| 1 | smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.9.0-3-amd64] (local build)
|
|---|
| 2 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
|
|---|
| 3 |
|
|---|
| 4 | === START OF INFORMATION SECTION ===
|
|---|
| 5 | Vendor: HGST
|
|---|
| 6 | Product: HUSMM1640ASS200
|
|---|
| 7 | Revision: A360
|
|---|
| 8 | Compliance: SPC-4
|
|---|
| 9 | User Capacity: 400,088,457,216 bytes [400 GB]
|
|---|
| 10 | Logical block size: 512 bytes
|
|---|
| 11 | Physical block size: 4096 bytes
|
|---|
| 12 | LU is resource provisioned, LBPRZ=1
|
|---|
| 13 | Rotation Rate: Solid State Device
|
|---|
| 14 | Form Factor: 2.5 inches
|
|---|
| 15 | Logical Unit id: 0x5000cca04ec26e38
|
|---|
| 16 | Serial number: 0QYEXUPA
|
|---|
| 17 | Device type: disk
|
|---|
| 18 | Transport protocol: SAS (SPL-3)
|
|---|
| 19 | Local Time is: Fri Nov 24 15:34:04 2017 CET
|
|---|
| 20 | SMART support is: Available - device has SMART capability.
|
|---|
| 21 | SMART support is: Enabled
|
|---|
| 22 | Temperature Warning: Enabled
|
|---|
| 23 | Read Cache is: Enabled
|
|---|
| 24 | Writeback Cache is: Enabled
|
|---|
| 25 |
|
|---|
| 26 | === START OF READ SMART DATA SECTION ===
|
|---|
| 27 | SMART Health Status: OK
|
|---|
| 28 |
|
|---|
| 29 | Percentage used endurance indicator: 0%
|
|---|
| 30 | Current Drive Temperature: 27 C
|
|---|
| 31 | Drive Trip Temperature: 70 C
|
|---|
| 32 |
|
|---|
| 33 | Manufactured in week 30 of year 2017
|
|---|
| 34 | Specified cycle count over device lifetime: 0
|
|---|
| 35 | Accumulated start-stop cycles: 0
|
|---|
| 36 | Specified load-unload count over device lifetime: 0
|
|---|
| 37 | Accumulated load-unload cycles: 0
|
|---|
| 38 | defect list format 6 unknown
|
|---|
| 39 | Elements in grown defect list: 0
|
|---|
| 40 |
|
|---|
| 41 | Vendor (Seagate) cache information
|
|---|
| 42 | Blocks sent to initiator = 732546333671424
|
|---|
| 43 |
|
|---|
| 44 | Error counter log:
|
|---|
| 45 | Errors Corrected by Total Correction Gigabytes Total
|
|---|
| 46 | ECC rereads/ errors algorithm processed uncorrected
|
|---|
| 47 | fast | delayed rewrites corrected invocations [10^9 bytes] errors
|
|---|
| 48 | read: 0 0 0 0 0 43.168 0
|
|---|
| 49 | write: 0 0 0 0 0 2002.007 0
|
|---|
| 50 |
|
|---|
| 51 | Non-medium error count: 0
|
|---|
| 52 |
|
|---|
| 53 | SMART Self-test log
|
|---|
| 54 | Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ]
|
|---|
| 55 | Description number (hours)
|
|---|
| 56 | # 1 Background short Completed - 2104 - [- - -]
|
|---|
| 57 |
|
|---|
| 58 | Long (extended) Self Test duration: 2774 seconds [46.2 minutes]
|
|---|
| 59 |
|
|---|
| 60 | Background scan results log
|
|---|
| 61 | Status: no scans active
|
|---|
| 62 | Accumulated power on time, hours:minutes 2104:45 [126285 minutes]
|
|---|
| 63 | Number of background scans performed: 0, scan progress: 0.00%
|
|---|
| 64 | Number of background medium scans performed: 0
|
|---|
| 65 |
|
|---|
| 66 | Protocol Specific port log page for SAS SSP
|
|---|
| 67 | relative target port id = 1
|
|---|
| 68 | generation code = 6
|
|---|
| 69 | number of phys = 1
|
|---|
| 70 | phy identifier = 0
|
|---|
| 71 | attached device type: expander device
|
|---|
| 72 | attached reason: SMP phy control function
|
|---|
| 73 | reason: unknown
|
|---|
| 74 | negotiated logical link rate: phy enabled; 12 Gbps
|
|---|
| 75 | attached initiator port: ssp=0 stp=0 smp=0
|
|---|
| 76 | attached target port: ssp=0 stp=0 smp=1
|
|---|
| 77 | SAS address = 0x5000cca04ec26e39
|
|---|
| 78 | attached SAS address = 0x5003048009101a7f
|
|---|
| 79 | attached phy identifier = 0
|
|---|
| 80 | Invalid DWORD count = 4
|
|---|
| 81 | Running disparity error count = 4
|
|---|
| 82 | Loss of DWORD synchronization = 3
|
|---|
| 83 | Phy reset problem = 0
|
|---|
| 84 | Phy event descriptors:
|
|---|
| 85 | Invalid word count: 4
|
|---|
| 86 | Running disparity error count: 4
|
|---|
| 87 | Loss of dword synchronization count: 3
|
|---|
| 88 | Phy reset problem count: 0
|
|---|
| 89 | relative target port id = 2
|
|---|
| 90 | generation code = 6
|
|---|
| 91 | number of phys = 1
|
|---|
| 92 | phy identifier = 1
|
|---|
| 93 | attached device type: expander device
|
|---|
| 94 | attached reason: SMP phy control function
|
|---|
| 95 | reason: unknown
|
|---|
| 96 | negotiated logical link rate: phy enabled; 12 Gbps
|
|---|
| 97 | attached initiator port: ssp=0 stp=0 smp=0
|
|---|
| 98 | attached target port: ssp=0 stp=0 smp=1
|
|---|
| 99 | SAS address = 0x5000cca04ec26e3a
|
|---|
| 100 | attached SAS address = 0x5003048009101aff
|
|---|
| 101 | attached phy identifier = 0
|
|---|
| 102 | Invalid DWORD count = 4
|
|---|
| 103 | Running disparity error count = 4
|
|---|
| 104 | Loss of DWORD synchronization = 3
|
|---|
| 105 | Phy reset problem = 0
|
|---|
| 106 | Phy event descriptors:
|
|---|
| 107 | Invalid word count: 4
|
|---|
| 108 | Running disparity error count: 4
|
|---|
| 109 | Loss of dword synchronization count: 3
|
|---|
| 110 | Phy reset problem count: 0
|
|---|
| 111 |
|
|---|