Custom Query (1566 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (10 - 12 of 1566)

← 1 2 3 4 5 6 7 8 9 10 11 12 13 14 →
Ticket Resolution Summary Owner Reporter
#1984 fixed Add to drivedb: PNY CS900 250GB SSD Andrei Ivanov
Description

Request to add a slightly larger capacity PNY CS900 SSD to drivedb. Smartctl output attached.

The patch:

--- drivedb.h.20260314  2026-03-14 11:06:00.000000000 -0600
+++ drivedb.h   2026-03-16 13:22:07.314158398 -0600
@@ -1113,8 +1113,9 @@
       // Patriot Blaze/S9FM02, Patriot Flare/SBFM91.2, Patriot Ignite/SAFM01.7
     "Patriot Burst( (120|240|480|960)GB)?|" // tested with Patriot Burst/SBFM11.2,
       // Patriot Burst 480GB/SBFMLA.5
-    "PNY CS(900|1311|2211) ((12|24|48|50|96)0G|[12]T)B SSD|" // tested with PNY CS900 120GB SSD/CS900612,
-      // PNY CS900 240GB SSD/CS900613, PNY CS900 500GB SSD/CS900LA5, PNY CS900 500GB SSD/CS900Y13,
+    "PNY CS(900|1311|2211) ((12|2[45]|48|50|96)0G|[12]T)B SSD|" // tested with
+      // PNY CS900 120GB SSD/CS900612, PNY CS900 240GB SSD/CS900613,
+      // PNY CS900 250GB SSD/CS900E00, PNY CS900 500GB SSD/CS900LA5, PNY CS900 500GB SSD/CS900Y13,
       // PNY CS900 1TB SSD/CS900615, PNY CS1311 120GB SSD/CS131122, PNY CS2211 240GB SSD/CS221016
     "PNY ELITE PSSD|" // tested with PNY ELITE PSSD/CS105P13 (240G)
     "S11-(128|256|512)G-PHISON-SSD-B27|" // tested with: S11-512G-PHISON-SSD-B27/SBFMJ1.3
#1981 fixed Please add Foresee S58A SSD to the database Cmdr_Zod
Description

This is an M.2 2280 SATA Drive, also available in 2.5" in 128GB, 256GB, 1TB and TB according to the ​Product catalogue. Data sheet for the M.2 version is located at ​https://datasheet.lcsc.com/lcsc/2008181906_FORESEE-FSGSCOC-512G_C719935.pdf and specifies capacities from 128GB to 1TB for the M.2 version.

SMART Data vendor-specific attributes per data sheet (some seem to be default)

Attribute ID (hex) Attribute Name
05 New Bad Block Count
09 Power On Hours
0C Power Cycle Count
A7 Average Erase Count
A8 SATA PHY Error Count
A9 Bad Block Count
AB Program Fail Count
AC Erase Fail Count
AD Erase Count
AF Bad Cluster Count
B1 Read Retry Count
B4 Spare Block Count Left
BB Uncorrectable Error Count
C0 Unexpected Power Loss Count
C2 Temperature
C7 UltraDMA CRC Error Count
CE Minimum Erase Count
CF Maximum Erase Count
D0 Average Erase Count
D1 SLC Minimum Erase Count
D2 SLC Maximum Erase Count
D3 SLC Average Erase Count
E7 SSD Life Left
F1 Total LBA written
F2 Total LBA read

PN of my Model is: FSGSCOC-512G There is also a second product designation: S58AF512G

The controller is labeled as: FORESEE DM918 QT724 2103

I couldn't find any information about this controller. Running a short SMART test on the drive seems to never finish when idle (it will report 90% remaining all the time), I ended up writing zeros to the whole drive in an attempt to see if it helps, and at some point the SMART test finished.

Please find attached the output of smartctl -x /dev/sdX

#1980 wontfix SanDisk Cruzer Fit unknown usb [0x0781:0x5571 (0x126)] Cristobal
Description

Hi,

device to add to database

/dev/sda: Unknown USB bridge [0x0781:0x5571 (0x126)]

Thanks

← 1 2 3 4 5 6 7 8 9 10 11 12 13 14 →
Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.