| 1 | smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build)
|
|---|
| 2 | Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
|
|---|
| 3 |
|
|---|
| 4 | === START OF INFORMATION SECTION ===
|
|---|
| 5 | Device Model: ST1000DX002-2DV162
|
|---|
| 6 | Firmware Version: CC41
|
|---|
| 7 | User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
|---|
| 8 | Sector Sizes: 512 bytes logical, 4096 bytes physical
|
|---|
| 9 | Device is: Not in smartctl database [for details use: -P showall]
|
|---|
| 10 | ATA Version is: 9
|
|---|
| 11 | ATA Standard is: Not recognized. Minor revision code: 0x001f
|
|---|
| 12 | Local Time is: Mon Jan 2 16:55:41 2017 CST
|
|---|
| 13 | SMART support is: Available - device has SMART capability.
|
|---|
| 14 | SMART support is: Enabled
|
|---|
| 15 |
|
|---|
| 16 | === START OF READ SMART DATA SECTION ===
|
|---|
| 17 | SMART overall-health self-assessment test result: PASSED
|
|---|
| 18 |
|
|---|
| 19 | General SMART Values:
|
|---|
| 20 | Offline data collection status: (0x00) Offline data collection activity
|
|---|
| 21 | was never started.
|
|---|
| 22 | Auto Offline Data Collection: Disabled.
|
|---|
| 23 | Self-test execution status: ( 0) The previous self-test routine completed
|
|---|
| 24 | without error or no self-test has ever
|
|---|
| 25 | been run.
|
|---|
| 26 | Total time to complete Offline
|
|---|
| 27 | data collection: ( 0) seconds.
|
|---|
| 28 | Offline data collection
|
|---|
| 29 | capabilities: (0x73) SMART execute Offline immediate.
|
|---|
| 30 | Auto Offline data collection on/off support.
|
|---|
| 31 | Suspend Offline collection upon new
|
|---|
| 32 | command.
|
|---|
| 33 | No Offline surface scan supported.
|
|---|
| 34 | Self-test supported.
|
|---|
| 35 | Conveyance Self-test supported.
|
|---|
| 36 | Selective Self-test supported.
|
|---|
| 37 | SMART capabilities: (0x0003) Saves SMART data before entering
|
|---|
| 38 | power-saving mode.
|
|---|
| 39 | Supports SMART auto save timer.
|
|---|
| 40 | Error logging capability: (0x01) Error logging supported.
|
|---|
| 41 | General Purpose Logging supported.
|
|---|
| 42 | Short self-test routine
|
|---|
| 43 | recommended polling time: ( 1) minutes.
|
|---|
| 44 | Extended self-test routine
|
|---|
| 45 | recommended polling time: ( 105) minutes.
|
|---|
| 46 | Conveyance self-test routine
|
|---|
| 47 | recommended polling time: ( 2) minutes.
|
|---|
| 48 | SCT capabilities: (0x1081) SCT Status supported.
|
|---|
| 49 |
|
|---|
| 50 | SMART Attributes Data Structure revision number: 10
|
|---|
| 51 | Vendor Specific SMART Attributes with Thresholds:
|
|---|
| 52 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|---|
| 53 | 1 Raw_Read_Error_Rate 0x000f 100 100 006 Pre-fail Always - 39656
|
|---|
| 54 | 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0
|
|---|
| 55 | 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 1
|
|---|
| 56 | 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
|---|
| 57 | 7 Seek_Error_Rate 0x000f 100 253 030 Pre-fail Always - 17599
|
|---|
| 58 | 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 0
|
|---|
| 59 | 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
|
|---|
| 60 | 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 1
|
|---|
| 61 | 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
|
|---|
| 62 | 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
|
|---|
| 63 | 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
|---|
| 64 | 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
|
|---|
| 65 | 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
|
|---|
| 66 | 190 Airflow_Temperature_Cel 0x0022 069 069 045 Old_age Always - 31 (Min/Max 22/31)
|
|---|
| 67 | 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
|
|---|
| 68 | 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1
|
|---|
| 69 | 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 2
|
|---|
| 70 | 194 Temperature_Celsius 0x0022 031 040 000 Old_age Always - 31 (0 22 0 0)
|
|---|
| 71 | 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
|---|
| 72 | 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
|
|---|
| 73 | 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
|
|---|
| 74 | 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 225558797484032
|
|---|
| 75 | 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 41648744
|
|---|
| 76 | 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 5347
|
|---|
| 77 |
|
|---|
| 78 | SMART Error Log Version: 1
|
|---|
| 79 | No Errors Logged
|
|---|
| 80 |
|
|---|
| 81 | SMART Self-test log structure revision number 1
|
|---|
| 82 | No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|---|
| 83 |
|
|---|
| 84 |
|
|---|
| 85 | SMART Selective self-test log data structure revision number 1
|
|---|
| 86 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|---|
| 87 | 1 0 0 Not_testing
|
|---|
| 88 | 2 0 0 Not_testing
|
|---|
| 89 | 3 0 0 Not_testing
|
|---|
| 90 | 4 0 0 Not_testing
|
|---|
| 91 | 5 0 0 Not_testing
|
|---|
| 92 | Selective self-test flags (0x0):
|
|---|
| 93 | After scanning selected spans, do NOT read-scan remainder of disk.
|
|---|
| 94 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|---|
| 95 |
|
|---|