#150 | fixed | Adding scterc set command to smartd | ||
Description |
Please add scterc set command to smartd if possible |
|||
#153 | fixed | missing USB bridge for LaCie Drive | ||
Description |
[root@davedina ~]# smartctl --all /dev/sde -d auto smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net /dev/sde: Unknown USB bridge [0x059f:0x1029 (0x100)] Smartctl: please specify device type with the -d option. Use smartctl -h to get a usage summary [root@davedina ~]# smartctl --all /dev/sde -d sat smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net START OF INFORMATION SECTIONModel Family: Hitachi Deskstar 7K2000 Device Model: Hitachi HDS722020ALA330 Serial Number: JK1121YAG4220S Firmware Version: JKAOA10D User Capacity: 2,000,398,934,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Fri Mar 4 16:45:52 2011 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled START OF READ SMART DATA SECTIONSMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x84) Offline data collection activity
Self-test execution status: ( 0) The previous self-test routine completed
Total time to complete Offline data collection: (22036) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate.
SMART capabilities: (0x0003) Saves SMART data before entering
Error logging capability: (0x01) Error logging supported.
Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 255) minutes. SCT capabilities: (0x003d) SCT Status supported.
SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 56 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 56 194 Temperature_Celsius 0x0002 253 253 000 Old_age Always - 21 (Min/Max 17/58) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 0 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1
Selective self-test flags (0x0):
If Selective self-test is pending on power-up, resume after 0 minute delay. Works with SAT, so I think you can add it safely. |
|||