Ticket #757: smartctl-WDC-WD80EZZX-11CSGA0.txt

File smartctl-WDC-WD80EZZX-11CSGA0.txt, 12.2 KB (added by ivantech, 3 years ago)

smartctl -x output

Line 
1smartctl 6.5 2016-05-07 r4318 [FreeBSD 10.3-RELEASE-p9 amd64] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model:     WDC WD80EZZX-11CSGA0
6Firmware Version: 83.H0A03
7User Capacity:    8,001,563,222,016 bytes [8.00 TB]
8Sector Sizes:     512 bytes logical, 4096 bytes physical
9Rotation Rate:    5400 rpm
10Form Factor:      3.5 inches
11Device is:        Not in smartctl database [for details use: -P showall]
12ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 4
13SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
14Local Time is:    Fri Oct 28 13:43:15 2016 CEST
15SMART support is: Available - device has SMART capability.
16SMART support is: Enabled
17AAM feature is:   Unavailable
18APM feature is:   Disabled
19Rd look-ahead is: Enabled
20Write cache is:   Enabled
21ATA Security is:  Disabled, NOT FROZEN [SEC1]
22Wt Cache Reorder: Enabled
23
24=== START OF READ SMART DATA SECTION ===
25SMART overall-health self-assessment test result: PASSED
26
27General SMART Values:
28Offline data collection status:  (0x84) Offline data collection activity
29                                        was suspended by an interrupting command from host.
30                                        Auto Offline Data Collection: Enabled.
31Self-test execution status:      (   0) The previous self-test routine completed
32                                        without error or no self-test has ever
33                                        been run.
34Total time to complete Offline
35data collection:                (  101) seconds.
36Offline data collection
37capabilities:                    (0x5b) SMART execute Offline immediate.
38                                        Auto Offline data collection on/off support.
39                                        Suspend Offline collection upon new
40                                        command.
41                                        Offline surface scan supported.
42                                        Self-test supported.
43                                        No Conveyance Self-test supported.
44                                        Selective Self-test supported.
45SMART capabilities:            (0x0003) Saves SMART data before entering
46                                        power-saving mode.
47                                        Supports SMART auto save timer.
48Error logging capability:        (0x01) Error logging supported.
49                                        General Purpose Logging supported.
50Short self-test routine
51recommended polling time:        (   2) minutes.
52Extended self-test routine
53recommended polling time:        (1334) minutes.
54SCT capabilities:              (0x003d) SCT Status supported.
55                                        SCT Error Recovery Control supported.
56                                        SCT Feature Control supported.
57                                        SCT Data Table supported.
58
59SMART Attributes Data Structure revision number: 16
60Vendor Specific SMART Attributes with Thresholds:
61ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
62  1 Raw_Read_Error_Rate     PO-R--   100   100   016    -    0
63  2 Throughput_Performance  P-S---   131   131   054    -    116
64  3 Spin_Up_Time            POS---   171   171   024    -    422 (Average 348)
65  4 Start_Stop_Count        -O--C-   100   100   000    -    16
66  5 Reallocated_Sector_Ct   PO--CK   100   100   005    -    0
67  7 Seek_Error_Rate         PO-R--   100   100   067    -    0
68  8 Seek_Time_Performance   P-S---   128   128   020    -    18
69  9 Power_On_Hours          -O--C-   100   100   000    -    206
70 10 Spin_Retry_Count        PO--C-   100   100   060    -    0
71 12 Power_Cycle_Count       -O--CK   100   100   000    -    16
72 22 Unknown_Attribute       PO---K   100   100   025    -    100
73192 Power-Off_Retract_Count -O--CK   100   100   000    -    20
74193 Load_Cycle_Count        -O--C-   100   100   000    -    20
75194 Temperature_Celsius     -O----   115   115   000    -    52 (Min/Max 21/54)
76196 Reallocated_Event_Count -O--CK   100   100   000    -    0
77197 Current_Pending_Sector  -O---K   100   100   000    -    0
78198 Offline_Uncorrectable   ---R--   100   100   000    -    0
