smartctl version 5.31 Copyright (C) 2002-4 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: IC35L120AVV207-1 Serial Number: VNVD09G4H3HPMT Firmware Version: V24OA66A Device is: In smartctl database [for details use: -P show] ATA Version is: 6 ATA Standard is: ATA/ATAPI-6 T13 1410D revision 3a Local Time is: Tue Jun 15 23:38:56 2004 CDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: FAILED! Drive failure expected in less than 24 hours. SAVE ALL DATA. See vendor-specific Attribute list for failed Attributes. General SMART Values: Offline data collection status: (0x84) Offline data collection activity was suspended by an interrupting command from host. Auto Offline Data Collection: Enabled. Self-test execution status: ( 121) The previous self-test completed having the read element of the test failed. Total time to complete Offline data collection: (2855) seconds. Offline data collection capabilities: (0x1b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 48) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 089 089 060 Pre-fail Always - 1703986 2 Throughput_Performance 0x0005 015 015 050 Pre-fail Offline FAILING_NOW 5518 3 Spin_Up_Time 0x0007 100 100 024 Pre-fail Always - 278 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 9 5 Reallocated_Sector_Ct 0x0033 091 091 005 Pre-fail Always - 277 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 123 123 020 Pre-fail Offline - 37 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 2759 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9 192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 45 193 Load_Cycle_Count 0x0012 100 100 050 Old_age Always - 45 194 Temperature_Celsius 0x0002 166 166 000 Old_age Always - 33 (Lifetime Min/Max 23/44) 196 Reallocated_Event_Count 0x0032 092 092 000 Old_age Always - 319 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 49 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 20 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 161 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 161 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 46 c2 a7 02 e0 Error: UNC 70 sectors at LBA = 0x0002a7c2 = 174018 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 46 c2 a7 02 e0 00 23d+03:19:20.800 READ DMA EXT 25 00 48 c0 a7 02 e0 00 23d+03:19:16.000 READ DMA EXT 25 00 1c a4 a7 02 e0 00 23d+03:19:15.200 READ DMA EXT 25 00 1e a2 a7 02 e0 00 23d+03:19:10.400 READ DMA EXT 25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT Error 160 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 47 c1 a7 02 e0 Error: UNC 71 sectors at LBA = 0x0002a7c1 = 174017 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 48 c0 a7 02 e0 00 23d+03:19:16.000 READ DMA EXT 25 00 1c a4 a7 02 e0 00 23d+03:19:15.200 READ DMA EXT 25 00 1e a2 a7 02 e0 00 23d+03:19:10.400 READ DMA EXT 25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT 25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT Error 159 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 02 be a7 02 e0 Error: UNC 2 sectors at LBA = 0x0002a7be = 174014 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 1e a2 a7 02 e0 00 23d+03:19:10.400 READ DMA EXT 25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT 25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT 25 00 24 9c a7 02 e0 00 23d+03:18:52.400 READ DMA EXT 25 00 26 9a a7 02 e0 00 23d+03:18:40.200 READ DMA EXT Error 158 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 02 be a7 02 e0 Error: UNC 2 sectors at LBA = 0x0002a7be = 174014 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 20 a0 a7 02 e0 00 23d+03:19:02.200 READ DMA EXT 25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT 25 00 24 9c a7 02 e0 00 23d+03:18:52.400 READ DMA EXT 25 00 26 9a a7 02 e0 00 23d+03:18:40.200 READ DMA EXT 25 00 28 98 a7 02 e0 00 23d+03:18:32.100 READ DMA EXT Error 157 occurred at disk power-on lifetime: 2752 hours (114 days + 16 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 03 bd a7 02 e0 Error: UNC 3 sectors at LBA = 0x0002a7bd = 174013 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 00 22 9e a7 02 e0 00 23d+03:18:57.400 READ DMA EXT 25 00 24 9c a7 02 e0 00 23d+03:18:52.400 READ DMA EXT 25 00 26 9a a7 02 e0 00 23d+03:18:40.200 READ DMA EXT 25 00 28 98 a7 02 e0 00 23d+03:18:32.100 READ DMA EXT 25 00 2a 96 a7 02 e0 00 23d+03:18:26.400 READ DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed: read failure 90% 2692 173893 # 2 Short offline Completed: read failure 10% 2654 173911 # 3 Extended offline Completed: read failure 90% 2524 174132 # 4 Extended offline Completed without error 00% 2358 - # 5 Extended offline Completed without error 00% 2192 - # 6 Extended offline Completed without error 00% 2023 - # 7 Extended offline Completed without error 00% 1857 - # 8 Extended offline Completed without error 00% 1689 - # 9 Extended offline Completed without error 00% 1521 - #10 Extended offline Completed without error 00% 1355 - #11 Extended offline Completed without error 00% 1187 - #12 Extended offline Completed without error 00% 1020 - #13 Extended offline Completed without error 00% 854 - #14 Extended offline Completed without error 00% 685 - #15 Extended offline Completed without error 00% 517 - #16 Extended offline Completed without error 00% 349 - #17 Extended offline Completed without error 00% 181 - #18 Extended offline Completed without error 00% 13 - #19 Extended offline Completed without error 00% 4 - Device does not support Selective Self Tests/Logging