1 | smartctl 5.41 2011-06-09 r3365 [i686-w64-mingw32-2008(64)-sp1] (sf-win32-5.41-1)
|
---|
2 | Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: HUS724040ALA640
|
---|
6 | Serial Number: PAG5A4BT
|
---|
7 | Firmware Version: MFAOA8D0
|
---|
8 | User Capacity: 4,000,787,030,016 bytes [4.00 TB]
|
---|
9 | Sector Size: 512 bytes logical/physical
|
---|
10 | Device is: Not in smartctl database [for details use: -P showall]
|
---|
11 | ATA Version is: 8
|
---|
12 | ATA Standard is: ATA-8-ACS revision 4
|
---|
13 | Local Time is: Tue Sep 25 16:36:01 2012 MPST
|
---|
14 | SMART support is: Available - device has SMART capability.
|
---|
15 | SMART support is: Enabled
|
---|
16 |
|
---|
17 | === START OF READ SMART DATA SECTION ===
|
---|
18 | SMART STATUS RETURN: incomplete response, ATA output registers missing
|
---|
19 | SMART overall-health self-assessment test result: PASSED
|
---|
20 | Warning: This result is based on an Attribute check.
|
---|
21 |
|
---|
22 | General SMART Values:
|
---|
23 | Offline data collection status: (0x80) Offline data collection activity
|
---|
24 | was never started.
|
---|
25 | Auto Offline Data Collection: Enabled.
|
---|
26 | Self-test execution status: ( 0) The previous self-test routine completed
|
---|
27 | without error or no self-test has ever
|
---|
28 | been run.
|
---|
29 | Total time to complete Offline
|
---|
30 | data collection: ( 24) seconds.
|
---|
31 | Offline data collection
|
---|
32 | capabilities: (0x5b) SMART execute Offline immediate.
|
---|
33 | Auto Offline data collection on/off support.
|
---|
34 | Suspend Offline collection upon new
|
---|
35 | command.
|
---|
36 | Offline surface scan supported.
|
---|
37 | Self-test supported.
|
---|
38 | No Conveyance Self-test supported.
|
---|
39 | Selective Self-test supported.
|
---|
40 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
41 | power-saving mode.
|
---|
42 | Supports SMART auto save timer.
|
---|
43 | Error logging capability: (0x01) Error logging supported.
|
---|
44 | General Purpose Logging supported.
|
---|
45 | Short self-test routine
|
---|
46 | recommended polling time: ( 1) minutes.
|
---|
47 | Extended self-test routine
|
---|
48 | recommended polling time: ( 255) minutes.
|
---|
49 | SCT capabilities: (0x003d) SCT Status supported.
|
---|
50 | SCT Error Recovery Control supported.
|
---|
51 | SCT Feature Control supported.
|
---|
52 | SCT Data Table supported.
|
---|
53 |
|
---|
54 | SMART Attributes Data Structure revision number: 16
|
---|
55 | Vendor Specific SMART Attributes with Thresholds:
|
---|
56 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
---|
57 | 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
|
---|
58 | 2 Throughput_Performance 0x0005 100 100 054 Pre-fail Offline - 0
|
---|
59 | 3 Spin_Up_Time 0x0007 100 100 024 Pre-fail Always - 0
|
---|
60 | 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 7
|
---|
61 | 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
|
---|
62 | 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
|
---|
63 | 8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0
|
---|
64 | 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 23
|
---|
65 | 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
|
---|
66 | 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 7
|
---|
67 | 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 8
|
---|
68 | 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 8
|
---|
69 | 194 Temperature_Celsius 0x0002 157 157 000 Old_age Always - 38 (Min/Max 6/42)
|
---|
70 | 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
|
---|
71 | 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
|
---|
72 | 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
|
---|
73 | 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
|
---|
74 |
|
---|
75 | SMART Error Log Version: 1
|
---|
76 | No Errors Logged
|
---|
77 |
|
---|
78 | SMART Self-test log structure revision number 1
|
---|
79 | No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
---|
80 |
|
---|
81 |
|
---|
82 | SMART Selective self-test log data structure revision number 1
|
---|
83 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
---|
84 | 1 0 0 Not_testing
|
---|
85 | 2 0 0 Not_testing
|
---|
86 | 3 0 0 Not_testing
|
---|
87 | 4 0 0 Not_testing
|
---|
88 | 5 0 0 Not_testing
|
---|
89 | Selective self-test flags (0x0):
|
---|
90 | After scanning selected spans, do NOT read-scan remainder of disk.
|
---|
91 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
---|
92 |
|
---|