smartctl version 5.1-14 Copyright (C) 2002-3 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: MAXTOR 4K080H4 Serial Number: 674119123112 Firmware Version: A08.1500 Device is: In smartctl database [for details use: -P show] ATA Version is: 5 ATA Standard is: ATA/ATAPI-5 T13 1321D revision 1 Local Time is: Tue Aug 19 02:06:11 2003 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Off-line data collection status: (0x80) Offline data collection activity was never started. Auto Off-line Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete off-line data collection: ( 44) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Automatic timer ON/OFF support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. No General Purpose Logging support. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 50) minutes. SMART Attributes Data Structure revision number: 11 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x0029 100 253 020 Pre-fail Offline - 0 3 Spin_Up_Time 0x0027 075 074 020 Pre-fail Always - 3186 4 Start_Stop_Count 0x0032 100 100 008 Old_age Always - 68 5 Reallocated_Sector_Ct 0x0033 100 100 020 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0 9 Power_On_Hours 0x0012 074 074 001 Old_age Always - 17202 10 Spin_Retry_Count 0x0026 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0013 010 010 020 Pre-fail Always FAILING_NOW 9 12 Power_Cycle_Count 0x0032 100 100 008 Old_age Always - 68 13 Read_Soft_Error_Rate 0x000b 100 100 023 Pre-fail Always - 0 194 Temperature_Celsius 0x0022 092 087 042 Old_age Always - 22 195 Hardware_ECC_Recovered 0x001a 018 003 000 Old_age Always - 1082933060 196 Reallocated_Event_Count 0x0010 100 100 020 Old_age Offline - 0 197 Current_Pending_Sector 0x0032 100 100 020 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x001a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log, version number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended off-line Completed 00% 17157 - # 2 Extended off-line Completed 00% 16990 - # 3 Extended off-line Completed 00% 16823 - # 4 Extended off-line Completed 00% 16657 - # 5 Extended off-line Completed 00% 16598 - # 6 Extended off-line Completed 00% 16490 - # 7 Extended off-line Completed 00% 16323 - # 8 Extended off-line Completed 00% 16157 - # 9 Extended off-line Completed 00% 15991 - #10 Extended off-line Completed 00% 15696 - #11 Extended off-line Completed 00% 15614 - #12 Extended off-line Completed 00% 15241 - #13 Extended off-line Completed 00% 15026 - #14 Extended off-line Completed 00% 14785 - #15 Extended off-line Completed 00% 14334 - #16 Extended off-line Completed 00% 14129 - #17 Extended off-line Completed 00% 13750 - #18 Extended off-line Completed 00% 13665 - #19 Extended off-line Completed 00% 13262 - #20 Extended off-line Completed 00% 13108 - #21 Extended off-line Completed 00% 12125 -