1 | smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.4.26-unRAID] (local build)
|
---|
2 | Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: ST6000VN0041-2EL11C
|
---|
6 | Firmware Version: SC61
|
---|
7 | User Capacity: 6,001,175,126,016 bytes [6.00 TB]
|
---|
8 | Sector Sizes: 512 bytes logical, 4096 bytes physical
|
---|
9 | Rotation Rate: 7200 rpm
|
---|
10 | Form Factor: 3.5 inches
|
---|
11 | Device is: Not in smartctl database [for details use: -P showall]
|
---|
12 | ATA Version is: ACS-3 T13/2161-D revision 5
|
---|
13 | SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
---|
14 | Local Time is: Wed Nov 2 10:26:19 2016 EDT
|
---|
15 | SMART support is: Available - device has SMART capability.
|
---|
16 | SMART support is: Enabled
|
---|
17 | AAM feature is: Unavailable
|
---|
18 | APM feature is: Unavailable
|
---|
19 | Rd look-ahead is: Enabled
|
---|
20 | Write cache is: Enabled
|
---|
21 | ATA Security is: Disabled, frozen [SEC2]
|
---|
22 | Wt Cache Reorder: Enabled
|
---|
23 |
|
---|
24 | === START OF READ SMART DATA SECTION ===
|
---|
25 | SMART overall-health self-assessment test result: PASSED
|
---|
26 |
|
---|
27 | General SMART Values:
|
---|
28 | Offline data collection status: (0x82) Offline data collection activity
|
---|
29 | was completed without error.
|
---|
30 | Auto Offline Data Collection: Enabled.
|
---|
31 | Self-test execution status: ( 0) The previous self-test routine completed
|
---|
32 | without error or no self-test has ever
|
---|
33 | been run.
|
---|
34 | Total time to complete Offline
|
---|
35 | data collection: ( 575) seconds.
|
---|
36 | Offline data collection
|
---|
37 | capabilities: (0x7b) SMART execute Offline immediate.
|
---|
38 | Auto Offline data collection on/off support.
|
---|
39 | Suspend Offline collection upon new
|
---|
40 | command.
|
---|
41 | Offline surface scan supported.
|
---|
42 | Self-test supported.
|
---|
43 | Conveyance Self-test supported.
|
---|
44 | Selective Self-test supported.
|
---|
45 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
46 | power-saving mode.
|
---|
47 | Supports SMART auto save timer.
|
---|
48 | Error logging capability: (0x01) Error logging supported.
|
---|
49 | General Purpose Logging supported.
|
---|
50 | Short self-test routine
|
---|
51 | recommended polling time: ( 1) minutes.
|
---|
52 | Extended self-test routine
|
---|
53 | recommended polling time: ( 574) minutes.
|
---|
54 | Conveyance self-test routine
|
---|
55 | recommended polling time: ( 2) minutes.
|
---|
56 | SCT capabilities: (0x50bd) SCT Status supported.
|
---|
57 | SCT Error Recovery Control supported.
|
---|
58 | SCT Feature Control supported.
|
---|
59 | SCT Data Table supported.
|
---|
60 |
|
---|
61 | SMART Attributes Data Structure revision number: 10
|
---|
62 | Vendor Specific SMART Attributes with Thresholds:
|
---|
63 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
---|
64 | 1 Raw_Read_Error_Rate POSR-- 100 067 044 - 326768
|
---|
65 | 3 Spin_Up_Time PO---- 094 094 000 - 0
|
---|
66 | 4 Start_Stop_Count -O--CK 100 100 020 - 3
|
---|
67 | 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
---|
68 | 7 Seek_Error_Rate POSR-- 068 060 045 - 6318110
|
---|
69 | 9 Power_On_Hours -O--CK 100 100 000 - 23 (31 208 0)
|
---|
70 | 10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
---|
71 | 12 Power_Cycle_Count -O--CK 100 100 020 - 1
|
---|
72 | 184 End-to-End_Error -O--CK 100 100 099 - 0
|
---|
73 | 187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
---|
74 | 188 Command_Timeout -O--CK 100 100 000 - 0
|
---|
75 | 189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
---|
76 | 190 Airflow_Temperature_Cel -O---K 055 051 040 - 45 (Min/Max 19/49)
|
---|
77 | 191 G-Sense_Error_Rate -O--CK 100 100 000 - 755
