Ticket #1742: smartctl-SEAGATE-ST12000NM000J-2TY103.txt

File smartctl-SEAGATE-ST12000NM000J-2TY103.txt, 18.6 KB (added by Adrian Sevcenco, 15 months ago)

Seagate Exos X18 ST12000NM000J-2TY103

Line 
1smartctl 7.0 2018-12-30 r4883 [x86_64-linux-6.4.11-1.el7.elrepo.x86_64] (local build)
2Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: ST12000NM000J-2TY103
6Firmware Version: SN02
7User Capacity: 12,000,138,625,024 bytes [12.0 TB]
8Sector Sizes: 512 bytes logical, 4096 bytes physical
9Rotation Rate: 7200 rpm
10Form Factor: 3.5 inches
11Device is: Not in smartctl database [for details use: -P showall]
12ATA Version is: ACS-4 (minor revision not indicated)
13SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
14Local Time is: Fri Sep 1 19:18:17 2023 EEST
15SMART support is: Available - device has SMART capability.
16SMART support is: Enabled
17AAM feature is: Unavailable
18APM feature is: Unavailable
19Rd look-ahead is: Enabled
20Write cache is: Enabled
21DSN feature is: Disabled
22ATA Security is: Disabled, NOT FROZEN [SEC1]
23Write SCT (Get) Feature Control Command failed: scsi error badly formed scsi parameters
24Wt Cache Reorder: Unknown (SCT Feature Control command failed)
25
26=== START OF READ SMART DATA SECTION ===
27SMART overall-health self-assessment test result: PASSED
28
29General SMART Values:
30Offline data collection status: (0x82) Offline data collection activity
31 was completed without error.
32 Auto Offline Data Collection: Enabled.
33Self-test execution status: ( 0) The previous self-test routine completed
34 without error or no self-test has ever
35 been run.
36Total time to complete Offline
37data collection: ( 567) seconds.
38Offline data collection
39capabilities: (0x7b) SMART execute Offline immediate.
40 Auto Offline data collection on/off support.
41 Suspend Offline collection upon new
42 command.
43 Offline surface scan supported.
44 Self-test supported.
45 Conveyance Self-test supported.
46 Selective Self-test supported.
47SMART capabilities: (0x0003) Saves SMART data before entering
48 power-saving mode.
49 Supports SMART auto save timer.
50Error logging capability: (0x01) Error logging supported.
51 General Purpose Logging supported.
52Short self-test routine
53recommended polling time: ( 1) minutes.
54Extended self-test routine
55recommended polling time: (1058) minutes.
56Conveyance self-test routine
57recommended polling time: ( 2) minutes.
58SCT capabilities: (0x70bd) SCT Status supported.
59 SCT Error Recovery Control supported.
60 SCT Feature Control supported.
61 SCT Data Table supported.
62
63SMART Attributes Data Structure revision number: 10
64Vendor Specific SMART Attributes with Thresholds:
65ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
66 1 Raw_Read_Error_Rate POSR-- 081 064 044 - 125357635
67 3 Spin_Up_Time PO---- 094 094 000 - 0
68 4 Start_Stop_Count -O--CK 100 100 020 - 6
69 5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
70 7 Seek_Error_Rate POSR-- 087 060 045 - 486722692
71 9 Power_On_Hours -O--CK 093 093 000 - 6732
72 10 Spin_Retry_Count PO--C- 100 100 097 - 0
73 12 Power_Cycle_Count -O--CK 100 100 020 - 6
74 18 Unknown_Attribute PO-R-- 100 100 050 - 0
75187 Reported_Uncorrect -O--CK 100 100 000 - 0
76188 Command_Timeout -O--CK 100 100 000 - 0
77190 Airflow_Temperature_Cel -O---K 071 052 000 - 29 (Min/Max 28/37)
78192 Power-Off_Retract_Count -O--CK 100 100 000 - 1
79193 Load_Cycle_Count -O--CK 094 094 000 - 13865
80194 Temperature_Celsius -O---K 029 048 000 - 29 (0 26 0 0 0)
81197 Current_Pending_Sector -O--C- 100 100 000 - 0
82198 Offline_Uncorrectable ----C- 100 100 000 - 0
83199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
84200 Multi_Zone_Error_Rate PO---K 100 100 001 - 0
85240 Head_Flying_Hours ------ 100 253 000 - 1952 (191 94 0)
86241 Total_LBAs_Written ------ 100 253 000 - 65433005000
87242 Total_LBAs_Read ------ 100 253 000 - 8859028553953
88 ||||||_ K auto-keep
89 |||||__ C event count
90 ||||___ R error rate
91 |||____ S speed/performance
