Ticket #861: smartctl-MICRON-5100-PRO.txt

File smartctl-MICRON-5100-PRO.txt, 11.6 KB (added by Micron, 7 years ago)
Line 
1smartctl 6.5 2016-05-07 r4318 [x86_64-linux-3.10.0-514.26.1.el7.x86_64] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: Micron_5100_MTFDDAK960TCB
6Serial Number: 164914FD884A
7LU WWN Device Id: 5 00a075 114fd884a
8Firmware Version: D0MU00E
9User Capacity: 500,107,862,528 bytes [500 GB]
10Sector Sizes: 512 bytes logical, 4096 bytes physical
11Rotation Rate: Solid State Device
12Form Factor: 2.5 inches
13Device is: Not in smartctl database [for details use: -P showall]
14ATA Version is: ACS-3 T13/2161-D revision 5
15SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
16Local Time is: Thu Aug 3 15:38:30 2017 MDT
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is: Unavailable
20APM level is: 254 (maximum performance)
21Rd look-ahead is: Enabled
22Write cache is: Enabled
23ATA Security is: Disabled, NOT FROZEN [SEC1]
24Wt Cache Reorder: Enabled
25
26=== START OF READ SMART DATA SECTION ===
27SMART overall-health self-assessment test result: PASSED
28
29General SMART Values:
30Offline data collection status: (0x00) Offline data collection activity
31 was never started.
32 Auto Offline Data Collection: Disabled.
33Self-test execution status: ( 0) The previous self-test routine completed
34 without error or no self-test has ever
35 been run.
36Total time to complete Offline
37data collection: ( 1969) seconds.
38Offline data collection
39capabilities: (0x7b) SMART execute Offline immediate.
40 Auto Offline data collection on/off support.
41 Suspend Offline collection upon new
42 command.
43 Offline surface scan supported.
44 Self-test supported.
45 Conveyance Self-test supported.
46 Selective Self-test supported.
47SMART capabilities: (0x0003) Saves SMART data before entering
48 power-saving mode.
49 Supports SMART auto save timer.
50Error logging capability: (0x01) Error logging supported.
51 General Purpose Logging supported.
52Short self-test routine
53recommended polling time: ( 2) minutes.
54Extended self-test routine
55recommended polling time: ( 8) minutes.
56Conveyance self-test routine
57recommended polling time: ( 3) minutes.
58SCT capabilities: (0x0035) SCT Status supported.
59 SCT Feature Control supported.
60 SCT Data Table supported.
61
62SMART Attributes Data Structure revision number: 16
63Vendor Specific SMART Attributes with Thresholds:
64ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
65 1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
66 5 Reallocated_Sector_Ct -O--CK 100 100 001 - 0
67 9 Power_On_Hours -O--CK 100 100 001 - 75
68 12 Power_Cycle_Count -O--CK 100 100 001 - 4
69170 Unknown_Attribute PO--CK 100 100 010 - 0
70171 Unknown_Attribute -O--CK 100 100 000 - 0
71172 Unknown_Attribute -O--CK 100 100 001 - 0
72173 Unknown_Attribute -O--CK 100 100 000 - 1
73174 Unknown_Attribute -O--CK 100 100 000 - 2
74183 Runtime_Bad_Block -O--CK 100 100 000 - 0
75184 End-to-End_Error -O--CK 100 100 000 - 0
76187 Reported_Uncorrect -O--CK 100 100 000 - 0
