Ticket #792: smartctl-SKHynix-SC308.txt

File smartctl-SKHynix-SC308.txt, 6.7 KB (added by wingers, 7 years ago)
Line 
1smartctl 6.5 2016-05-07 r4318 [i686-w64-mingw32-win10(64)] (sf-6.5-1)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: SK hynix SC308 SATA 128GB
6Serial Number: FI6AN02081080AB23
7Firmware Version: 30001P10
8User Capacity: 128,035,676,160 bytes [128 GB]
9Sector Sizes: 512 bytes logical, 4096 bytes physical
10Rotation Rate: Solid State Device
11Form Factor: M.2
12Device is: Not in smartctl database [for details use: -P showall]
13ATA Version is: ACS-2 (minor revision not indicated)
14SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
15Local Time is: Fri Jan 13 06:23:13 2017 GMTST
16SMART support is: Available - device has SMART capability.
17SMART support is: Enabled
18AAM feature is: Unavailable
19APM level is: 128 (minimum power consumption without standby)
20Rd look-ahead is: Enabled
21Write cache is: Enabled
22ATA Security is: Disabled, frozen [SEC2]
23Wt Cache Reorder: Unavailable
24
25=== START OF READ SMART DATA SECTION ===
26SMART overall-health self-assessment test result: PASSED
27
28General SMART Values:
29Offline data collection status: (0x02) Offline data collection activity
30 was completed without error.
31 Auto Offline Data Collection: Disabled.
32Self-test execution status: ( 4) The previous self-test routine completed
33 without error or no self-test has ever
34 been run.
35Total time to complete Offline
36data collection: ( 105) seconds.
37Offline data collection
38capabilities: (0x19) SMART execute Offline immediate.
39 No Auto Offline data collection support.
40 Suspend Offline collection upon new
41 command.
42 Offline surface scan supported.
43 Self-test supported.
44 No Conveyance Self-test supported.
45 No Selective Self-test supported.
46SMART capabilities: (0x0002) Does not save SMART data before
47 entering power-saving mode.
48 Supports SMART auto save timer.
49Error logging capability: (0x01) Error logging supported.
50 General Purpose Logging supported.
51Short self-test routine
52recommended polling time: ( 2) minutes.
53Extended self-test routine
54recommended polling time: ( 10) minutes.
55
56SMART Attributes Data Structure revision number: 0
57Vendor Specific SMART Attributes with Thresholds:
58ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
59 1 Raw_Read_Error_Rate POSR-- 166 166 006 - 0
60 5 Reallocated_Sector_Ct -O--CK 253 100 036 - 0
61 9 Power_On_Hours -O--CK 100 100 000 - 4
62 12 Power_Cycle_Count -O--CK 100 100 020 - 15
63100 Unknown_Attribute -O--CK 100 100 000 - 197324
64171 Unknown_Attribute -O--CK 253 253 000 - 0
65172 Unknown_Attribute -O--CK 253 253 000 - 0
66174 Unknown_Attribute ----CK 100 100 000 - 11
67175 Program_Fail_Count_Chip -O--CK 253 253 000 - 0
68176 Erase_Fail_Count_Chip -O--CK 253 253 000 - 0
69177 Wear_Leveling_Count -O--CK 100 100 000 - 2
70178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 000 - 31
71179 Used_Rsvd_Blk_Cnt_Tot -O--CK 100 100 000 - 152
72180 Unused_Rsvd_Blk_Cnt_Tot -O--CK 100 100 000 - 2488
73181 Program_Fail_Cnt_Total -O--CK 253 253 000 - 0
74182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0
75183 Runtime_Bad_Block -O--CK 253 253 000 - 0
76187 Reported_Uncorrect -O--CK 253 253 000 - 0
77188 Command_Timeout -O--CK 253 253 000 - 0
78191 Unknown_SSD_Attribute -O--CK 253 253 000 - 0
79194 Temperature_Celsius -O---- 029 000 000 - 29 (Min/Max 19/53)
80195 Hardware_ECC_Recovered -O--CK 253 253 000 - 0
81199 UDMA_CRC_Error_Count -O--CK 253 253 000 - 0
82201 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
83204 Soft_ECC_Correction -OSR-- 098 001 000 - 311
84231 Temperature_Celsius PO--CK 253 253 010 - 0
85234 Unknown_Attribute -O--CK 100 100 000 - 255708864
86241 Total_LBAs_Written -O--CK 100 100 000 - 209284239
87242 Total_LBAs_Read -O--CK 100 100 000 - 139077322
88250 Read_Error_Retry_Rate -O--CK 100 100 000 - 47222
89 ||||||_ K auto-keep
90 |||||__ C event count
91 ||||___ R error rate
92 |||____ S speed/performance
93 ||_____ O updated online
94 |______ P prefailure warning
95
96General Purpose Log Directory Version 1
97SMART Log Directory Version 1 [multi-sector log support]
98Address Access R/W Size Description
990x00 GPL,SL R/O 1 Log Directory
1000x01 SL R/O 1 Summary SMART error log
1010x02 SL R/O 4 Comprehensive SMART error log
1020x03 GPL R/O 5 Ext. Comprehensive SMART error log
1030x04 GPL,SL R/O 8 Device Statistics log
1040x06 SL R/O 1 SMART self-test log
1050x07 GPL R/O 2 Extended self-test log
1060x10 GPL R/O 1 SATA NCQ Queued Error log
1070x11 GPL R/O 1 SATA Phy Event Counters log
1080x30 GPL R/O 8 IDENTIFY DEVICE data log
1090x80-0x9f GPL,SL R/W 16 Host vendor specific log
110
111SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
112No Errors Logged
113
114SMART Extended Self-test Log Version: 1 (2 sectors)
115Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
116# 1 Short offline Completed without error 00% 4 -
117# 2 Short offline Completed without error 90% 0 -
118
119Selective Self-tests/Logging not supported
120
121SCT Commands not supported
122
123Device Statistics (GP Log 0x04)
124Page Offset Size Value Flags Description
1250x01 ===== = = === == General Statistics (empty) ==
1260x04 ===== = = === == General Errors Statistics (empty) ==
1270x05 ===== = = === == Temperature Statistics (empty) ==
1280x06 ===== = = === == Transport Statistics (empty) ==
1290x07 ===== = = === == Solid State Device Statistics (empty) ==
130 |||_ C monitored condition met
131 ||__ D supports DSN
132 |___ N normalized value
133
134SATA Phy Event Counters (GP Log 0x11)
135ID Size Value Description
1360x0001 2 0 Command failed due to ICRC error
1370x000a 2 8 Device-to-host register FISes sent due to a COMRESET
138