| 1 | smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.5.0-44-generic] (local build)
|
|---|
| 2 | Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|---|
| 3 |
|
|---|
| 4 | === START OF INFORMATION SECTION ===
|
|---|
| 5 | Device Model: UB88SAB8000CS1-CTC-ORC
|
|---|
| 6 | Serial Number: 11000548785
|
|---|
| 7 | LU WWN Device Id: 5 00a075 600085fb1
|
|---|
| 8 | Firmware Version: S9FM01.6
|
|---|
| 9 | User Capacity: 8,012,390,400 bytes [8.01 GB]
|
|---|
| 10 | Sector Size: 512 bytes logical/physical
|
|---|
| 11 | Rotation Rate: Solid State Device
|
|---|
| 12 | Form Factor: 2.5 inches
|
|---|
| 13 | TRIM Command: Available
|
|---|
| 14 | Device is: Not in smartctl database 7.3/5319
|
|---|
| 15 | ATA Version is: ACS-3 (minor revision not indicated)
|
|---|
| 16 | SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
|---|
| 17 | Local Time is: Thu Jul 25 09:30:33 2024 PDT
|
|---|
| 18 | SMART support is: Available - device has SMART capability.
|
|---|
| 19 | SMART support is: Enabled
|
|---|
| 20 |
|
|---|
| 21 | === START OF READ SMART DATA SECTION ===
|
|---|
| 22 | SMART overall-health self-assessment test result: PASSED
|
|---|
| 23 |
|
|---|
| 24 | General SMART Values:
|
|---|
| 25 | Offline data collection status: (0x00) Offline data collection activity
|
|---|
| 26 | was never started.
|
|---|
| 27 | Auto Offline Data Collection: Disabled.
|
|---|
| 28 | Self-test execution status: ( 0) The previous self-test routine completed
|
|---|
| 29 | without error or no self-test has ever
|
|---|
| 30 | been run.
|
|---|
| 31 | Total time to complete Offline
|
|---|
| 32 | data collection: ( 30) seconds.
|
|---|
| 33 | Offline data collection
|
|---|
| 34 | capabilities: (0x7b) SMART execute Offline immediate.
|
|---|
| 35 | Auto Offline data collection on/off support.
|
|---|
| 36 | Suspend Offline collection upon new
|
|---|
| 37 | command.
|
|---|
| 38 | Offline surface scan supported.
|
|---|
| 39 | Self-test supported.
|
|---|
| 40 | Conveyance Self-test supported.
|
|---|
| 41 | Selective Self-test supported.
|
|---|
| 42 | SMART capabilities: (0x0003) Saves SMART data before entering
|
|---|
| 43 | power-saving mode.
|
|---|
| 44 | Supports SMART auto save timer.
|
|---|
| 45 | Error logging capability: (0x01) Error logging supported.
|
|---|
| 46 | General Purpose Logging supported.
|
|---|
| 47 | Short self-test routine
|
|---|
| 48 | recommended polling time: ( 1) minutes.
|
|---|
| 49 | Extended self-test routine
|
|---|
| 50 | recommended polling time: ( 2) minutes.
|
|---|
| 51 | Conveyance self-test routine
|
|---|
| 52 | recommended polling time: ( 2) minutes.
|
|---|
| 53 |
|
|---|
| 54 | SMART Attributes Data Structure revision number: 16
|
|---|
| 55 | Vendor Specific SMART Attributes with Thresholds:
|
|---|
| 56 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|---|
| 57 | 1 Raw_Read_Error_Rate 0x000a 099 099 000 Old_age Always - 170945
|
|---|
| 58 | 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 5153
|
|---|
| 59 | 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 66
|
|---|
| 60 | 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0
|
|---|
| 61 | 170 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 43
|
|---|
| 62 | 173 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 87884678
|
|---|
| 63 | 177 Wear_Leveling_Count 0x0000 100 100 000 Old_age Offline - 0
|
|---|
| 64 | 181 Program_Fail_Cnt_Total 0x0012 100 100 000 Old_age Always - 0
|
|---|
| 65 | 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 13
|
|---|
| 66 | 218 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 0
|
|---|
| 67 | 231 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 99
|
|---|
| 68 | 233 Media_Wearout_Indicator 0x0013 100 100 000 Pre-fail Always - 7877
|
|---|
| 69 | 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 620
|
|---|
| 70 | 242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 59622
|
|---|
| 71 | 246 Unknown_Attribute 0x0000 100 100 000 Old_age Offline - 3750667
|
|---|
| 72 |
|
|---|
| 73 | SMART Error Log Version: 1
|
|---|
| 74 | No Errors Logged
|
|---|
| 75 |
|
|---|
| 76 | SMART Self-test log structure revision number 1
|
|---|
| 77 | No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|---|
| 78 |
|
|---|
| 79 | SMART Selective self-test log data structure revision number 0
|
|---|
| 80 | Note: revision number not 1 implies that no selective self-test has ever been run
|
|---|
| 81 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|---|
| 82 | 1 0 0 Not_testing
|
|---|
| 83 | 2 0 0 Not_testing
|
|---|
| 84 | 3 0 0 Not_testing
|
|---|
| 85 | 4 0 0 Not_testing
|
|---|
| 86 | 5 0 0 Not_testing
|
|---|
| 87 | Selective self-test flags (0x0):
|
|---|
| 88 | After scanning selected spans, do NOT read-scan remainder of disk.
|
|---|
| 89 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|---|
| 90 |
|
|---|