79199 UDMA_CRC_Error_Count    -O-R--   200   200   000    -    1
80                            ||||||_ K auto-keep
81                            |||||__ C event count
82                            ||||___ R error rate
83                            |||____ S speed/performance
84                            ||_____ O updated online
85                            |______ P prefailure warning
86
87General Purpose Log Directory Version 1
88SMART           Log Directory Version 1 [multi-sector log support]
89Address    Access  R/W   Size  Description
900x00       GPL,SL  R/O      1  Log Directory
910x01           SL  R/O      1  Summary SMART error log
920x02           SL  R/O      1  Comprehensive SMART error log
930x03       GPL     R/O      1  Ext. Comprehensive SMART error log
940x04       GPL,SL  R/O      8  Device Statistics log
950x06           SL  R/O      1  SMART self-test log
960x07       GPL     R/O      1  Extended self-test log
970x08       GPL     R/O      2  Power Conditions log
980x09           SL  R/W      1  Selective self-test log
990x10       GPL     R/O      1  SATA NCQ Queued Error log
1000x11       GPL     R/O      1  SATA Phy Event Counters log
1010x12       GPL     R/O      1  SATA NCQ NON-DATA log
1020x15       GPL,SL  R/W      1  SATA Rebuild Assist log
1030x21       GPL     R/O      1  Write stream error log
1040x22       GPL     R/O      1  Read stream error log
1050x24       GPL     R/O    256  Current Device Internal Status Data log
1060x25       GPL     R/O    256  Saved Device Internal Status Data log
1070x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
1080x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
1090xe0       GPL,SL  R/W      1  SCT Command/Status
1100xe1       GPL,SL  R/W      1  SCT Data Transfer
111
112SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
113Device Error Count: 1
114        CR     = Command Register
115        FEATR  = Features Register
116        COUNT  = Count (was: Sector Count) Register
117        LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
118        LH     = LBA High (was: Cylinder High) Register    ]   LBA
119        LM     = LBA Mid (was: Cylinder Low) Register      ] Register
120        LL     = LBA Low (was: Sector Number) Register     ]
121        DV     = Device (was: Device/Head) Register
122        DC     = Device Control Register
123        ER     = Error register
124        ST     = Status register
125Powered_Up_Time is measured from power on, and printed as
126DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
127SS=sec, and sss=millisec. It "wraps" after 49.710 days.
128
129Error 1 [0] occurred at disk power-on lifetime: 170 hours (7 days + 2 hours)
130  When the command that caused the error occurred, the device was active or idle.
131
132  After command completion occurred, registers were:
133  ER -- ST COUNT  LBA_48  LH LM LL DV DC
134  -- -- -- == -- == == == -- -- -- -- --
135  84 -- 51 00 01 00 00 ec 40 f6 be 40 00  Error: ICRC, ABRT 1 sectors at LBA = 0xec40f6be = 3963680446
136
137  Commands leading to the command that caused the error were:
138  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
139  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
140  35 00 d5 01 00 00 00 ec 40 f5 c0 40 00     02:55:18.633  WRITE DMA EXT
141  35 00 d5 01 00 00 00 ec 40 f4 c0 40 00     02:55:18.631  WRITE DMA EXT
142  35 00 d5 01 00 00 00 ec 40 f3 c0 40 00     02:55:18.630  WRITE DMA EXT
143  35 00 d5 01 00 00 00 ec 40 f2 c0 40 00     02:55:18.629  WRITE DMA EXT
144  35 00 d5 01 00 00 00 ec 40 f1 c0 40 00     02:55:18.628  WRITE DMA EXT
145
146SMART Extended Self-test Log Version: 1 (1 sectors)
147Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
148# 1  Extended offline    Completed without error       00%       206         -
149# 2  Short offline       Completed without error       00%       203         -
150
151SMART Selective self-test log data structure revision number 1
152 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
153    1        0        0  Not_testing
154    2        0        0  Not_testing
155    3        0        0  Not_testing
156    4        0        0  Not_testing
157    5        0        0  Not_testing
158Selective self-test flags (0x0):
159  After scanning selected spans, do NOT read-scan remainder of disk.
160If Selective self-test is pending on power-up, resume after 0 minute delay.
