Ticket #789: smart-sdc-4hrs-test.txt

File smart-sdc-4hrs-test.txt, 5.0 KB (added by mroberds, 5 years ago)

smartctl -a after about four hours of runtime AND one short self-test

Line 
1smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-4-amd64] (local build)
2Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
3
4=== START OF INFORMATION SECTION ===
5Device Model:     ST1000DX002-2DV162
6Firmware Version: CC41
7User Capacity:    1,000,204,886,016 bytes [1.00 TB]
8Sector Sizes:     512 bytes logical, 4096 bytes physical
9Device is:        Not in smartctl database [for details use: -P showall]
10ATA Version is:   9
11ATA Standard is:  Not recognized. Minor revision code: 0x001f
12Local Time is:    Mon Jan  2 20:06:56 2017 CST
13SMART support is: Available - device has SMART capability.
14SMART support is: Enabled
15
16=== START OF READ SMART DATA SECTION ===
17SMART overall-health self-assessment test result: PASSED
18
19General SMART Values:
20Offline data collection status:  (0x82) Offline data collection activity
21                                        was completed without error.
22                                        Auto Offline Data Collection: Enabled.
23Self-test execution status:      (   0) The previous self-test routine completed
24                                        without error or no self-test has ever
25                                        been run.
26Total time to complete Offline
27data collection:                (    0) seconds.
28Offline data collection
29capabilities:                    (0x7b) SMART execute Offline immediate.
30                                        Auto Offline data collection on/off support.
31                                        Suspend Offline collection upon new
32                                        command.
33                                        Offline surface scan supported.
34                                        Self-test supported.
35                                        Conveyance Self-test supported.
36                                        Selective Self-test supported.
37SMART capabilities:            (0x0003) Saves SMART data before entering
38                                        power-saving mode.
39                                        Supports SMART auto save timer.
40Error logging capability:        (0x01) Error logging supported.
41                                        General Purpose Logging supported.
42Short self-test routine
43recommended polling time:        (   1) minutes.
44Extended self-test routine
45recommended polling time:        ( 105) minutes.
46Conveyance self-test routine
47recommended polling time:        (   2) minutes.
48SCT capabilities:              (0x1081) SCT Status supported.
49
50SMART Attributes Data Structure revision number: 10
51Vendor Specific SMART Attributes with Thresholds:
52ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
53  1 Raw_Read_Error_Rate     0x000f   103   100   006    Pre-fail  Always       -       5501832
54  3 Spin_Up_Time            0x0003   100   100   000    Pre-fail  Always       -       0
55  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       1
56  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
57  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always       -       76364
58  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       4
59 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
60 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       1
61183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
62184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
63187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
64188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
65189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
66190 Airflow_Temperature_Cel 0x0022   068   067   045    Old_age   Always       -       32 (Min/Max 22/33)
67191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       0
68192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       1
69193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       5
70194 Temperature_Celsius     0x0022   032   040   000    Old_age   Always       -       32 (0 22 0 0)
71197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
72198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
73199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
74240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       57964878626819
75241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       233958440
76242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       2379893
77
78SMART Error Log Version: 1
79No Errors Logged
80
81SMART Self-test log structure revision number 1
82Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
83# 1  Short offline       Completed without error       00%         3         -
84
85SMART Selective self-test log data structure revision number 1
86 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
87    1        0        0  Not_testing
88    2        0        0  Not_testing
89    3        0        0  Not_testing
90    4        0        0  Not_testing
91    5        0        0  Not_testing
92Selective self-test flags (0x0):
93  After scanning selected spans, do NOT read-scan remainder of disk.
94If Selective self-test is pending on power-up, resume after 0 minute delay.
95