Custom Query (69 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Status: closed (44 matches)

Ticket Summary Owner Type Priority Component Version
#1535 Code execution vulnerability if smartd uses 'mail' from GNU mailutils < 3.13 Christian Franke defect critical smartd
#336 Different check intervals for different devices Christian Franke enhancement major smartd 6.2
#1424 drivedb.h: Add VERSION information which works without $Id$ expansion Christian Franke enhancement major drivedb
#1454 Mail is only sent one recipient from the -m list, not counting plugins (smartd), the last one. Christian Franke defect major smartd 7.2
#1465 Use of wrong devicename in autodetection unter OpenBSD Christian Franke defect major all 7.2
#1466 Timeout too short for some devices under openBSD Christian Franke defect major all
#1546 Possible buffer overflow in smartctl.cpp Christian Franke defect major smartctl
#734 -d megaraid,N is not implemented, FreeBSD 10.3 w/ LSI MegaRAID 9271-8i SATA/SAS and mrsas (4) driver Alex Samorukov enhancement minor all 6.5
#1143 add N300 to drivedb: TOSHIBA HDWN160 Christian Franke enhancement minor drivedb 6.6
#1221 Add support for ASMedia ASM2362 USB to NVMe bridge Christian Franke enhancement minor all
#1236 add N300 to drivedb: TOSHIBA HDWG11A Christian Franke enhancement minor drivedb
#1251 TOSHIBA N300 4TB (HDWQ140) not in the smartctl/smartd database Christian Franke enhancement minor drivedb 7.0
#1277 Please add Toshiba HDWF180 to the database Christian Franke enhancement minor drivedb 6.6
#1303 Physical block size not displayed after a drive reset Christian Franke defect minor smartctl 7.1
#1323 Toshiba N300 drive enhancement minor drivedb
#1327 add to drivedb: Toshiba MG05 Series Christian Franke enhancement minor drivedb
#1364 M2CA032GXAIMS-003Z add to drivedb.h (Xmore) Christian Franke enhancement minor drivedb
#1380 Change in drivedb: Supermicro SATA DOM (SuperDOM) patch minor drivedb 7.1
#1381 --nocheck standby is ignored if device does not support power check which causes spin up Christian Franke enhancement minor smartctl 7.1
#1403 NVMe pass-through support for Samsung T7 SSD (0x04e8:0x4001) enhancement minor all 7.1
#1413 Some SCSI Drives spin up when using -n option. Christian Franke defect minor smartctl
#1415 Seagate Exos 7E8 missing from the database (ST8000NM000A, ...) Christian Franke patch minor drivedb
#1417 ADATA HV610 - USB bridge [0x125f:0xa21a (0x4504)] Christian Franke enhancement minor drivedb 7.1
#1426 update-smart-drivedb: Allow update from other URLs or local files Christian Franke enhancement minor all
#1427 Add support for SCT Error Recovery Timer features added in ACS-4 Christian Franke patch minor smartctl
#1428 Patch to support more JMicron JMS576 Christian Franke patch minor drivedb 7.2
#1430 Add drives not in database: TOSHIBA HDWD240 (P300 SMR) Christian Franke enhancement minor drivedb
#1436 Always add timestamp to json Christian Franke enhancement minor smartctl
#1439 smartmontools compile fails with "undefined reference to `__stack_chk_guard'" Christian Franke defect minor all 7.2
#1441 smartctl exit status 4 if SAT layer ignores CK_COND Christian Franke defect minor smartctl 7.2
#1452 Add to drivedb: Samsung SSD 883 DCT 3.84TB Christian Franke patch minor drivedb
#1457 Samsung SSD 860 QVO 1TB: Device is: Not in smartctl database Christian Franke enhancement minor drivedb
#1460 Add to drivedb: WDC WUH72181xALE6Lz Christian Franke patch minor drivedb
#1467 Autodetection under OpenBSD assumes full SCSI for sd-Devices defect minor all
#1472 HP Smart Array connected disk don't need -d cciss,N when in HBA mode Christian Franke defect minor all 7.2
#1475 Drive submission - SAMSUNG MZ7LF192HCGS-000L1 Christian Franke enhancement minor drivedb
#1484 Add SSSTC ER2-GD/CD xxxA to drive db Christian Franke enhancement minor drivedb
#1490 Unknown SSD Micron MTFDDAK256TDL-1AW1ZABFA Christian Franke enhancement minor drivedb 7.1
#1502 LaCie d2 PROFESSIONAL 0x059f:0x10b8 works with -d sat Christian Franke enhancement minor drivedb 7.2
#1503 SanDisk SSD PLUS 2000GB not in Database enhancement minor drivedb 7.2
#1509 MKNSSDS2500GB Christian Franke enhancement minor drivedb
#1510 TOSHIBA MN08ACA14T Christian Franke enhancement minor drivedb
#1511 TOSHIBA MN07ACA12T Christian Franke enhancement minor drivedb
#1542 update-smart-drivedb doesn't kill it's gpg-agent and throws errors on systems with root on NFS Christian Franke defect minor all 7.2

Status: new (25 matches)

Ticket Summary Owner Type Priority Component Version
#894 Support NVMe self tests enhancement major all 6.5
#1066 Please add a timeout parameter enhancement minor smartctl 7.2
#1348 Corsair Force LE patch minor drivedb
#1379 Add to drivedb: Novachips SCALAR-04T patch minor drivedb 7.1
#1389 Kingston RBU-SNSx180S3 series SSDs (e.g., RBUSNS4180S3256GJ) patch minor drivedb
#1393 add drive to database: SMART Modular SVM2S46128GNPI51UF enhancement minor drivedb 7.1
#1431 new hdd for database - IBM-Seagate-ST33000650NS enhancement minor drivedb 7.2
#1432 add to drivedb: IBM-WD-WD3000FYYZ-23UL enhancement minor drivedb 7.2
#1433 WDC-WD141KRYZ-01C66B0 - req. to add 14tb wd (hgst) helium gold drive to database enhancement minor drivedb
#1435 INTEL SSDSC2BF240A5L enhancement minor drivedb
#1442 Add to drivedb: KINGSTON SKC600MS256G enhancement minor drivedb 7.1
#1444 Add support for Apacer AS350 enhancement minor drivedb
#1449 Apacer-APS25AF7512G-5BTM1GWT patch minor drivedb
#1450 Not in smartctl database: WDC WDS400T1R0A_68A4W0 (WD Red SA500 SSD 4 Tb) enhancement minor drivedb 7.2
#1456 disk is missed in database (TOSHIBA-VT180) enhancement minor drivedb
#1458 WDC WUH721414ALE604 drive is not in the smartctl/smartd database enhancement minor drivedb 7.2
#1471 Add Raw Format for Seagate Error Rates (ST4000DM004-2CV104) enhancement minor drivedb
#1491 Support for Kingston SSDNow S200 (KINGSTON SS200S330G) enhancement minor drivedb
#1506 Toshiba Canvio Basics HDTB440EK3CA (TOSHIBA MQ04UBB400, 0x0480:0x0900) enhancement minor drivedb 6.6
#1532 Please add KingFast F Series to Database enhancement minor drivedb 7.2
#1536 Please add T-FORCE SSD to Database enhancement minor drivedb 7.2
#1543 Add to driveDB WDC WD102KFBX enhancement minor drivedb 7.2
#1547 Add WDC WUH721818ALN6L4 to db enhancement minor drivedb
#1548 Add HC560 to db enhancement minor drivedb
#1549 Add HC650 to db enhancement minor drivedb
Note: See TracQuery for help on using queries.