1 | Microsoft Windows [Version 6.1.7601] |
---|
2 | Copyright (c) 2009 Microsoft Corporation. All rights reserved. |
---|
3 | |
---|
4 | C:\smartmon>smartctl.exe --scan |
---|
5 | /dev/sdb -d scsi # /dev/sdb, SCSI device |
---|
6 | /dev/sdc -d scsi # /dev/sdc, SCSI device |
---|
7 | /dev/sdd -d ata # /dev/sdd, ATA device |
---|
8 | |
---|
9 | C:\smartmon>smartctl.exe -A /dev/sdb |
---|
10 | smartctl 6.6 (build date Jun 28 2017) [x86_64-pc-msys-2008r2-sp1] (local build) |
---|
11 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org |
---|
12 | |
---|
13 | === START OF READ SMART DATA SECTION === |
---|
14 | Current Drive Temperature: 38 C |
---|
15 | Drive Trip Temperature: 63 C |
---|
16 | |
---|
17 | Manufactured in week 39 of year 2014 |
---|
18 | Specified cycle count over device lifetime: 0 |
---|
19 | Accumulated start-stop cycles: 6398 |
---|
20 | ID# ATTRIBUTE_NAME VALUE THRESH WORST |
---|
21 | 1 Raw_Read_Err_Rate 2 200 6 |
---|
22 | 2 Flash_ROM_Check 0 100 0 |
---|
23 | 5 Reallocated_Blk_Ct 0 49912 0 |
---|
24 | 9 Power_ON_Hours 3396 0 3396 |
---|
25 | 12 Power_Cycle_Ct 6398 0 6398 |
---|
26 | 13 ECC_Rate 32 65535 32 |
---|
27 | 29 Pwr_Fail_Backup_Circuit 100 0 100 |
---|
28 | 32 Avg_Write_Amplification 0 0 539 |
---|
29 | 177 Drive_Life_Remain% 99 2 99 |
---|
30 | 178 Drive_Life_Remain_x100 9853 200 9853 |
---|
31 | 180 Unused_Reserved_Blk_Ct 47643 0 47643 |
---|
32 | 181 Program_Fail_Ct 0 0 0 |
---|
33 | 182 Erase_Fail_Ct 0 0 0 |
---|
34 | 190 Drive_Temp_Warning 45 65 65 |
---|
35 | 194 Drive_Temperature 45 70 65 |
---|
36 | 195 UECC_Ct 0 0 0 |
---|
37 | 198 Offline_Scan_UEC 0 0 0 |
---|
38 | 233 Number_Of_LBA_Written 335479 0 335479 |
---|
39 | 245 DriveLife_Used% 1 98 1 |
---|
40 | 246 DriveLife_Used%x100 147 9800 147 |
---|
41 | defect list format 6 unknown |
---|
42 | Elements in grown defect list: 0 |
---|
43 | |
---|
44 | |
---|
45 | C:\smartmon>smartctl.exe -x /dev/sdb |
---|
46 | smartctl 6.6 (build date Jun 28 2017) [x86_64-pc-msys-2008r2-sp1] (local build) |
---|
47 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org |
---|
48 | |
---|
49 | === START OF INFORMATION SECTION === |
---|
50 | Vendor: SanDisk |
---|
51 | Product: DOPE1920S5xnNMRI |
---|
52 | Revision: P018 |
---|
53 | Compliance: SPC-4 |
---|
54 | User Capacity: 1,950,389,400,960 bytes [1.95 TB] |
---|
55 | Logical block size: 520 bytes |
---|
56 | Physical block size: 4160 bytes |
---|
57 | LU is resource provisioned, LBPRZ=1 |
---|
58 | Rotation Rate: Solid State Device |
---|
59 | Form Factor: 2.5 inches |
---|
60 | Logical Unit id: 0x5001173100309154 |
---|
61 | Serial number: FG00F2HW |
---|
62 | Device type: disk |
---|
63 | Transport protocol: SAS (SPL-3) |
---|
64 | Local Time is: Tue Oct 17 14:10:53 2017 IST |
---|
65 | SMART support is: Available - device has SMART capability. |
---|
66 | SMART support is: Enabled |
---|
67 | Temperature Warning: Enabled |
---|
68 | Read Cache is: Enabled |
