Ticket #759: smartctl-Transcend-MSA630.txt

File smartctl-Transcend-MSA630.txt, 5.4 KB (added by Nimloth, 4 years ago)

smartctl report

Line 
1smartctl 6.5 2016-05-07 r4318 [FreeBSD 11.0-RELEASE-p2 amd64] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model:     TS32GMSA630
6Serial Number:    90183488D08099000029
7Firmware Version: N0113E1
8User Capacity:    32,017,047,552 bytes [32.0 GB]
9Sector Size:      512 bytes logical/physical
10Rotation Rate:    Solid State Device
11Device is:        Not in smartctl database [for details use: -P showall]
12ATA Version is:   ACS-2 (minor revision not indicated)
13SATA Version is:  SATA 3.0, 3.0 Gb/s
14Local Time is:    Sat Oct 29 17:20:31 2016 UTC
15SMART support is: Available - device has SMART capability.
16SMART support is: Enabled
17AAM feature is:   Unavailable
18APM feature is:   Unavailable
19Rd look-ahead is: Unavailable
20Write cache is:   Enabled
21ATA Security is:  Disabled, NOT FROZEN [SEC1]
22Wt Cache Reorder: Unavailable
23
24=== START OF READ SMART DATA SECTION ===
25SMART overall-health self-assessment test result: PASSED
26See vendor-specific Attribute list for marginal Attributes.
27
28General SMART Values:
29Offline data collection status:  (0x02) Offline data collection activity
30                                        was completed without error.
31                                        Auto Offline Data Collection: Disabled.
32Total time to complete Offline
33data collection:                (    1) seconds.
34Offline data collection
35capabilities:                    (0x00)         Offline data collection not supported.
36SMART capabilities:            (0x0002) Does not save SMART data before
37                                        entering power-saving mode.
38                                        Supports SMART auto save timer.
39Error logging capability:        (0x00) Error logging NOT supported.
40                                        General Purpose Logging supported.
41
42SMART Attributes Data Structure revision number: 1
43Vendor Specific SMART Attributes with Thresholds:
44ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
45  1 Raw_Read_Error_Rate     ------   100   100   000    -    0
46  5 Reallocated_Sector_Ct   ------   100   100   000    -    0
47  9 Power_On_Hours          ------   100   100   000    -    0
48192 Power-Off_Retract_Count ------   100   100   000    -    0
49194 Temperature_Celsius     ------   100   100   000    -    27
50195 Hardware_ECC_Recovered  ------   100   100   000    -    0
51196 Reallocated_Event_Count ------   100   100   016    -    0
52198 Offline_Uncorrectable   ------   100   100   050    -    0
53199 UDMA_CRC_Error_Count    ------   100   100   050    -    0
54 12 Power_Cycle_Count       ------   100   100   000    -    7
55241 Total_LBAs_Written      ------   100   100   000    -    146
56242 Total_LBAs_Read         ------   100   100   000    -    105
57160 Unknown_Attribute       ------   100   100   000    -    0
58161 Unknown_Attribute       ------   100   100   000    -    219
59163 Unknown_Attribute       ------   100   100   000    -    7
60164 Unknown_Attribute       ------   100   100   000    -    678
61165 Unknown_Attribute       ------   100   100   050    -    4
62166 Unknown_Attribute       ------   100   100   050    -    0
63167 Unknown_Attribute       ------   100   100   100    NOW  0
64                            ||||||_ K auto-keep
65                            |||||__ C event count
66                            ||||___ R error rate
67                            |||____ S speed/performance
68                            ||_____ O updated online
69                            |______ P prefailure warning
70
71General Purpose Log Directory Version 1
72SMART           Log Directory Version 1 [multi-sector log support]
73Address    Access  R/W   Size  Description
740x00       GPL,SL  R/O      1  Log Directory
750x01       GPL,SL  R/O      1  Summary SMART error log
760x02       GPL,SL  R/O      1  Comprehensive SMART error log
770x04       GPL,SL  R/O      8  Device Statistics log
780x06       GPL,SL  R/O      1  SMART self-test log
790x10       GPL,SL  R/O      1  SATA NCQ Queued Error log
800x80-0x9f  GPL,SL  R/W      1  Host vendor specific log
81
82SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
83
84SMART Error Log Version: 1
85No Errors Logged
86
87SMART Extended Self-test Log (GP Log 0x07) not supported
88
89SMART Self-test log structure revision number 1
90No self-tests have been logged.  [To run self-tests, use: smartctl -t]
91
92Selective Self-tests/Logging not supported
93
94SCT Commands not supported
95
96Device Statistics (GP Log 0x04)
97Page  Offset Size        Value Flags Description
980x01  =====  =               =  ===  == General Statistics (rev 2) ==
990x01  0x008  4               7  ---  Lifetime Power-On Resets
1000x01  0x010  4               0  ---  Power-on Hours
1010x01  0x018  6         9594656  ---  Logical Sectors Written
1020x01  0x020  6               0  ---  Number of Write Commands
1030x01  0x028  6         6910021  ---  Logical Sectors Read
1040x01  0x030  6               0  ---  Number of Read Commands
1050x02  =====  =               =  ===  == Free-Fall Statistics (empty) ==
1060x03  =====  =               =  ===  == Rotating Media Statistics (empty) ==
1070x04  =====  =               =  ===  == General Errors Statistics (empty) ==
1080x05  =====  =               =  ===  == Temperature Statistics (empty) ==
1090x06  =====  =               =  ===  == Transport Statistics (empty) ==
1100x07  =====  =               =  ===  == Solid State Device Statistics (rev 1) ==
1110x07  0x008  1               0  ---  Percentage Used Endurance Indicator
112                                |||_ C monitored condition met
113                                ||__ D supports DSN
114                                |___ N normalized value
115
116SATA Phy Event Counters (GP Log 0x11) not supported
117