77188 Command_Timeout -O--CK 100 100 000 - 1
78194 Temperature_Celsius -O---K 070 068 000 - 30 (Min/Max 24/32)
79195 Hardware_ECC_Recovered -O--CK 100 100 000 - 0
80196 Reallocated_Event_Count -O--CK 100 100 000 - 0
81197 Current_Pending_Sector -O--CK 100 100 000 - 0
82198 Offline_Uncorrectable ----CK 100 100 000 - 0
83199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
84202 Unknown_SSD_Attribute ----CK 100 100 001 - 0
85206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
86246 Unknown_Attribute -O--CK 100 100 000 - 0
87247 Unknown_Attribute -O--CK 100 100 000 - 0
88248 Unknown_Attribute -O--CK 100 100 000 - 145853
89180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 12168
90210 Unknown_Attribute -O--CK 100 100 000 - 0
91 ||||||_ K auto-keep
92 |||||__ C event count
93 ||||___ R error rate
94 |||____ S speed/performance
95 ||_____ O updated online
96 |______ P prefailure warning
97
98General Purpose Log Directory Version 1
99SMART Log Directory Version 1 [multi-sector log support]
100Address Access R/W Size Description
1010x00 GPL,SL R/O 1 Log Directory
1020x01 SL R/O 1 Summary SMART error log
1030x02 SL R/O 51 Comprehensive SMART error log
1040x03 GPL R/O 16383 Ext. Comprehensive SMART error log
1050x04 GPL,SL R/O 8 Device Statistics log
1060x06 SL R/O 1 SMART self-test log
1070x07 GPL R/O 1 Extended self-test log
1080x09 SL R/W 1 Selective self-test log
1090x10 GPL R/O 1 SATA NCQ Queued Error log
1100x11 GPL R/O 1 SATA Phy Event Counters log
1110x13 GPL R/O 1 SATA NCQ Send and Receive log
1120x24 GPL R/O 8000 Current Device Internal Status Data log
1130x25 GPL R/O 8000 Saved Device Internal Status Data log
1140x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
1150x80-0x9f GPL,SL R/W 16 Host vendor specific log
1160xa0 GPL VS 35328 Device vendor specific log
1170xa1 GPL,SL VS 3 Device vendor specific log
1180xa3 GPL VS 13824 Device vendor specific log
1190xa4 GPL VS 354 Device vendor specific log
1200xa4 SL VS 98 Device vendor specific log
1210xa5 GPL VS 8000 Device vendor specific log
1220xa5 SL VS 64 Device vendor specific log
1230xa6 GPL VS 8000 Device vendor specific log
1240xa6 SL VS 64 Device vendor specific log
1250xe0 GPL,SL R/W 1 SCT Command/Status
1260xe1 GPL,SL R/W 1 SCT Data Transfer
127
128SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
129No Errors Logged
130
131SMART Extended Self-test Log Version: 1 (1 sectors)
132Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
133# 1 Short offline Completed without error 00% 75 -
134# 2 Vendor (0xff) Completed without error 00% 74 -
135
136SMART Selective self-test log data structure revision number 1
137 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
138 1 0 0 Not_testing
139 2 0 0 Not_testing
140 3 0 0 Completed [00% left] (126081536-126147071)
141 4 0 0 Not_testing
142 5 0 0 Not_testing
143Selective self-test flags (0x0):
144 After scanning selected spans, do NOT read-scan remainder of disk.
145If Selective self-test is pending on power-up, resume after 0 minute delay.