---|
69 | Writeback Cache is: Disabled |
---|
70 | |
---|
71 | === START OF READ SMART DATA SECTION === |
---|
72 | SMART Health Status: OK |
---|
73 | |
---|
74 | Percentage used endurance indicator: 1% |
---|
75 | Current Drive Temperature: 38 C |
---|
76 | Drive Trip Temperature: 63 C |
---|
77 | |
---|
78 | Manufactured in week 39 of year 2014 |
---|
79 | Specified cycle count over device lifetime: 0 |
---|
80 | Accumulated start-stop cycles: 6398 |
---|
81 | ID# ATTRIBUTE_NAME VALUE THRESH WORST |
---|
82 | 1 Raw_Read_Err_Rate 2 200 6 |
---|
83 | 2 Flash_ROM_Check 0 100 0 |
---|
84 | 5 Reallocated_Blk_Ct 0 49912 0 |
---|
85 | 9 Power_ON_Hours 3396 0 3396 |
---|
86 | 12 Power_Cycle_Ct 6398 0 6398 |
---|
87 | 13 ECC_Rate 32 65535 32 |
---|
88 | 29 Pwr_Fail_Backup_Circuit 100 0 100 |
---|
89 | 32 Avg_Write_Amplification 0 0 539 |
---|
90 | 177 Drive_Life_Remain% 99 2 99 |
---|
91 | 178 Drive_Life_Remain_x100 9853 200 9853 |
---|
92 | 180 Unused_Reserved_Blk_Ct 47643 0 47643 |
---|
93 | 181 Program_Fail_Ct 0 0 0 |
---|
94 | 182 Erase_Fail_Ct 0 0 0 |
---|
95 | 190 Drive_Temp_Warning 45 65 65 |
---|
96 | 194 Drive_Temperature 45 70 65 |
---|
97 | 195 UECC_Ct 0 0 0 |
---|
98 | 198 Offline_Scan_UEC 0 0 0 |
---|
99 | 233 Number_Of_LBA_Written 335479 0 335479 |
---|
100 | 245 DriveLife_Used% 1 98 1 |
---|
101 | 246 DriveLife_Used%x100 147 9800 147 |
---|
102 | defect list format 6 unknown |
---|
103 | Elements in grown defect list: 0 |
---|
104 | |
---|
105 | Error counter log: |
---|
106 | Errors Corrected by Total Correction Gigabytes Total |
---|
107 | ECC rereads/ errors algorithm processed uncorrected |
---|
108 | fast | delayed rewrites corrected invocations [10^9 bytes] errors |
---|
109 | read: 0 0 0 0 0 1.020 0 |
---|
110 | write: 0 0 0 0 0 0.708 0 |
---|
111 | verify: 0 0 0 0 0 2.430 0 |
---|
112 | |
---|
113 | Non-medium error count: 30781 |
---|
114 | |
---|
115 | No self-tests have been logged |
---|
116 | |
---|
117 | Background scan results log |
---|
118 | Status: no scans active |
---|
119 | Accumulated power on time, hours:minutes 3396:42 [203802 minutes] |
---|
120 | Number of background scans performed: 0, scan progress: 0.00% |
---|
121 | Number of background medium scans performed: 0 |
---|
122 | |
---|
123 | # when lba(hex) [sk,asc,ascq] reassign_status |
---|
124 | 1 0:00 0000000000000000 [0,0,0] Reserved [0x0] |
---|
125 | |
---|
126 | Protocol Specific port log page for SAS SSP |
---|
127 | relative target port id = 1 |
---|
128 | generation code = 1 |
---|
129 | number of phys = 1 |
---|
130 | phy identifier = 0 |
---|
131 | attached device type: SAS or SATA device |
---|
132 | attached reason: loss of dword synchronization |
---|
133 | reason: power on |
---|
134 | negotiated logical link rate: phy enabled; 6 Gbps |
---|
135 | attached initiator port: ssp=1 stp=1 smp=1 |
---|
136 | attached target port: ssp=0 stp=0 smp=0 |
---|
137 | SAS address = 0x5001173100309155 |
