Custom Query (1359 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (142 - 144 of 1359)

Ticket Resolution Summary Owner Reporter
#151 fixed Report working USB bridge manfred99 jlivdahl
Description

I would like to report that this Unknown USB bridge [0x0bc2:0x50a1]

Work with: -d sat,12

It is the Seagate FreeAgent GoFlex Desk USB 3.0 external HDD Tested with Windows 7 x64 with a Gigabyte GA-H55M-USB motherboard

#152 worksforme Sometimes smartd does not complaints about errors by email somebody art9
Description

Smartd does not complaint about errors by email sometimes by unknown reason.

For example this incident did not trigger notification:

Feb 24 20:32:25 mx14 smartd[19581]: Device: /dev/sg0 [megaraid_disk_51] [SAT], 4 Currently unreadable (pending) sectors (changed +1) Feb 24 20:32:25 mx14 smartd[19581]: Device: /dev/sg0 [megaraid_disk_51] [SAT], previous self-test completed with error (read test element) Feb 24 20:32:26 mx14 smartd[19581]: Device: /dev/sg0 [megaraid_disk_51] [SAT], Self-Test Log error count increased from 2 to 3

typical configuration:

/dev/sg0 -d sat+megaraid,50 -a -s L/../../7/00 -m postmaster /dev/sg0 -d sat+megaraid,51 -a -s L/../../7/00 -m postmaster /dev/sg0 -d sat+megaraid,52 -a -s L/../../7/00 -m postmaster

SVN rev 3267M

#153 fixed missing USB bridge for LaCie Drive Christian Franke thomasvs
Description

[root@davedina ~]# smartctl --all /dev/sde -d auto smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

/dev/sde: Unknown USB bridge [0x059f:0x1029 (0x100)] Smartctl: please specify device type with the -d option.

Use smartctl -h to get a usage summary

[root@davedina ~]# smartctl --all /dev/sde -d sat smartctl 5.40 2010-10-16 r3189 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

START OF INFORMATION SECTION

Model Family: Hitachi Deskstar 7K2000 Device Model: Hitachi HDS722020ALA330 Serial Number: JK1121YAG4220S Firmware Version: JKAOA10D User Capacity: 2,000,398,934,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 4 Local Time is: Fri Mar 4 16:45:52 2011 CET SMART support is: Available - device has SMART capability. SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status: (0x84) Offline data collection activity

was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled.

Self-test execution status: ( 0) The previous self-test routine completed

without error or no self-test has ever been run.

Total time to complete Offline data collection: (22036) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate.

Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode. Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 255) minutes. SCT capabilities: (0x003d) SCT Status supported.

SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported.

SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 134 134 054 Pre-fail Offline - 97 3 Spin_Up_Time 0x0007 114 114 024 Pre-fail Always - 632 (Average 635) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 56 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 1 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 112 112 020 Pre-fail Offline - 39 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 1595

10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 53

192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 56 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 56 194 Temperature_Celsius 0x0002 253 253 000 Old_age Always - 21 (Min/Max 17/58) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0

SMART Error Log Version: 0 No Errors Logged

SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1

SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS

1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing

Selective self-test flags (0x0):

After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

Works with SAT, so I think you can add it safely.

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.