|
---|
78 | 192 Power-Off_Retract_Count -O--CK 100 100 000 - 0
|
---|
79 | 193 Load_Cycle_Count -O--CK 100 100 000 - 4
|
---|
80 | 194 Temperature_Celsius -O---K 045 049 000 - 45 (0 19 0 0 0)
|
---|
81 | 195 Hardware_ECC_Recovered -O-RC- 100 006 000 - 326768
|
---|
82 | 197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
---|
83 | 198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
---|
84 | 199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
---|
85 | 240 Head_Flying_Hours ------ 100 253 000 - 23 (156 65 0)
|
---|
86 | 241 Total_LBAs_Written ------ 100 253 000 - 15064042648
|
---|
87 | 242 Total_LBAs_Read ------ 100 253 000 - 1466623333
|
---|
88 | ||||||_ K auto-keep
|
---|
89 | |||||__ C event count
|
---|
90 | ||||___ R error rate
|
---|
91 | |||____ S speed/performance
|
---|
92 | ||_____ O updated online
|
---|
93 | |______ P prefailure warning
|
---|
94 |
|
---|
95 | General Purpose Log Directory Version 1
|
---|
96 | SMART Log Directory Version 1 [multi-sector log support]
|
---|
97 | Address Access R/W Size Description
|
---|
98 | 0x00 GPL,SL R/O 1 Log Directory
|
---|
99 | 0x01 SL R/O 1 Summary SMART error log
|
---|
100 | 0x02 SL R/O 5 Comprehensive SMART error log
|
---|
101 | 0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
---|
102 | 0x04 GPL,SL R/O 8 Device Statistics log
|
---|
103 | 0x06 SL R/O 1 SMART self-test log
|
---|
104 | 0x07 GPL R/O 1 Extended self-test log
|
---|
105 | 0x08 GPL R/O 2 Power Conditions log
|
---|
106 | 0x09 SL R/W 1 Selective self-test log
|
---|
107 | 0x0c GPL R/O 2048 Pending Defects log
|
---|
108 | 0x10 GPL R/O 1 SATA NCQ Queued Error log
|
---|
109 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
---|
110 | 0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
---|
111 | 0x15 GPL R/W 1 SATA Rebuild Assist log
|
---|
112 | 0x21 GPL R/O 1 Write stream error log
|
---|
113 | 0x22 GPL R/O 1 Read stream error log
|
---|
114 | 0x24 GPL R/O 512 Current Device Internal Status Data log
|
---|
115 | 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
---|
116 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
---|
117 | 0xa1 GPL,SL VS 24 Device vendor specific log
|
---|
118 | 0xa2 GPL VS 8160 Device vendor specific log
|
---|
119 | 0xa6 GPL VS 192 Device vendor specific log
|
---|
120 | 0xa8-0xa9 GPL,SL VS 136 Device vendor specific log
|
---|
121 | 0xab GPL VS 1 Device vendor specific log
|
---|
122 | 0xad GPL VS 16 Device vendor specific log
|
---|
123 | 0xb0 GPL VS 9048 Device vendor specific log
|
---|
124 | 0xbe-0xbf GPL VS 65535 Device vendor specific log
|
---|
125 | 0xc1 GPL,SL VS 16 Device vendor specific log
|
---|
126 | 0xc3 GPL,SL VS 8 Device vendor specific log
|
---|
127 | 0xd1 GPL VS 264 Device vendor specific log
|
---|
128 | 0xd2 GPL VS 10000 Device vendor specific log
|
---|
129 | 0xd4 GPL VS 2048 Device vendor specific log
|
---|
130 | 0xda GPL,SL VS 1 Device vendor specific log
|
---|
131 | 0xe0 GPL,SL R/W 1 SCT Command/Status
|
---|
132 | 0xe1 GPL,SL R/W 1 SCT Data Transfer
|
---|
133 |
|
---|
134 | SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
---|
135 | No Errors Logged
|
---|
136 |
|
---|
137 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
---|
138 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
---|
139 | # 1 Short offline Completed without error 00% 23 -
|
---|
140 |
|
---|
141 | SMART Selective self-test log data structure revision number 1
|
---|
142 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
---|
143 | 1 0 0 Not_testing
|
---|
144 | 2 0 0 Not_testing
|
---|
145 | 3 0 0 Not_testing
|
---|
146 | 4 0 0 Not_testing
|
---|
147 | 5 0 0 Not_testing
|
---|
148 | Selective self-test flags (0x0):
|
---|
149 | After scanning selected spans, do NOT read-scan remainder of disk.