92 ||_____ O updated online
93 |______ P prefailure warning
94
95General Purpose Log Directory Version 1
96SMART Log Directory Version 1 [multi-sector log support]
97Address Access R/W Size Description
980x00 GPL,SL R/O 1 Log Directory
990x01 SL R/O 1 Summary SMART error log
1000x02 SL R/O 5 Comprehensive SMART error log
1010x03 GPL R/O 5 Ext. Comprehensive SMART error log
1020x04 GPL R/O 256 Device Statistics log
1030x04 SL R/O 8 Device Statistics log
1040x06 SL R/O 1 SMART self-test log
1050x07 GPL R/O 1 Extended self-test log
1060x08 GPL R/O 2 Power Conditions log
1070x09 SL R/W 1 Selective self-test log
1080x0a GPL R/W 8 Device Statistics Notification
1090x0c GPL R/O 2048 Pending Defects log
1100x10 GPL R/O 1 NCQ Command Error log
1110x11 GPL R/O 1 SATA Phy Event Counters log
1120x13 GPL R/O 1 SATA NCQ Send and Receive log
1130x21 GPL R/O 1 Write stream error log
1140x22 GPL R/O 1 Read stream error log
1150x24 GPL R/O 768 Current Device Internal Status Data log
1160x2f GPL - 1 Set Sector Configuration
1170x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
1180x80-0x9f GPL,SL R/W 16 Host vendor specific log
1190xa1 GPL,SL VS 160 Device vendor specific log
1200xa2 GPL VS 16320 Device vendor specific log
1210xa4 GPL,SL VS 160 Device vendor specific log
1220xa6 GPL VS 192 Device vendor specific log
1230xa8-0xa9 GPL,SL VS 136 Device vendor specific log
1240xab GPL VS 1 Device vendor specific log
1250xad GPL VS 16 Device vendor specific log
1260xb1 GPL,SL VS 160 Device vendor specific log
1270xb6 GPL VS 1920 Device vendor specific log
1280xbe-0xbf GPL VS 65535 Device vendor specific log
1290xc1 GPL,SL VS 8 Device vendor specific log
1300xc3 GPL,SL VS 24 Device vendor specific log
1310xc6 GPL VS 5184 Device vendor specific log
1320xc7 GPL,SL VS 8 Device vendor specific log
1330xc9 GPL,SL VS 8 Device vendor specific log
1340xca GPL,SL VS 16 Device vendor specific log
1350xcd GPL,SL VS 1 Device vendor specific log
1360xce GPL VS 1 Device vendor specific log
1370xcf GPL VS 512 Device vendor specific log
1380xd1 GPL VS 656 Device vendor specific log
1390xd2 GPL VS 10256 Device vendor specific log
1400xd4 GPL VS 2048 Device vendor specific log
1410xda GPL,SL VS 1 Device vendor specific log
1420xe0 GPL,SL R/W 1 SCT Command/Status
1430xe1 GPL,SL R/W 1 SCT Data Transfer
144
145SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
146No Errors Logged
147
148SMART Extended Self-test Log Version: 1 (1 sectors)
149Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
150# 1 Short offline Completed without error 00% 6666 -
151# 2 Short offline Completed without error 00% 6594 -
152# 3 Short offline Completed without error 00% 6522 -
153# 4 Short offline Completed without error 00% 6450 -
154# 5 Short offline Completed without error 00% 6379 -
155# 6 Extended offline Completed without error 00% 6323 -
156# 7 Short offline Completed without error 00% 6259 -
157# 8 Short offline Completed without error 00% 6187 -
158# 9 Short offline Completed without error 00% 6115 -
159#10 Short offline Completed without error 00% 6043 -
160#11 Short offline Completed without error 00% 5923 -
161#12 Short offline Completed without error 00% 5851 -
162#13 Short offline Completed without error 00% 5779 -
163#14 Short offline Completed without error 00% 5707 -
164#15 Short offline Completed without error 00% 5635 -
165#16 Extended offline Completed without error 00% 5619 -
166#17 Short offline Completed without error 00% 5515 -
167#18 Short offline Completed without error 00% 5443 -
168#19 Short offline Completed without error 00% 5371 -
169
170SMART Selective self-test log data structure revision number 1
171 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
172 1 0 0 Not_testing
173 2 0 0 Not_testing
174 3 0 0 Not_testing
175 4 0 0 Not_testing
176 5 0 0 Not_testing
177Selective self-test flags (0x0):
178 After scanning selected spans, do NOT read-scan remainder of disk.
179If Selective self-test is pending on power-up, resume after 0 minute delay.
