Custom Query (1386 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (259 - 261 of 1386)

Ticket Resolution Summary Owner Reporter
#272 fixed Support for SanDisk iSSD P4 16GB (SSD_9.41) Christian Franke jacky672
Description

gnome-disk-utility seems to show more attribute_name

Device is: Not in smartctl database

ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0002   100   100   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       -       4148
 12 Power_Cycle_Count       0x0002   100   100   000    Old_age   Always       -       481
171 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       18
172 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       2230656
173 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       105
174 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       36
187 Reported_Uncorrect      0x0002   100   100   000    Old_age   Always       -       0
199 UDMA_CRC_Error_Count    0x0002   100   100   000    Old_age   Always       -       0
230 Head_Amplitude          0x0002   003   100   000    Old_age   Always       -       0
232 Available_Reservd_Space 0x0003   098   100   005    Pre-fail  Always       -       0
234 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       86
241 Total_LBAs_Written      0x0002   100   100   000    Old_age   Always       -       1112661066
242 Total_LBAs_Read         0x0002   100   100   000    Old_age   Always       -       685699629

#273 wontfix Support for Mylex AcceleRAID controllers somebody mrottotecnica
Description

I have a server running debian Linux 6.0.7 with a Mylex AcceleRAID 160 controller. The board is identified as follows:

RAID bus controller: Mylex Corporation AcceleRAID 352/170/160 support Device (rev 02)
Kernel driver in use: DAC960
PCI ID: 1069:0050
PIC subsystem id: 1069:0054

I've searched the web for information about how to get smart data out of the SCSI disks attached to this controller, but couldn't find any.

Is there any change smartmontools will eventually support this RAID controller ?

#274 invalid big temperature difference between smartd & smartctl somebody oximore
Description

Server: Debian squeeze smartmontools 5.39.1+svn3124-2


Hello,

The temperature I get from the log file is very different from the one I get with the smartctl command:

cat /var/log/syslog | grep Celsius

May  7 07:00:19 interne smartd[17990]: Device: /dev/sda [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 119 to 118
May  7 07:00:19 interne smartd[17990]: Device: /dev/sdc [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 118 to 117
May  7 07:30:18 interne smartd[17990]: Device: /dev/sdc [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 117 to 118
May  7 08:00:18 interne smartd[17990]: Device: /dev/sdb [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 32 to 33
May  7 08:00:19 interne smartd[17990]: Device: /dev/sdc [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 118 to 117
May  7 08:30:19 interne smartd[17990]: Device: /dev/sdb [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 33 to 32
May  7 08:30:20 interne smartd[17990]: Device: /dev/sdd [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 121 to 120
May  7 10:00:20 interne smartd[17990]: Device: /dev/sdc [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 117 to 118
May  7 11:00:19 interne smartd[17990]: Device: /dev/sdb [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 32 to 33
May  7 11:00:19 interne smartd[17990]: Device: /dev/sdd [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 120 to 121
...

And when I use smartctl:

smartctl -x /dev/sda

Current Temperature:                    32 Celsius

Index    Estimated Time   Temperature Celsius
  43    2013-05-07 12:59    32  *************
 ...    ..( 42 skipped).    ..  *************
  86    2013-05-07 13:42    32  *************
  87    2013-05-07 13:43    31  ************
 ...    ..( 15 skipped).    ..  ************
 103    2013-05-07 13:59    31  ************
 104    2013-05-07 14:00    32  *************
 ...    ..(122 skipped).    ..  *************
 227    2013-05-07 16:03    32  *************
 228    2013-05-07 16:04    33  **************
 ...    ..( 60 skipped).    ..  **************
 289    2013-05-07 17:05    33  **************
 290    2013-05-07 17:06    32  *************
 ...    ..(111 skipped).    ..  *************
 402    2013-05-07 18:58    32  *************
 403    2013-05-07 18:59    33  **************
 ...    ..( 58 skipped).    ..  **************
 462    2013-05-07 19:58    33  **************
 463    2013-05-07 19:59    32  *************
 ...    ..(  7 skipped).    ..  *************
 471    2013-05-07 20:07    32  *************
 472    2013-05-07 20:08    31  ************
 ...    ..( 25 skipped).    ..  ************
  20    2013-05-07 20:34    31  ************
  21    2013-05-07 20:35    32  *************
 ...    ..( 20 skipped).    ..  *************
  42    2013-05-07 20:56    32  *************

(same values for sdb, sdc & sdd)

Any idea where that comes from?

119° Celsius.. Imagine my face when I saw that :)

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.