Custom Query (1458 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (55 - 57 of 1458)

Ticket Resolution Summary Owner Reporter
#1846 worksforme WDC WD40EZAZ-00SF3B0 Frank Esposito
Description

New Drive WDC WD40EZAZ-00SF3B0

#1844 invalid SanDisk UltraFit USB 3.2 Gen1 Flash Drive 32GB PhilBro
Description

Error received below. Please add drive to database

/dev/sde: Unknown USB bridge [0x0781:0x5583 (0x100)]

#1841 fixed Add RTL9201R based Orico enclosure to DB (0x0bda:0x9201) Christian Franke Adam
Description

Hi,

I'm using Orico 9606C3 enclosure to for M.2 Sata devices. Without any options the smartctl throws an error:

root@nas:/srv# smartctl  -a /dev/sde
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-18-amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org

/dev/sde: Unknown USB bridge [0x0bda:0x9201 (0xf200)]
Please specify device type with the -d option.

Use smartctl -h to get a usage summary

However with -d sat option everything works way better.

root@nas:/srv# smartctl -d sat -a /dev/sde
smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-18-amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SPCC M.2 SSD
Serial Number:    AA2022021280002432
Firmware Version: U1209A0
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
TRIM Command:     Available
Device is:        Not in smartctl database 7.3/5610
ATA Version is:   ACS-3 T13/2161-D revision 4
SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 1.5 Gb/s)
Local Time is:    Sun Jun 16 22:36:51 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (  120) seconds.
Offline data collection
capabilities:                    (0x11) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0002) Does not save SMART data before
                                        entering power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  10) minutes.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0032   100   100   050    Old_age   Always       -       0
  5 Reallocated_Sector_Ct   0x0032   100   100   050    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   100   100   050    Old_age   Always       -       425
 12 Power_Cycle_Count       0x0032   100   100   050    Old_age   Always       -       64
160 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       0
161 Unknown_Attribute       0x0033   100   100   050    Pre-fail  Always       -       100
163 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       9
164 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       152
165 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       2
166 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       1
167 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       1
168 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       5050
169 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       100
175 Program_Fail_Count_Chip 0x0032   100   100   050    Old_age   Always       -       0
176 Erase_Fail_Count_Chip   0x0032   100   100   050    Old_age   Always       -       0
177 Wear_Leveling_Count     0x0032   100   100   050    Old_age   Always       -       0
178 Used_Rsvd_Blk_Cnt_Chip  0x0032   100   100   050    Old_age   Always       -       0
181 Program_Fail_Cnt_Total  0x0032   100   100   050    Old_age   Always       -       0
182 Erase_Fail_Count_Total  0x0032   100   100   050    Old_age   Always       -       0
192 Power-Off_Retract_Count 0x0032   100   100   050    Old_age   Always       -       48
194 Temperature_Celsius     0x0022   100   100   050    Old_age   Always       -       40
195 Hardware_ECC_Recovered  0x0032   100   100   050    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   100   100   050    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   100   100   050    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0032   100   100   050    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x0032   100   100   050    Old_age   Always       -       0
232 Available_Reservd_Space 0x0032   100   100   050    Old_age   Always       -       100
241 Total_LBAs_Written      0x0030   100   100   050    Old_age   Offline      -       2418
242 Total_LBAs_Read         0x0030   100   100   050    Old_age   Offline      -       621
245 Unknown_Attribute       0x0032   100   100   050    Old_age   Always       -       683

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%         8         -
# 2  Extended offline    Completed without error       00%         7         -
# 3  Extended offline    Aborted by host               10%         7         -
# 4  Extended offline    Aborted by host               80%         7         -
# 5  Short offline       Completed without error       00%         0         -
# 6  Short offline       Aborted by host               80%         0         -

Selective Self-tests/Logging not supported

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.