Ticket #819: kingston_6.5.txt

File kingston_6.5.txt, 5.6 KB (added by mara43, 7 years ago)
Line 
1smartctl 6.5 2017-01-21 r4383 [x86_64-linux-4.4.53-223-x86_64] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: KINGSTON SUV400S37120G
6Serial Number: 50026B776500B932
7LU WWN Device Id: 0 550380 440010000
8Firmware Version: 0C3FD6SD
9User Capacity: 120,034,123,776 bytes [120 GB]
10Sector Sizes: 512 bytes logical, 4096 bytes physical
11Rotation Rate: Solid State Device
12Form Factor: M.2
13Device is: Not in smartctl database [for details use: -P showall]
14ATA Version is: Unknown(0x0ffe), ATA8-ACS T13/1699-D revision 6
15SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
16Local Time is: Fri Mar 17 08:15:12 2017 BRT
17SMART support is: Available - device has SMART capability.
18SMART support is: Enabled
19AAM feature is: Unavailable
20APM feature is: Disabled
21Rd look-ahead is: Enabled
22Write cache is: Enabled
23ATA Security is: Disabled, frozen [SEC2]
24Write SCT (Get) Feature Control Command failed: scsi error badly formed scsi parameters
25Wt Cache Reorder: Unknown (SCT Feature Control command failed)
26
27Read SMART Data failed: scsi error badly formed scsi parameters
28
29=== START OF READ SMART DATA SECTION ===
30SMART Status command failed: scsi error badly formed scsi parameters
31SMART overall-health self-assessment test result: UNKNOWN!
32SMART Status, Attributes and Thresholds cannot be read.
33
34Read SMART Log Directory failed: scsi error badly formed scsi parameters
35
36General Purpose Log Directory Version 1
37Address Access R/W Size Description
380x00 GPL R/O 1 Log Directory
390x03 GPL R/O 1 Ext. Comprehensive SMART error log
400x04 GPL R/O 8 Device Statistics log
410x07 GPL R/O 1 Extended self-test log
420x0a GPL R/W 5 Device Statistics Notification
430x10 GPL R/O 1 SATA NCQ Queued Error log
440x11 GPL R/O 1 SATA Phy Event Counters log
450x30 GPL R/O 9 IDENTIFY DEVICE data log
460x80-0x9f GPL R/W 16 Host vendor specific log
470xe0 GPL R/W 1 SCT Command/Status
480xe1 GPL R/W 1 SCT Data Transfer
49
50SMART Extended Comprehensive Error Log Version: 0 (1 sectors)
51No Errors Logged
52
53SMART Extended Self-test Log Version: 0 (1 sectors)
54No self-tests have been logged. [To run self-tests, use: smartctl -t]
55
56Selective Self-tests/Logging not supported
57
58SCT Status Version: 3
59SCT Version (vendor specific): 1 (0x0001)
60SCT Support Level: 0
61Device State: Active (0)
62Current Temperature: 38 Celsius
63Power Cycle Min/Max Temperature: 33/41 Celsius
64Lifetime Min/Max Temperature: 25/47 Celsius
65Under/Over Temperature Limit Count: 0/0
66SMART Status: 0xc24f (PASSED)
67
68Write SCT Data Table failed: scsi error badly formed scsi parameters
69Read SCT Temperature History failed
70
71Read SCT Status failed: scsi error badly formed scsi parameters
72SCT (Get) Error Recovery Control command failed
73
74Device Statistics (GP Log 0x04)
75Page Offset Size Value Flags Description
760x01 ===== = = === == General Statistics (rev 1) ==
770x01 0x008 4 27 --- Lifetime Power-On Resets
780x01 0x010 4 5185 --- Power-on Hours
790x01 0x018 6 4667344169 --- Logical Sectors Written
800x01 0x020 6 52471807 --- Number of Write Commands
810x01 0x028 6 1344744120 --- Logical Sectors Read
820x01 0x030 6 8843756 --- Number of Read Commands
830x01 0x038 6 18667904460 --- Date and Time TimeStamp
840x02 ===== = = === == Free-Fall Statistics (empty) ==
850x03 ===== = = === == Rotating Media Statistics (empty) ==
860x04 ===== = = === == General Errors Statistics (rev 1) ==
870x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
880x04 0x010 4 110 --- Resets Between Cmd Acceptance and Completion
890x05 ===== = = === == Temperature Statistics (rev 1) ==
900x05 0x008 1 38 -D- Current Temperature
910x05 0x010 1 - -D- Average Short Term Temperature
920x05 0x018 1 0 -D- Average Long Term Temperature
930x05 0x020 1 47 --- Highest Temperature
940x05 0x028 1 25 --- Lowest Temperature
950x05 0x030 1 - -D- Highest Average Short Term Temperature
960x05 0x038 1 - -D- Lowest Average Short Term Temperature
970x05 0x040 1 - -D- Highest Average Long Term Temperature
980x05 0x048 1 - -D- Lowest Average Long Term Temperature
990x05 0x050 4 0 -D- Time in Over-Temperature
1000x05 0x058 1 70 --- Specified Maximum Operating Temperature
1010x05 0x060 4 0 -D- Time in Under-Temperature
1020x05 0x068 1 0 --- Specified Minimum Operating Temperature
1030x06 ===== = = === == Transport Statistics (rev 1) ==
1040x06 0x008 4 110 --- Number of Hardware Resets
1050x06 0x018 4 0 --- Number of Interface CRC Errors
1060x07 ===== = = === == Solid State Device Statistics (rev 1) ==
1070x07 0x008 1 3 --- Percentage Used Endurance Indicator
108 |||_ C monitored condition met
109 ||__ D supports DSN
110 |___ N normalized value
111
112SATA Phy Event Counters (GP Log 0x11)
113ID Size Value Description
1140x0001 4 0 Command failed due to ICRC error
1150x000a 4 9 Device-to-host register FISes sent due to a COMRESET
116