1 | smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.4.9-100.fc37.x86_64] (local build)
|
---|
2 | Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Model Number: Samsung SSD 970 EVO Plus 250GB
|
---|
6 | Serial Number: S4EUNX0R533480T
|
---|
7 | Firmware Version: 2B2QEXM7
|
---|
8 | PCI Vendor/Subsystem ID: 0x144d
|
---|
9 | IEEE OUI Identifier: 0x002538
|
---|
10 | Total NVM Capacity: 250,059,350,016 [250 GB]
|
---|
11 | Unallocated NVM Capacity: 0
|
---|
12 | Controller ID: 4
|
---|
13 | NVMe Version: 1.3
|
---|
14 | Number of Namespaces: 1
|
---|
15 | Namespace 1 Size/Capacity: 250,059,350,016 [250 GB]
|
---|
16 | Namespace 1 Utilization: 12,304,850,944 [12.3 GB]
|
---|
17 | Namespace 1 Formatted LBA Size: 512
|
---|
18 | Namespace 1 IEEE EUI-64: 002538 5511b13e89
|
---|
19 | Local Time is: Sun Oct 1 17:44:24 2023 +08
|
---|
20 | Firmware Updates (0x16): 3 Slots, no Reset required
|
---|
21 | Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
---|
22 | Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
---|
23 | Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
---|
24 | Maximum Data Transfer Size: 512 Pages
|
---|
25 | Warning Comp. Temp. Threshold: 85 Celsius
|
---|
26 | Critical Comp. Temp. Threshold: 85 Celsius
|
---|
27 |
|
---|
28 | Supported Power States
|
---|
29 | St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
---|
30 | 0 + 7.80W - - 0 0 0 0 0 0
|
---|
31 | 1 + 6.00W - - 1 1 1 1 0 0
|
---|
32 | 2 + 3.40W - - 2 2 2 2 0 0
|
---|
33 | 3 - 0.0700W - - 3 3 3 3 210 1200
|
---|
34 | 4 - 0.0100W - - 4 4 4 4 2000 8000
|
---|
35 |
|
---|
36 | Supported LBA Sizes (NSID 0x1)
|
---|
37 | Id Fmt Data Metadt Rel_Perf
|
---|
38 | 0 + 512 0 0
|
---|
39 |
|
---|
40 | === START OF SMART DATA SECTION ===
|
---|
41 | SMART overall-health self-assessment test result: PASSED
|
---|
42 |
|
---|
43 | SMART/Health Information (NVMe Log 0x02)
|
---|
44 | Critical Warning: 0x00
|
---|
45 | Temperature: 47 Celsius
|
---|
46 | Available Spare: 100%
|
---|
47 | Available Spare Threshold: 10%
|
---|
48 | Percentage Used: 0%
|
---|
49 | Data Units Read: 496,236 [254 GB]
|
---|
50 | Data Units Written: 124,777 [63.8 GB]
|
---|
51 | Host Read Commands: 5,142,195
|
---|
52 | Host Write Commands: 889,826
|
---|
53 | Controller Busy Time: 18
|
---|
54 | Power Cycles: 215
|
---|
55 | Power On Hours: 300
|
---|
56 | Unsafe Shutdowns: 3
|
---|
57 | Media and Data Integrity Errors: 0
|
---|
58 | Error Information Log Entries: 265
|
---|
59 | Warning Comp. Temperature Time: 0
|
---|
60 | Critical Comp. Temperature Time: 0
|
---|
61 | Temperature Sensor 1: 47 Celsius
|
---|
62 | Temperature Sensor 2: 45 Celsius
|
---|
63 |
|
---|
64 | Error Information (NVMe Log 0x01, 16 of 64 entries)
|
---|
65 | Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
|
---|
66 | 0 265 0 0x0008 0x4004 - 0 0 - Invalid Field in Command
|
---|
67 |
|
---|
68 | Self-test Log (NVMe Log 0x06)
|
---|
69 | Self-test status: No self-test in progress
|
---|
70 | Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
---|
71 | 0 Short Completed without error 300 - - - - -
|
---|
72 | 1 Short Completed without error 0 - - - - -
|
---|
73 |
|
---|