161
162SCT Status Version:                  3
163SCT Version (vendor specific):       256 (0x0100)
164SCT Support Level:                   1
165Device State:                        SMART Off-line Data Collection executing in background (4)
166Current Temperature:                    52 Celsius
167Power Cycle Min/Max Temperature:     26/54 Celsius
168Lifetime    Min/Max Temperature:     21/54 Celsius
169Under/Over Temperature Limit Count:   0/0
170
171SCT Temperature History Version:     2
172Temperature Sampling Period:         1 minute
173Temperature Logging Interval:        1 minute
174Min/Max recommended Temperature:      0/60 Celsius
175Min/Max Temperature Limit:           -40/70 Celsius
176Temperature History Size (Index):    128 (22)
177
178Index    Estimated Time   Temperature Celsius
179  23    2016-10-28 11:36    51  ********************************
180 ...    ..(120 skipped).    ..  ********************************
181  16    2016-10-28 13:37    51  ********************************
182  17    2016-10-28 13:38    52  *********************************
183 ...    ..(  3 skipped).    ..  *********************************
184  21    2016-10-28 13:42    52  *********************************
185  22    2016-10-28 13:43    51  ********************************
186
187SCT Error Recovery Control:
188           Read: Disabled
189          Write: Disabled
190
191Device Statistics (GP Log 0x04)
192Page  Offset Size        Value Flags Description
1930x01  =====  =               =  ===  == General Statistics (rev 2) ==
1940x01  0x008  4              16  ---  Lifetime Power-On Resets
1950x01  0x018  6    106533213099  ---  Logical Sectors Written
1960x01  0x020  6       671077955  ---  Number of Write Commands
1970x01  0x028  6        14020936  ---  Logical Sectors Read
1980x01  0x030  6          507817  ---  Number of Read Commands
1990x01  0x038  6       744213100  ---  Date and Time TimeStamp
2000x03  =====  =               =  ===  == Rotating Media Statistics (rev 1) ==
2010x03  0x008  4             206  ---  Spindle Motor Power-on Hours
2020x03  0x010  4             206  ---  Head Flying Hours
2030x03  0x018  4              20  ---  Head Load Events
2040x03  0x020  4               0  ---  Number of Reallocated Logical Sectors
2050x03  0x028  4            1036  ---  Read Recovery Attempts
2060x03  0x030  4               0  ---  Number of Mechanical Start Failures
2070x04  =====  =               =  ===  == General Errors Statistics (rev 1) ==
2080x04  0x008  4               0  ---  Number of Reported Uncorrectable Errors
2090x04  0x010  4               0  ---  Resets Between Cmd Acceptance and Completion
2100x05  =====  =               =  ===  == Temperature Statistics (rev 1) ==
2110x05  0x008  1              52  ---  Current Temperature
2120x05  0x010  1              52  N--  Average Short Term Temperature
2130x05  0x018  1               -  N--  Average Long Term Temperature
2140x05  0x020  1              54  ---  Highest Temperature
2150x05  0x028  1              21  ---  Lowest Temperature
2160x05  0x030  1              53  N--  Highest Average Short Term Temperature
2170x05  0x038  1              24  N--  Lowest Average Short Term Temperature
2180x05  0x040  1               -  N--  Highest Average Long Term Temperature
2190x05  0x048  1               -  N--  Lowest Average Long Term Temperature
2200x05  0x050  4               0  ---  Time in Over-Temperature
2210x05  0x058  1              60  ---  Specified Maximum Operating Temperature
2220x05  0x060  4               0  ---  Time in Under-Temperature
2230x05  0x068  1               0  ---  Specified Minimum Operating Temperature
2240x06  =====  =               =  ===  == Transport Statistics (rev 1) ==
2250x06  0x008  4               0  ---  Number of Hardware Resets
2260x06  0x010  4               0  ---  Number of ASR Events
2270x06  0x018  4               1  ---  Number of Interface CRC Errors
228                                |||_ C monitored condition met
229                                ||__ D supports DSN
230                                |___ N normalized value
231
232SATA Phy Event Counters (GP Log 0x11)
233ID      Size     Value  Description
2340x0001  2            0  Command failed due to ICRC error
2350x0002  2            0  R_ERR response for data FIS
2360x0003  2            0  R_ERR response for device-to-host data FIS
2370x0004  2            0  R_ERR response for host-to-device data FIS
2380x0005  2            0  R_ERR response for non-data FIS
2390x0006  2            0  R_ERR response for device-to-host non-data FIS
2400x0007  2            0  R_ERR response for host-to-device non-data FIS
2410x0008  2            0  Device-to-host non-data FIS retries
2420x0009  2            1  Transition from drive PhyRdy to drive PhyNRdy
2430x000a  2            1  Device-to-host register FISes sent due to a COMRESET
2440x000b  2            0  CRC errors within host-to-device FIS
2450x000d  2            0  Non-CRC errors within host-to-device FIS
246