|
---|
150 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
---|
151 |
|
---|
152 | SCT Status Version: 3
|
---|
153 | SCT Version (vendor specific): 522 (0x020a)
|
---|
154 | SCT Support Level: 1
|
---|
155 | Device State: Active (0)
|
---|
156 | Current Temperature: 44 Celsius
|
---|
157 | Power Cycle Min/Max Temperature: 18/49 Celsius
|
---|
158 | Lifetime Min/Max Temperature: 18/49 Celsius
|
---|
159 | Under/Over Temperature Limit Count: 0/24
|
---|
160 |
|
---|
161 | SCT Temperature History Version: 2
|
---|
162 | Temperature Sampling Period: 3 minutes
|
---|
163 | Temperature Logging Interval: 59 minutes
|
---|
164 | Min/Max recommended Temperature: 0/ 0 Celsius
|
---|
165 | Min/Max Temperature Limit: 0/ 0 Celsius
|
---|
166 | Temperature History Size (Index): 128 (24)
|
---|
167 |
|
---|
168 | Index Estimated Time Temperature Celsius
|
---|
169 | 25 2016-10-28 05:06 ? -
|
---|
170 | ... ..(102 skipped). .. -
|
---|
171 | 0 2016-11-01 10:23 ? -
|
---|
172 | 1 2016-11-01 11:22 18 -
|
---|
173 | 2 2016-11-01 12:21 45 **************************
|
---|
174 | 3 2016-11-01 13:20 49 ******************************
|
---|
175 | 4 2016-11-01 14:19 48 *****************************
|
---|
176 | ... ..( 2 skipped). .. *****************************
|
---|
177 | 7 2016-11-01 17:16 48 *****************************
|
---|
178 | 8 2016-11-01 18:15 47 ****************************
|
---|
179 | 9 2016-11-01 19:14 48 *****************************
|
---|
180 | ... ..( 2 skipped). .. *****************************
|
---|
181 | 12 2016-11-01 22:11 48 *****************************
|
---|
182 | 13 2016-11-01 23:10 47 ****************************
|
---|
183 | ... ..( 4 skipped). .. ****************************
|
---|
184 | 18 2016-11-02 04:05 47 ****************************
|
---|
185 | 19 2016-11-02 05:04 48 *****************************
|
---|
186 | 20 2016-11-02 06:03 47 ****************************
|
---|
187 | ... ..( 2 skipped). .. ****************************
|
---|
188 | 23 2016-11-02 09:00 47 ****************************
|
---|
189 | 24 2016-11-02 09:59 46 ***************************
|
---|
190 |
|
---|
191 | SCT Error Recovery Control:
|
---|
192 | Read: 70 (7.0 seconds)
|
---|
193 | Write: 70 (7.0 seconds)
|
---|
194 |
|
---|
195 | Device Statistics (GP Log 0x04)
|
---|
196 | Page Offset Size Value Flags Description
|
---|
197 | 0x01 ===== = = === == General Statistics (rev 1) ==
|
---|
198 | 0x01 0x008 4 1 --- Lifetime Power-On Resets
|
---|
199 | 0x01 0x010 4 23 --- Power-on Hours
|
---|
200 | 0x01 0x018 6 15064042648 --- Logical Sectors Written
|
---|
201 | 0x01 0x020 6 14514252 --- Number of Write Commands
|
---|
202 | 0x01 0x028 6 1466623333 --- Logical Sectors Read
|
---|
203 | 0x01 0x030 6 1436295 --- Number of Read Commands
|
---|
204 | 0x01 0x038 6 - --- Date and Time TimeStamp
|
---|
205 | 0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
---|
206 | 0x03 0x008 4 23 --- Spindle Motor Power-on Hours
|
---|
207 | 0x03 0x010 4 0 --- Head Flying Hours
|
---|
208 | 0x03 0x018 4 4 --- Head Load Events
|
---|
209 | 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
---|
210 | 0x03 0x028 4 0 --- Read Recovery Attempts
|
---|
211 | 0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
---|
212 | 0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
---|
213 | 0x03 0x040 4 0 --- Number of High Priority Unload Events
|
---|
214 | 0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
---|
215 | 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
---|
216 | 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
---|
217 | 0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
---|
218 | 0x05 0x008 1 44 --- Current Temperature
|
---|
219 | 0x05 0x010 1 - --- Average Short Term Temperature
|
---|
220 | 0x05 0x018 1 - --- Average Long Term Temperature
|
---|
221 | 0x05 0x020 1 64 NDC+ Highest Temperature
|
---|
222 | 0x05 0x028 1 29 --- Lowest Temperature
|
---|
223 | 0x05 0x030 1 - --- Highest Average Short Term Temperature
|
---|
224 | 0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
---|
225 | 0x05 0x040 1 - --- Highest Average Long Term Temperature
|
---|
226 | 0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
---|
227 | 0x05 0x050 4 10 --- Time in Over-Temperature
|
---|
228 | 0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
---|
229 | 0x05 0x060 4 0 --- Time in Under-Temperature
|
---|
230 | 0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
---|
231 | 0x06 ===== = = === == Transport Statistics (rev 1) ==
|
---|
232 | 0x06 0x008 4 2 --- Number of Hardware Resets
|
---|
233 | 0x06 0x010 4 0 --- Number of ASR Events
|
---|
234 | 0x06 0x018 4 0 --- Number of Interface CRC Errors
|
---|
235 | |||_ C monitored condition met
|
---|
236 | ||__ D supports DSN
|
---|
237 | |___ N normalized value
|
---|
238 |
|
---|
239 | SATA Phy Event Counters (GP Log 0x11)
|
---|
240 | ID Size Value Description
|
---|
241 | 0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
---|
242 | 0x0001 2 0 Command failed due to ICRC error
|
---|
243 | 0x0003 2 0 R_ERR response for device-to-host data FIS
|
---|
244 | 0x0004 2 0 R_ERR response for host-to-device data FIS
|
---|
245 | 0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
---|
246 | 0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
---|
247 |
|
---|