Ticket #976: smartctl.txt

File smartctl.txt, 7.0 KB (added by Usernameqwertyu, 6 years ago)
Line 
1
2=== START OF INFORMATION SECTION ===
3Device Model:     SSD Smartbuy 240GB
4Serial Number:    A444078C083100056845
5LU WWN Device Id: 0 000000 000000000
6Firmware Version: SBFM91.1
7User Capacity:    240 057 409 536 bytes [240 GB]
8Sector Size:      512 bytes logical/physical
9Rotation Rate:    Solid State Device
10Form Factor:      2.5 inches
11Device is:        Not in smartctl database [for details use: -P showall]
12ATA Version is:   ACS-4 (minor revision not indicated)
13SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
14Local Time is:    Fri Feb  9 20:23:38 2018 EDT
15SMART support is: Available - device has SMART capability.
16SMART support is: Enabled
17AAM feature is:   Unavailable
18APM feature is:   Unavailable
19Rd look-ahead is: Enabled
20Write cache is:   Enabled
21DSN feature is:   Unavailable
22ATA Security is:  Disabled, frozen [SEC2]
23Wt Cache Reorder: Unavailable
24
25=== START OF READ SMART DATA SECTION ===
26SMART overall-health self-assessment test result: PASSED
27
28General SMART Values:
29Offline data collection status:  (0x00) Offline data collection activity
30                                        was never started.
31                                        Auto Offline Data Collection: Disabled.
32Self-test execution status:      (   0) The previous self-test routine completed
33                                        without error or no self-test has ever
34                                        been run.
35Total time to complete Offline
36data collection:                (65535) seconds.
37Offline data collection
38capabilities:                    (0x79) SMART execute Offline immediate.
39                                        No Auto Offline data collection support.
40                                        Suspend Offline collection upon new
41                                        command.
42                                        Offline surface scan supported.
43                                        Self-test supported.
44                                        Conveyance Self-test supported.
45                                        Selective Self-test supported.
46SMART capabilities:            (0x0003) Saves SMART data before entering
47                                        power-saving mode.
48                                        Supports SMART auto save timer.
49Error logging capability:        (0x01) Error logging supported.
50                                        General Purpose Logging supported.
51Short self-test routine
52recommended polling time:        (   2) minutes.
53Extended self-test routine
54recommended polling time:        (  30) minutes.
55Conveyance self-test routine
56recommended polling time:        (   6) minutes.
57
58SMART Attributes Data Structure revision number: 16
59Vendor Specific SMART Attributes with Thresholds:
60ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
61  1 Raw_Read_Error_Rate     PO-R--   100   100   050    -    0
62  9 Power_On_Hours          -O--C-   100   100   000    -    106
63 12 Power_Cycle_Count       -O--C-   100   100   000    -    28
64168 Unknown_Attribute       -O--C-   100   100   000    -    0
65170 Unknown_Attribute       PO----   081   081   000    -    406
66173 Unknown_Attribute       -O--C-   100   100   000    -    3
67192 Power-Off_Retract_Count -O--C-   100   100   000    -    19
68194 Temperature_Celsius     PO---K   067   067   000    -    33 (Min/Max 33/33)
69218 Unknown_Attribute       PO-R--   100   100   050    -    0
70231 Temperature_Celsius     PO--C-   100   100   000    -    100
71241 Total_LBAs_Written      -O--C-   100   100   000    -    120
72                            ||||||_ K auto-keep
73                            |||||__ C event count
74                            ||||___ R error rate
75                            |||____ S speed/performance
76                            ||_____ O updated online
77                            |______ P prefailure warning
78
79General Purpose Log Directory Version 1
80SMART           Log Directory Version 1 [multi-sector log support]
81Address    Access  R/W   Size  Description
820x00       GPL,SL  R/O      1  Log Directory
830x01           SL  R/O      1  Summary SMART error log
840x02           SL  R/O     51  Comprehensive SMART error log
850x03       GPL     R/O     64  Ext. Comprehensive SMART error log
860x04       GPL,SL  R/O      8  Device Statistics log
870x06           SL  R/O      1  SMART self-test log
880x07       GPL     R/O      1  Extended self-test log
890x09           SL  R/W      1  Selective self-test log
900x10       GPL     R/O      1  NCQ Command Error log
910x11       GPL     R/O      1  SATA Phy Event Counters log
920x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
930x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
94
95SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
96No Errors Logged
97
98SMART Extended Self-test Log Version: 1 (1 sectors)
99No self-tests have been logged.  [To run self-tests, use: smartctl -t]
100
101SMART Selective self-test log data structure revision number 0
102Note: revision number not 1 implies that no selective self-test has ever been run
103 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
104    1        0        0  Not_testing
105    2        0        0  Not_testing
106    3        0        0  Not_testing
107    4        0        0  Not_testing
108    5        0        0  Not_testing
109Selective self-test flags (0x0):
110  After scanning selected spans, do NOT read-scan remainder of disk.
111If Selective self-test is pending on power-up, resume after 0 minute delay.
112
113SCT Commands not supported
114
115Device Statistics (GP Log 0x04)
116Page  Offset Size        Value Flags Description
1170x01  =====  =               =  ===  == General Statistics (rev 1) ==
1180x01  0x008  4              28  ---  Lifetime Power-On Resets
1190x01  0x010  4             106  ---  Power-on Hours
1200x01  0x018  6       253105098  ---  Logical Sectors Written
1210x01  0x028  6       141576038  ---  Logical Sectors Read
1220x04  =====  =               =  ===  == General Errors Statistics (rev 1) ==
1230x04  0x008  4               0  ---  Number of Reported Uncorrectable Errors
1240x05  =====  =               =  ===  == Temperature Statistics (rev 1) ==
1250x05  0x008  1              33  ---  Current Temperature
1260x05  0x020  1              33  ---  Highest Temperature
1270x05  0x028  1              33  ---  Lowest Temperature
1280x06  =====  =               =  ===  == Transport Statistics (rev 1) ==
1290x06  0x018  4               0  ---  Number of Interface CRC Errors
1300x07  =====  =               =  ===  == Solid State Device Statistics (rev 1) ==
1310x07  0x008  1               0  ---  Percentage Used Endurance Indicator
132                                |||_ C monitored condition met
133                                ||__ D supports DSN
134                                |___ N normalized value
135
136Pending Defects log (GP Log 0x0c) not supported
137
138SATA Phy Event Counters (GP Log 0x11)
139ID      Size     Value  Description
1400x0001  2            0  Command failed due to ICRC error
1410x0003  2            0  R_ERR response for device-to-host data FIS
1420x0004  2            0  R_ERR response for host-to-device data FIS
1430x0006  2            0  R_ERR response for device-to-host non-data FIS
1440x0007  2            0  R_ERR response for host-to-device non-data FIS
1450x0008  2            0  Device-to-host non-data FIS retries
1460x0009  4           19  Transition from drive PhyRdy to drive PhyNRdy
1470x000a  4           20  Device-to-host register FISes sent due to a COMRESET
1480x000f  2            0  R_ERR response for host-to-device data FIS, CRC
1490x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
1500x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
1510x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC
152