Ticket #907: wdc4002fyyz.txt

File wdc4002fyyz.txt, 5.2 KB (added by Dorian Bivolaru, 7 years ago)
Line 
1smartctl 6.5 2016-05-07 r4318 [x86_64-w64-mingw32-win7-sp1] (sf-6.5-1)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: WDC WD4002FYYZ-01B7CB0
6Firmware Version: 01.01M02
7User Capacity: 4,000,787,030,016 bytes [4.00 TB]
8Sector Size: 512 bytes logical/physical
9Rotation Rate: 7200 rpm
10Form Factor: 3.5 inches
11Device is: Not in smartctl database [for details use: -P showall]
12ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4
13SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
14Local Time is: Tue Oct 03 01:52:10 2017 WEDT
15SMART support is: Available - device has SMART capability.
16SMART support is: Enabled
17
18=== START OF READ SMART DATA SECTION ===
19SMART overall-health self-assessment test result: PASSED
20
21General SMART Values:
22Offline data collection status: (0x82) Offline data collection activity
23 was completed without error.
24 Auto Offline Data Collection: Enabled.
25Self-test execution status: ( 0) The previous self-test routine completed
26
27 without error or no self-test has ever
28 been run.
29Total time to complete Offline
30data collection: ( 113) seconds.
31Offline data collection
32capabilities: (0x5b) SMART execute Offline immediate.
33 Auto Offline data collection on/off supp
34ort.
35 Suspend Offline collection upon new
36 command.
37 Offline surface scan supported.
38 Self-test supported.
39 No Conveyance Self-test supported.
40 Selective Self-test supported.
41SMART capabilities: (0x0003) Saves SMART data before entering
42 power-saving mode.
43 Supports SMART auto save timer.
44Error logging capability: (0x01) Error logging supported.
45 General Purpose Logging supported.
46Short self-test routine
47recommended polling time: ( 2) minutes.
48Extended self-test routine
49recommended polling time: ( 571) minutes.
50SCT capabilities: (0x003d) SCT Status supported.
51 SCT Error Recovery Control supported.
52 SCT Feature Control supported.
53 SCT Data Table supported.
54
55SMART Attributes Data Structure revision number: 16
56Vendor Specific SMART Attributes with Thresholds:
57ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_
58FAILED RAW_VALUE
59 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always -
60 0
61 2 Throughput_Performance 0x0005 137 137 054 Pre-fail Offline -
62 104
63 3 Spin_Up_Time 0x0007 137 137 024 Pre-fail Always -
64 480 (Average 480)
65 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always -
66 69
67 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always -
68 0
69 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always -
70 0
71 8 Seek_Time_Performance 0x0005 128 128 020 Pre-fail Offline -
72 18
73 9 Power_On_Hours 0x0012 100 100 000 Old_age Always -
74 208
75 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always -
76 0
77 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always -
78 41
79192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always -
80 129
81193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always -
82 129
83194 Temperature_Celsius 0x0002 162 162 000 Old_age Always -
84 37 (Min/Max 23/40)
85196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always -
86 0
87197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always -
88 0
89198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline -
90 0
91199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always -
92 0
93
94SMART Error Log Version: 1
95No Errors Logged
96
97SMART Self-test log structure revision number 1
98Num Test_Description Status Remaining LifeTime(hours) LBA
99_of_first_error
100# 1 Short offline Completed without error 00% 177 -
101
102SMART Selective self-test log data structure revision number 1
103 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
104 1 0 0 Not_testing
105 2 0 0 Not_testing
106 3 0 0 Not_testing
107 4 0 0 Not_testing
108 5 0 0 Not_testing
109Selective self-test flags (0x0):
110 After scanning selected spans, do NOT read-scan remainder of disk.
111If Selective self-test is pending on power-up, resume after 0 minute delay.
112