Ticket #874: smartctl-HFS500G32TND-N1A2A.txt

File smartctl-HFS500G32TND-N1A2A.txt, 5.3 KB (added by Brij Kishore Rai, 7 years ago)

SC308 log

Line 
1smartctl 6.6 2017-08-08 r4433 [x86_64-w64-mingw32-win7-sp1] (daily-20170808)
2Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Model Family: SKhynix SATA Client SC308 Series
6Device Model: HFS500G32TND-N1A2A
7Serial Number: FI63Q046810104704
8Firmware Version: 30000P10
9User Capacity: 500,107,862,016 bytes [500 GB]
10Sector Sizes: 512 bytes logical, 4096 bytes physical
11Rotation Rate: Solid State Device
12Form Factor: 2.5 inches
13Device is: In smartctl database [for details use: -P show]
14ATA Version is: ACS-2 (minor revision not indicated)
15SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
16Local Time is: Mon Sep 18 10:00:38 2017 PDT
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19
20=== START OF READ SMART DATA SECTION ===
21SMART overall-health self-assessment test result: PASSED
22
23General SMART Values:
24Offline data collection status: (0x02) Offline data collection activity
25 was completed without error.
26 Auto Offline Data Collection: Disabled.
27Self-test execution status: ( 36) The self-test routine was interrupted
28 by the host with a hard or soft reset.
29Total time to complete Offline
30data collection: ( 105) seconds.
31Offline data collection
32capabilities: (0x19) SMART execute Offline immediate.
33 No Auto Offline data collection support.
34 Suspend Offline collection upon new
35 command.
36 Offline surface scan supported.
37 Self-test supported.
38 No Conveyance Self-test supported.
39 No Selective Self-test supported.
40SMART capabilities: (0x0002) Does not save SMART data before
41 entering power-saving mode.
42 Supports SMART auto save timer.
43Error logging capability: (0x01) Error logging supported.
44 General Purpose Logging supported.
45Short self-test routine
46recommended polling time: ( 2) minutes.
47Extended self-test routine
48recommended polling time: ( 60) minutes.
49
50SMART Attributes Data Structure revision number: 0
51Vendor Specific SMART Attributes with Thresholds:
52ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
53 1 Raw_Read_Error_Rate 0x000f 166 166 006 Pre-fail Always - 0
54 5 Retired_Block_Count 0x0032 253 100 036 Old_age Always - 0
55 9 Power_On_Hours 0x0032 253 100 000 Old_age Always - 0
56 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 5
57100 Total_Erase_Count 0x0032 100 100 000 Old_age Always - 1054151
58168 Min_Erase_Count 0x0032 253 100 000 Old_age Always - 0
59169 Max_Erase_Count 0x0032 099 099 000 Old_age Always - 20
60171 Program_Fail_Count 0x0032 253 253 000 Old_age Always - 0
61172 Erase_Fail_Count 0x0032 253 253 000 Old_age Always - 0
62174 Unexpect_Power_Loss_Cnt 0x0030 253 100 000 Old_age Offline - 0
63175 Program_Fail_Count_Chip 0x0032 253 253 000 Old_age Always - 0
64176 Unused_Rsvd_Blk_Cnt_Tot 0x0032 253 253 000 Old_age Always - 0
65177 Wear_Leveling_Count 0x0032 253 100 000 Old_age Always - 0
66178 Used_Rsvd_Blk_Cnt_Chip 0x0032 100 100 000 Old_age Always - 33
67179 Used_Rsvd_Blk_Cnt_Tot 0x0032 100 100 000 Old_age Always - 502
68180 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 13386
69184 End-to-End_Error 0x0032 253 253 000 Old_age Always - 0
70187 Reported_Uncorrect 0x0032 253 253 000 Old_age Always - 0
71188 Command_Timeout 0x0032 253 253 000 Old_age Always - 0
72194 Temperature_Celsius 0x0002 026 000 000 Old_age Always - 26 (Min/Max 22/29)
73195 Hardware_ECC_Recovered 0x0032 253 253 000 Old_age Always - 0
74196 Reallocated_Event_Count 0x0032 253 100 036 Old_age Always - 0
75198 Offline_Uncorrectable 0x0032 253 253 000 Old_age Always - 0
76199 UDMA_CRC_Error_Count 0x0032 253 253 000 Old_age Always - 0
77204 Soft_ECC_Correction 0x000e 100 100 000 Old_age Always - 0
78212 Phy_Error_Count 0x0032 253 253 000 Old_age Always - 0
79234 Unknown_Attribute 0x0032 253 100 000 Old_age Always - 0
80241 Total_LBAs_Written 0x0032 253 100 000 Old_age Always - 0
81242 Total_LBAs_Read 0x0032 253 100 000 Old_age Always - 0
82250 NAND_Reads_Retry 0x0032 100 100 000 Old_age Always - 12
83
84SMART Error Log Version: 0
85No Errors Logged
86
87SMART Self-test log structure revision number 1
88Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
89# 1 Short offline Completed without error 00% 0 -
90# 2 Short offline Completed without error 90% 7 -
91
92Selective Self-tests/Logging not supported
93