#1671 | invalid | New Disk Kingston Data Center DC1500M | ||
Description |
This disk is not in the Database Kingston Data Center DC1500M |
|||
#1665 | fixed | WDC WD80EFZZ | ||
Description |
Western Digital Red Plus 8TB (CMR) |
|||
#1664 | fixed | Problem with Patriot Burst 480GB Unknown_SSD_Attribute | ||
Description |
=== START OF INFORMATION SECTION === Device Model: Patriot Burst 480GB Serial Number: 519307220B5D00360815 Firmware Version: SBFMLA.5 User Capacity: 480,103,981,056 bytes [480 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (65535) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 30) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 2949 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 20 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 170 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 260 173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 1179726 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 16 194 Temperature_Celsius 0x0023 067 067 000 Pre-fail Always - 33 (Min/Max 33/33) 218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0 231 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 99 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 3209 SMART Error Log Version: 1 No Errors Logged |
Note:
See TracQuery
for help on using queries.