#1827 duplicate Read Self-test Log failed: Invalid Field in Command (0x4002) Artem S. Tashkinov
Description

smartctl 7.4 2023-08-01 r5530 fails to read the Self-test Log and seemingly fails to start any short/long self tests with the same error.

Sorry if it's already been reported but I've not been able to find any similar reports.

My device is:

Model Number: WD_BLACK SN770 1TB Firmware Version: 731100WD

#1824 wontfix Change the capability name of "Offline surface scan" to "Off-line Read Scanning" jay
Description

This is listed in the capabilities section when using smartctl --capabilities command.

It is called Off-line Read Scanning in this draft of ACS-3, page 264, Table 133, Bit 3: https://people.freebsd.org/~imp/asiabsdcon2015/works/d2161r5-ATAATAPI_Command_Set_-_3.pdf

And I can find a few manuals of drives that use the name Off-line Read Scanning: https://documents.westerndigital.com/content/dam/doc-library/en_us/assets/public/western-digital/product/data-center-drives/ultrastar-dc-hc500-series/product-manual-ultrastar-dc-hc550-sata-oem-spec.pdf page 306, 12.53.2.6 Off-Line Data Collection Capability, Bit 3 https://ia804502.us.archive.org/14/items/manualzilla-id-7035037/7035037.pdf page 149, 14.39.2.7 Off-Line Data Collection Capability, Bit 3 http://datasheet.elcodis.com/pdf2/99/55/995536/mmdoe28gxmsp-0va.pdf page 27, 7.3.2.7 Off-line data collection capability, Bit 3

Using the same name as these documents will make searching for information easier.

#1821 fixed New drive: Toshiba Canvio Flex 4TB (TOSHIBA MQ04UBB400, 0x0480:0xa301) Christian Franke hmijail
Description

https://www.toshiba-storage.com/products/canvio-flex/

Scanned in macOS with the SAT driver

smartctl 7.4 2023-08-01 r5530 [Darwin 23.4.0 arm64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MQ04UBB400
Firmware Version: JS0B0U
User Capacity:    4,000,787,030,016 bytes [4.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Zoned Device:     Device managed zones
Device is:        Not in smartctl database 7.3/5528
ATA Version is:   ACS-3 T13/2161-D revision 5
SATA Version is:  SATA 3.3, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Apr  2 19:46:47 2024 AEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM level is:     128 (minimum power consumption without standby)
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Disabled
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unknown

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  120) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 ( 665) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO-R--   100   100   050    -    0
  2 Throughput_Performance  P-S---   100   100   050    -    0
  3 Spin_Up_Time            POS--K   100   100   001    -    5144
  4 Start_Stop_Count        -O--CK   100   100   000    -    11
  5 Reallocated_Sector_Ct   PO--CK   100   100   050    -    0
  7 Seek_Error_Rate         PO-R--   100   100   050    -    0
  8 Seek_Time_Performance   P-S---   100   100   050    -    0
  9 Power_On_Hours          -O--CK   100   100   000    -    1
 10 Spin_Retry_Count        PO--CK   100   100   030    -    0
 12 Power_Cycle_Count       -O--CK   100   100   000    -    5
191 G-Sense_Error_Rate      -O--CK   100   100   000    -    0
192 Power-Off_Retract_Count -O--CK   100   100   000    -    0
193 Load_Cycle_Count        -O--CK   100   100   000    -    19
194 Temperature_Celsius     -O---K   100   100   000    -    32 (Min/Max 23/32)
196 Reallocated_Event_Count -O--CK   100   100   000    -    0
197 Current_Pending_Sector  -O--CK   100   100   000    -    0
198 Offline_Uncorrectable   ----CK   100   100   000    -    0
199 UDMA_CRC_Error_Count    -O--CK   200   200   000    -    0
220 Disk_Shift              -O----   100   100   000    -    0
222 Loaded_Hours            -O--CK   100   100   000    -    0
223 Load_Retry_Count        -O--CK   100   100   000    -    0
224 Load_Friction           -O---K   100   100   000    -    0
226 Load-in_Time            -OS--K   100   100   000    -    263
240 Head_Flying_Hours       P-----   100   100   001    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
Read GP Log Directory failed

SMART Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00           SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O     51  Comprehensive SMART error log
0x04           SL  R/O      8  Device Statistics log
0x06           SL  R/O      1  SMART self-test log
0x09           SL  R/W      1  Selective self-test log
0x30           SL  R/O      9  IDENTIFY DEVICE data log
0x80-0x9f      SL  R/W     16  Host vendor specific log
0xe0           SL  R/W      1  SCT Command/Status
0xe1           SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log Version: 1
No Errors Logged

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%         1         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       1 (0x0001)
Device State:                        Active (0)
Current Temperature:                    32 Celsius
Power Cycle Min/Max Temperature:     28/32 Celsius
Lifetime    Min/Max Temperature:     23/32 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        1 minute
Min/Max recommended Temperature:      0/60 Celsius
Min/Max Temperature Limit:            0/60 Celsius
Temperature History Size (Index):    478 (38)

Index    Estimated Time   Temperature Celsius
  39    2024-04-02 11:49     ?  -
 ...    ..(439 skipped).    ..  -
   1    2024-04-02 19:09     ?  -
   2    2024-04-02 19:10    27  ********
   3    2024-04-02 19:11    27  ********
   4    2024-04-02 19:12    27  ********
   5    2024-04-02 19:13    28  *********
   6    2024-04-02 19:14     ?  -
   7    2024-04-02 19:15    28  *********
   8    2024-04-02 19:16    28  *********
   9    2024-04-02 19:17    29  **********
  10    2024-04-02 19:18    29  **********
  11    2024-04-02 19:19     ?  -
  12    2024-04-02 19:20    29  **********
  13    2024-04-02 19:21    29  **********
  14    2024-04-02 19:22    29  **********
  15    2024-04-02 19:23    30  ***********
  16    2024-04-02 19:24     ?  -
  17    2024-04-02 19:25    29  **********
  18    2024-04-02 19:26    30  ***********
  19    2024-04-02 19:27    30  ***********
  20    2024-04-02 19:28     ?  -
  21    2024-04-02 19:29    30  ***********
  22    2024-04-02 19:30     ?  -
  23    2024-04-02 19:31    29  **********
 ...    ..(  2 skipped).    ..  **********
  26    2024-04-02 19:34    29  **********
  27    2024-04-02 19:35     ?  -
  28    2024-04-02 19:36    29  **********
  29    2024-04-02 19:37    30  ***********
 ...    ..(  2 skipped).    ..  ***********
  32    2024-04-02 19:40    30  ***********
  33    2024-04-02 19:41     ?  -
  34    2024-04-02 19:42    30  ***********
  35    2024-04-02 19:43    32  *************
 ...    ..(  2 skipped).    ..  *************
  38    2024-04-02 19:46    32  *************

SMART WRITE LOG does not return COUNT and LBA_LOW register
SCT (Get) Error Recovery Control command failed

Device Statistics (SMART Log 0x04)
Page  Offset Size        Value Flags Description
ATA_SMART_READ_LOG failed: Undefined error: 0
Read Device Statistics pages 0x00-0x07 failed

Pending Defects log (GP Log 0x0c) not supported

ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented