Line 
1smartctl 6.6 2017-11-05 r4594 [Darwin 17.3.0 x86_64] (local build)
2Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model:     PLEXTOR PX-512M7VC
6Serial Number:    P02736107105
7LU WWN Device Id: 5 002303 100f93b55
8Add. Product Id:  TC9020D0
9Firmware Version: 1.05
10User Capacity:    512,110,190,592 bytes [512 GB]
11Sector Size:      512 bytes logical/physical
12Rotation Rate:    Solid State Device
13Device is:        Not in smartctl database [for details use: -P showall]
14ATA Version is:   ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
15SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
16Local Time is:    Sun Jan 21 10:09:56 2018 CST
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is:   Unavailable
20APM feature is:   Unavailable
21Rd look-ahead is: Enabled
22Write cache is:   Enabled
23DSN feature is:   Unavailable
24ATA Security is:  Disabled, NOT FROZEN [SEC1]
25Wt Cache Reorder: Unknown
26
27=== START OF READ SMART DATA SECTION ===
28SMART overall-health self-assessment test result: PASSED
29
30General SMART Values:
31Offline data collection status:  (0x00) Offline data collection activity
32                                        was never started.
33                                        Auto Offline Data Collection: Disabled.
34Self-test execution status:      (   0) The previous self-test routine completed
35                                        without error or no self-test has ever
36                                        been run.
37Total time to complete Offline
38data collection:                (   10) seconds.
39Offline data collection
40capabilities:                    (0x15) SMART execute Offline immediate.
41                                        No Auto Offline data collection support.
42                                        Abort Offline collection upon new
43                                        command.
44                                        No Offline surface scan supported.
45                                        Self-test supported.
46                                        No Conveyance Self-test supported.
47                                        No Selective Self-test supported.
48SMART capabilities:            (0x0003) Saves SMART data before entering
49                                        power-saving mode.
50                                        Supports SMART auto save timer.
51Error logging capability:        (0x01) Error logging supported.
52                                        General Purpose Logging supported.
53Short self-test routine
54recommended polling time:        (   2) minutes.
55Extended self-test routine
56recommended polling time:        (  44) minutes.
57SCT capabilities:              (0x001d) SCT Status supported.
58                                        SCT Error Recovery Control supported.
59                                        SCT Feature Control supported.
60
61SMART Attributes Data Structure revision number: 1
62Vendor Specific SMART Attributes with Thresholds:
63ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
64  1 Raw_Read_Error_Rate     POSR-K   100   100   000    -    0
65  5 Reallocated_Sector_Ct   PO----   100   100   000    -    0
66  9 Power_On_Hours          -O----   100   100   000    -    1126
67 12 Power_Cycle_Count       PO----   100   100   000    -    828
68170 Unknown_Attribute       -O--CK   100   100   000    -    0
69171 Unknown_Attribute       PO----   100   100   000    -    0
70172 Unknown_Attribute       PO----   100   100   000    -    0
71173 Unknown_Attribute       PO----   100   100   000    -    2
72174 Unknown_Attribute       PO----   100   100   000    -    725
73175 Program_Fail_Count_Chip PO----   100   100   000    -    0
74176 Erase_Fail_Count_Chip   PO----   100   100   000    -    0
75177 Wear_Leveling_Count     PO----   100   100   000    -    3628
76178 Used_Rsvd_Blk_Cnt_Chip  PO----   100   100   000    -    0
77179 Used_Rsvd_Blk_Cnt_Tot   PO----   100   100   000    -    0
78180 Unused_Rsvd_Blk_Cnt_Tot PO--CK   100   100   000    -    2400
79181 Program_Fail_Cnt_Total  PO----   100   100   000    -    0
80182 Erase_Fail_Count_Total  PO----   100   100   000    -    0
81183 Runtime_Bad_Block       -O--CK   100   100   000    -    0
82184 End-to-End_Error        PO--CK   100   100   000    -    0
83187 Reported_Uncorrect      PO----   100   100   000    -    0
84188 Command_Timeout         -O--CK   100   100   000    -    0
85192 Power-Off_Retract_Count PO----   100   100   000    -    725
86195 Hardware_ECC_Recovered  PO----   100   100   000    -    0
87196 Reallocated_Event_Count PO----   100   100   000    -    0
88198 Offline_Uncorrectable   PO----   100   100   000    -    0
89199 UDMA_CRC_Error_Count    PO----   100   100   000    -    0
90232 Available_Reservd_Space PO----   100   100   010    -    0
91233 Media_Wearout_Indicator PO----   100   100   000    -    1360
92241 Total_LBAs_Written      PO----   100   100   000    -    1317
93242 Total_LBAs_Read         PO----   100   100   000    -    2180
94                            ||||||_ K auto-keep
95                            |||||__ C event count
96                            ||||___ R error rate
97                            |||____ S speed/performance
98                            ||_____ O updated online
99                            |______ P prefailure warning
100
101ATA_READ_LOG_EXT (addr=0x00:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
102Read GP Log Directory failed
103
104SMART Log Directory Version 1 [multi-sector log support]
105Address    Access  R/W   Size  Description
1060x00           SL  R/O      1  Log Directory
1070x01           SL  R/O      1  Summary SMART error log
1080x02           SL  R/O      2  Comprehensive SMART error log
1090x03           SL  R/O      1  Ext. Comprehensive SMART error log
1100x06           SL  R/O      1  SMART self-test log
1110x07           SL  R/O      1  Extended self-test log
1120x09           SL  R/W      1  Selective self-test log
1130x10           SL  R/O      1  NCQ Command Error log
1140x11           SL  R/O      1  SATA Phy Event Counters log
1150x30           SL  R/O      9  IDENTIFY DEVICE data log
1160x80-0x9f      SL  R/W     16  Host vendor specific log
1170xe0           SL  R/W      1  SCT Command/Status
1180xe1           SL  R/W      1  SCT Data Transfer
119
120SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
121
122SMART Error Log Version: 0
123No Errors Logged
124
125SMART Extended Self-test Log (GP Log 0x07) not supported
126
127SMART Self-test log structure revision number 1
128Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
129# 1  Short offline       Completed without error       00%      1126         -
130
131Selective Self-tests/Logging not supported
132
133SCT Status Version:                  3
134SCT Version (vendor specific):       1 (0x0001)
135SCT Support Level:                   1
136Device State:                        Active (0)
137Current Temperature:                    37 Celsius
138Power Cycle Min/Max Temperature:      ?/ ? Celsius
139Lifetime    Min/Max Temperature:      ?/ ? Celsius
140Under/Over Temperature Limit Count:   0/0
141
142SCT Data Table command not supported
143
144SMART WRITE LOG does not return COUNT and LBA_LOW register
145SCT (Get) Error Recovery Control command failed
146
147Device Statistics (GP/SMART Log 0x04) not supported
148
149Pending Defects log (GP Log 0x0c) not supported
150
151ATA_READ_LOG_EXT (addr=0x11:0x00, page=0, n=1) failed: 48-bit ATA commands not implemented
152Read SATA Phy Event Counters failed
153