1smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.4.88] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model:     ADATA SU800
6Serial Number:    2H4320069880
7LU WWN Device Id: 5 707c18 1005bd539
8Firmware Version: Q0913A
9User Capacity:    128,035,676,160 bytes [128 GB]
10Sector Size:      512 bytes logical/physical
11Rotation Rate:    Solid State Device
12Form Factor:      2.5 inches
13Device is:        Not in smartctl database [for details use: -P showall]
14ATA Version is:   ACS-3 T13/2161-D revision 5
15SATA Version is:  SATA >3.2 (0x1ff), 6.0 Gb/s (current: 6.0 Gb/s)
16Local Time is:    Sat Dec  9 05:17:44 2017 EET
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19
20=== START OF READ SMART DATA SECTION ===
21SMART overall-health self-assessment test result: PASSED
22
23General SMART Values:
24Offline data collection status:  (0x80) Offline data collection activity
25                                        was never started.
26                                        Auto Offline Data Collection: Enabled.
27Self-test execution status:      (   0) The previous self-test routine completed
28                                        without error or no self-test has ever
29                                        been run.
30Total time to complete Offline
31data collection:                (    0) seconds.
32Offline data collection
33capabilities:                    (0x7b) SMART execute Offline immediate.
34                                        Auto Offline data collection on/off support.
35                                        Suspend Offline collection upon new
36                                        command.
37                                        Offline surface scan supported.
38                                        Self-test supported.
39                                        Conveyance Self-test supported.
40                                        Selective Self-test supported.
41SMART capabilities:            (0x0002) Does not save SMART data before
42                                        entering power-saving mode.
43                                        Supports SMART auto save timer.
44Error logging capability:        (0x01) Error logging supported.
45                                        General Purpose Logging supported.
46Short self-test routine
47recommended polling time:        (   2) minutes.
48Extended self-test routine
49recommended polling time:        (  30) minutes.
50Conveyance self-test routine
51recommended polling time:        (   2) minutes.
52SCT capabilities:              (0x0035) SCT Status supported.
53                                        SCT Feature Control supported.
54                                        SCT Data Table supported.
55
56SMART Attributes Data Structure revision number: 16
57Vendor Specific SMART Attributes with Thresholds:
58ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
59  1 Raw_Read_Error_Rate     0x0000   100   100   000    Old_age   Offline      -       0
60  5 Reallocated_Sector_Ct   0x0000   100   100   000    Old_age   Offline      -       1
61  9 Power_On_Hours          0x0000   100   100   000    Old_age   Offline      -       9
62 12 Power_Cycle_Count       0x0000   100   100   000    Old_age   Offline      -       10
63148 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       64
64149 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       8
65150 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       2
66151 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       4
67159 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       0
68160 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       0
69161 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       25
70163 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       31
71164 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       3409
72165 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       11
73166 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       5
74167 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       7
75169 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       100
76177 Wear_Leveling_Count     0x0000   100   100   050    Old_age   Offline      -       0
77181 Program_Fail_Cnt_Total  0x0000   100   100   000    Old_age   Offline      -       0
78182 Erase_Fail_Count_Total  0x0000   100   100   000    Old_age   Offline      -       0
79192 Power-Off_Retract_Count 0x0000   100   100   000    Old_age   Offline      -       2
80194 Temperature_Celsius     0x0000   100   100   000    Old_age   Offline      -       32
81196 Reallocated_Event_Count 0x0000   100   100   016    Old_age   Offline      -       65
82199 UDMA_CRC_Error_Count    0x0000   100   100   050    Old_age   Offline      -       0
83232 Available_Reservd_Space 0x0000   100   100   000    Old_age   Offline      -       100
84241 Total_LBAs_Written      0x0000   100   100   000    Old_age   Offline      -       11293
85242 Total_LBAs_Read         0x0000   100   100   000    Old_age   Offline      -       8447
86245 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       30681
87250 Read_Error_Retry_Rate   0x0000   100   100   000    Old_age   Offline      -       0
88251 Unknown_Attribute       0x0000   100   100   000    Old_age   Offline      -       0
89
90SMART Error Log Version: 1
91No Errors Logged
92
93SMART Self-test log structure revision number 1
94No self-tests have been logged.  [To run self-tests, use: smartctl -t]
95
96SMART Selective self-test log data structure revision number 1
97 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
98    1        0        0  Not_testing
99    2        0        0  Not_testing
100    3        0        0  Not_testing
101    4        0        0  Not_testing
102    5        0        0  Completed [00% left] (0-65535)
103Selective self-test flags (0x0):
104  After scanning selected spans, do NOT read-scan remainder of disk.
105If Selective self-test is pending on power-up, resume after 0 minute delay.