146
147SCT Status Version: 3
148SCT Version (vendor specific): 1 (0x0001)
149SCT Support Level: 0
150Device State: Active (0)
151Current Temperature: 30 Celsius
152Power Cycle Min/Max Temperature: 23/30 Celsius
153Lifetime Min/Max Temperature: 23/32 Celsius
154Under/Over Temperature Limit Count: 0/0
155
156SCT Temperature History Version: 2
157Temperature Sampling Period: 1 minute
158Temperature Logging Interval: 1 minute
159Min/Max recommended Temperature: 0/70 Celsius
160Min/Max Temperature Limit: -5/75 Celsius
161Temperature History Size (Index): 478 (200)
162
163Index Estimated Time Temperature Celsius
164 201 2017-08-03 07:41 32 *************
165 ... ..(269 skipped). .. *************
166 471 2017-08-03 12:11 32 *************
167 472 2017-08-03 12:12 31 ************
168 473 2017-08-03 12:13 31 ************
169 474 2017-08-03 12:14 ? -
170 475 2017-08-03 12:15 ? -
171 476 2017-08-03 12:16 29 **********
172 477 2017-08-03 12:17 29 **********
173 0 2017-08-03 12:18 31 ************
174 ... ..( 25 skipped). .. ************
175 26 2017-08-03 12:44 31 ************
176 27 2017-08-03 12:45 32 *************
177 ... ..( 9 skipped). .. *************
178 37 2017-08-03 12:55 32 *************
179 38 2017-08-03 12:56 31 ************
180 ... ..( 40 skipped). .. ************
181 79 2017-08-03 13:37 31 ************
182 80 2017-08-03 13:38 32 *************
183 ... ..( 5 skipped). .. *************
184 86 2017-08-03 13:44 32 *************
185 87 2017-08-03 13:45 31 ************
186 ... ..( 41 skipped). .. ************
187 129 2017-08-03 14:27 31 ************
188 130 2017-08-03 14:28 32 *************
189 ... ..( 69 skipped). .. *************
190 200 2017-08-03 15:38 32 *************
191
192SCT Error Recovery Control command not supported
193
194Device Statistics (GP Log 0x04)
195Page Offset Size Value Flags Description
1960x01 ===== = = === == General Statistics (rev 1) ==
1970x01 0x008 4 4 --- Lifetime Power-On Resets
1980x01 0x010 4 75 --- Power-on Hours
1990x01 0x018 6 0 --- Logical Sectors Written
2000x01 0x020 6 0 --- Number of Write Commands
2010x01 0x028 6 952 --- Logical Sectors Read
2020x01 0x030 6 92 --- Number of Read Commands
2030x01 0x038 6 270420000 --- Date and Time TimeStamp
2040x04 ===== = = === == General Errors Statistics (rev 1) ==
2050x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
2060x04 0x010 4 1 --- Resets Between Cmd Acceptance and Completion
2070x05 ===== = = === == Temperature Statistics (rev 1) ==
2080x05 0x008 1 30 --- Current Temperature
2090x05 0x010 1 31 --- Average Short Term Temperature
2100x05 0x018 1 - --- Average Long Term Temperature
2110x05 0x020 1 32 --- Highest Temperature
2120x05 0x028 1 24 --- Lowest Temperature
2130x05 0x030 1 31 --- Highest Average Short Term Temperature
2140x05 0x038 1 31 --- Lowest Average Short Term Temperature
2150x05 0x040 1 - --- Highest Average Long Term Temperature
2160x05 0x048 1 - --- Lowest Average Long Term Temperature
2170x05 0x050 4 0 --- Time in Over-Temperature
2180x05 0x058 1 70 --- Specified Maximum Operating Temperature
2190x05 0x060 4 0 --- Time in Under-Temperature
2200x05 0x068 1 0 --- Specified Minimum Operating Temperature
2210x06 ===== = = === == Transport Statistics (rev 1) ==
2220x06 0x008 4 3 --- Number of Hardware Resets
2230x06 0x010 4 0 --- Number of ASR Events
2240x06 0x018 4 0 --- Number of Interface CRC Errors
2250x07 ===== = = === == Solid State Device Statistics (rev 1) ==
2260x07 0x008 1 0 N-- Percentage Used Endurance Indicator
227 |||_ C monitored condition met
228 ||__ D supports DSN
229 |___ N normalized value
230
231SATA Phy Event Counters (GP Log 0x11)
232ID Size Value Description
2330x0001 4 0 Command failed due to ICRC error
2340x0003 4 0 R_ERR response for device-to-host data FIS
2350x0004 4 0 R_ERR response for host-to-device data FIS
2360x0006 4 0 R_ERR response for device-to-host non-data FIS
2370x000a 4 2 Device-to-host register FISes sent due to a COMRESET
2380x000b 4 0 CRC errors within host-to-device FIS
2390x000d 4 0 Non-CRC errors within host-to-device FIS
240