presets (presets=0x1890e1c "\001\210\r
", defs=0x5, firmwarebugs=0x24000022, type=0x18a0f30)

at

/usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 #7 0x0181bf7c in parse_db_presets (presets=0x20 <Address 0x20 out of bounds>, defs=0x1890e1c, firmwarebugs=0xfffda404, type=0xfffda3b0)

at

/usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 #8 0x0181bf7c in parse_db_presets (presets=0x0, defs=0x20, firmwarebugs=0x1801eb0, type=0x1890e18)

at

/usr/obj/ports/smartmontools-6.0/smartmontools-6.0/knowndrives.cpp:221 Previous frame inner to this frame (corrupt stack?)

#257 fixed Intel 320 40GB SSD not recognized Christian Franke spork999
Description

Hello,

We have a few Intel 320 SSDs of various sizes. They are all recognized in smartmontools 5.4.3 with a current drivedb.h with the exception of our 40GB models.

Below is output from a 40GB that's not recognized. Please let me know if you require further information to get this drive in the database. It appears this line in drivedb.h is missing a possible match:

"INTEL SSDSA[12]C[WT](040|080|120|160|300|600)G3"

SSDSA2BT040G3

This line seems to work:

"INTEL SSDSA[12][BC][WT](040|080|120|160|300|600)G3"

40GB output before:

smartctl 5.43 2012-06-30 r3573 [FreeBSD 8.3-STABLE amd64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     INTEL SSDSA2BT040G3
Serial Number:    CVPR210300YJ040AGN
LU WWN Device Id: 5 001517 bb28758fb
Firmware Version: 4PC10362
User Capacity:    40,020,664,320 bytes [40.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Fri Jan 11 05:01:08 2013 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

And after:

root@k29:/home/spork # smartctl -a /dev/ada4 | more
smartctl 5.43 2012-06-30 r3573 [FreeBSD 8.3-STABLE amd64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Intel 320 Series SSDs
Device Model:     INTEL SSDSA2BT040G3
Serial Number:    CVPR210300YJ040AGN
LU WWN Device Id: 5 001517 bb28758fb
Firmware Version: 4PC10362
User Capacity:    40,020,664,320 bytes [40.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Fri Jan 11 05:03:12 2013 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (    1) seconds.
Offline data collection
capabilities:                    (0x75) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Abort Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   1) minutes.
Conveyance self-test routine
recommended polling time:        (   1) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 5
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  3 Spin_Up_Time            0x0020   100   100   000    Old_age   Offline      -       0
  4 Start_Stop_Count        0x0030   100   100   000    Old_age   Offline      -       0
  5 Reallocated_Sector_Ct   0x0032   100   100   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       3754
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       28
170 Reserve_Block_Count     0x0033   100   100   010    Pre-fail  Always       -       0
171 Program_Fail_Count      0x0032   100   100   000    Old_age   Always       -       0
172 Erase_Fail_Count        0x0032   100   100   000    Old_age   Always       -       0
183 Runtime_Bad_Block       0x0030   100   100   000    Old_age   Offline      -       0
184 End-to-End_Error        0x0032   100   100   090    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
192 Unsafe_Shutdown_Count   0x0032   100   100   000    Old_age   Always       -       22
199 UDMA_CRC_Error_Count    0x0030   100   100   000    Old_age   Offline      -       0
225 Host_Writes_32MiB       0x0032   100   100   000    Old_age   Always       -       24139
226 Workld_Media_Wear_Indic 0x0032   100   100   000    Old_age   Always       -       676
227 Workld_Host_Reads_Perc  0x0032   100   100   000    Old_age   Always       -       1
228 Workload_Minutes        0x0032   100   100   000    Old_age   Always       -       225293
232 Available_Reservd_Space 0x0033   100   100   010    Pre-fail  Always       -       0
233 Media_Wearout_Indicator 0x0032   100   100   000    Old_age   Always       -       0
241 Host_Writes_32MiB       0x0032   100   100   000    Old_age   Always       -       24139
242 Host_Reads_32MiB        0x0032   100   100   000    Old_age   Always       -       356

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.