---|
138 | attached SAS address = 0x500605b0091c3bf0 |
---|
139 | attached phy identifier = 4 |
---|
140 | Invalid DWORD count = 0 |
---|
141 | Running disparity error count = 0 |
---|
142 | Loss of DWORD synchronization = 0 |
---|
143 | Phy reset problem = 0 |
---|
144 | Phy event descriptors: |
---|
145 | Invalid word count: 0 |
---|
146 | Running disparity error count: 0 |
---|
147 | Loss of dword synchronization count: 0 |
---|
148 | Phy reset problem count: 0 |
---|
149 | phy identifier = 0 |
---|
150 | attached device type: no device attached |
---|
151 | attached reason: unknown |
---|
152 | reason: unknown |
---|
153 | negotiated logical link rate: phy enabled; unknown |
---|
154 | attached initiator port: ssp=0 stp=0 smp=0 |
---|
155 | attached target port: ssp=0 stp=0 smp=0 |
---|
156 | SAS address = 0x2 |
---|
157 | attached SAS address = 0x0 |
---|
158 | attached phy identifier = 0 |
---|
159 | Invalid DWORD count = 0 |
---|
160 | Running disparity error count = 4 |
---|
161 | Loss of DWORD synchronization = 0 |
---|
162 | Phy reset problem = 0 |
---|
163 | relative target port id = 2 |
---|
164 | generation code = 1 |
---|
165 | number of phys = 1 |
---|
166 | phy identifier = 1 |
---|
167 | attached device type: no device attached |
---|
168 | attached reason: unknown |
---|
169 | reason: unknown |
---|
170 | negotiated logical link rate: phy enabled; unknown |
---|
171 | attached initiator port: ssp=0 stp=0 smp=0 |
---|
172 | attached target port: ssp=0 stp=0 smp=0 |
---|
173 | SAS address = 0x5001173100309156 |
---|
174 | attached SAS address = 0x0 |
---|
175 | attached phy identifier = 0 |
---|
176 | Invalid DWORD count = 0 |
---|
177 | Running disparity error count = 0 |
---|
178 | Loss of DWORD synchronization = 0 |
---|
179 | Phy reset problem = 0 |
---|
180 | Phy event descriptors: |
---|
181 | Invalid word count: 0 |
---|
182 | Running disparity error count: 0 |
---|
183 | Loss of dword synchronization count: 0 |
---|
184 | Phy reset problem count: 0 |
---|
185 | phy identifier = 0 |
---|
186 | attached device type: no device attached |
---|
187 | attached reason: unknown |
---|
188 | reason: unknown |
---|
189 | negotiated logical link rate: phy enabled; unknown |
---|
190 | attached initiator port: ssp=0 stp=0 smp=0 |
---|
191 | attached target port: ssp=0 stp=0 smp=0 |
---|
192 | SAS address = 0x2 |
---|
193 | attached SAS address = 0x0 |
---|
194 | attached phy identifier = 0 |
---|
195 | Invalid DWORD count = 0 |
---|
196 | Running disparity error count = 4 |
---|
197 | Loss of DWORD synchronization = 0 |
---|
198 | Phy reset problem = 0 |
---|
199 | |
---|
200 | |
---|
201 | |
---|
202 | |
---|
203 | |
---|
204 | |
---|
205 | |
---|
206 | |
---|
207 | |
---|
208 | |
---|
209 | |
---|
210 | |
---|
211 | |
---|
212 | |
---|
213 | |
---|
214 | |
---|
215 | |
---|
216 | |
---|
217 | |
---|
218 | |
---|
219 | |
---|
220 | |
---|
221 | |
---|