180
181SCT Status Version: 3
182SCT Version (vendor specific): 522 (0x020a)
183Device State: Active (0)
184Current Temperature: 29 Celsius
185Power Cycle Min/Max Temperature: 28/37 Celsius
186Lifetime Min/Max Temperature: 25/55 Celsius
187Under/Over Temperature Limit Count: 0/0
188SMART Status: 0xc24f (PASSED)
189Vendor specific:
19000 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
19100 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00
192
193SCT Temperature History Version: 2
194Temperature Sampling Period: 4 minutes
195Temperature Logging Interval: 59 minutes
196Min/Max recommended Temperature: 10/40 Celsius
197Min/Max Temperature Limit: 5/60 Celsius
198Temperature History Size (Index): 128 (52)
199
200Index Estimated Time Temperature Celsius
201 53 2023-08-27 13:34 31 ************
202 ... ..( 2 skipped). .. ************
203 56 2023-08-27 16:31 31 ************
204 57 2023-08-27 17:30 30 ***********
205 58 2023-08-27 18:29 30 ***********
206 59 2023-08-27 19:28 31 ************
207 60 2023-08-27 20:27 30 ***********
208 61 2023-08-27 21:26 30 ***********
209 62 2023-08-27 22:25 30 ***********
210 63 2023-08-27 23:24 29 **********
211 64 2023-08-28 00:23 30 ***********
212 65 2023-08-28 01:22 29 **********
213 66 2023-08-28 02:21 30 ***********
214 67 2023-08-28 03:20 30 ***********
215 68 2023-08-28 04:19 29 **********
216 69 2023-08-28 05:18 31 ************
217 70 2023-08-28 06:17 30 ***********
218 71 2023-08-28 07:16 30 ***********
219 72 2023-08-28 08:15 30 ***********
220 73 2023-08-28 09:14 31 ************
221 74 2023-08-28 10:13 31 ************
222 75 2023-08-28 11:12 30 ***********
223 76 2023-08-28 12:11 30 ***********
224 77 2023-08-28 13:10 30 ***********
225 78 2023-08-28 14:09 31 ************
226 79 2023-08-28 15:08 31 ************
227 80 2023-08-28 16:07 29 **********
228 81 2023-08-28 17:06 30 ***********
229 82 2023-08-28 18:05 30 ***********
230 83 2023-08-28 19:04 31 ************
231 84 2023-08-28 20:03 29 **********
232 85 2023-08-28 21:02 30 ***********
233 86 2023-08-28 22:01 29 **********
234 ... ..( 4 skipped). .. **********
235 91 2023-08-29 02:56 29 **********
236 92 2023-08-29 03:55 31 ************
237 93 2023-08-29 04:54 29 **********
238 94 2023-08-29 05:53 29 **********
239 95 2023-08-29 06:52 30 ***********
240 96 2023-08-29 07:51 29 **********
241 97 2023-08-29 08:50 29 **********
242 98 2023-08-29 09:49 29 **********
243 99 2023-08-29 10:48 31 ************
244 100 2023-08-29 11:47 30 ***********
245 101 2023-08-29 12:46 29 **********
246 102 2023-08-29 13:45 30 ***********
247 103 2023-08-29 14:44 29 **********
248 104 2023-08-29 15:43 30 ***********
249 105 2023-08-29 16:42 32 *************
250 106 2023-08-29 17:41 30 ***********
251 107 2023-08-29 18:40 30 ***********
252 108 2023-08-29 19:39 29 **********
253 ... ..( 2 skipped). .. **********
254 111 2023-08-29 22:36 29 **********
255 112 2023-08-29 23:35 31 ************
256 113 2023-08-30 00:34 32 *************
257 114 2023-08-30 01:33 30 ***********
258 115 2023-08-30 02:32 31 ************
259 116 2023-08-30 03:31 31 ************
260 117 2023-08-30 04:30 30 ***********
261 118 2023-08-30 05:29 30 ***********
262 119 2023-08-30 06:28 30 ***********
263 120 2023-08-30 07:27 29 **********
264 121 2023-08-30 08:26 29 **********
265 122 2023-08-30 09:25 31 ************
266 123 2023-08-30 10:24 31 ************
267 124 2023-08-30 11:23 30 ***********
268 125 2023-08-30 12:22 30 ***********
269 126 2023-08-30 13:21 30 ***********
270 127 2023-08-30 14:20 31 ************
271 0 2023-08-30 15:19 30 ***********
272 1 2023-08-30 16:18 31 ************
273 2 2023-08-30 17:17 29 **********
274 ... ..( 2 skipped). .. **********
275 5 2023-08-30 20:14 29 **********
276 6 2023-08-30 21:13 30 ***********
277 7 2023-08-30 22:12 29 **********
278 ... ..( 2 skipped). .. **********
279 10 2023-08-31 01:09 29 **********
280 11 2023-08-31 02:08 31 ************
281 12 2023-08-31 03:07 29 **********
282 13 2023-08-31 04:06 30 ***********
283 14 2023-08-31 05:05 31 ************
284 15 2023-08-31 06:04 29 **********
285 16 2023-08-31 07:03 31 ************
286 17 2023-08-31 08:02 32 *************
287 18 2023-08-31 09:01 30 ***********
288 19 2023-08-31 10:00 31 ************
289 20 2023-08-31 10:59 32 *************
290 21 2023-08-31 11:58 30 ***********
291 22 2023-08-31 12:57 30 ***********
292 23 2023-08-31 13:56 30 ***********
293 24 2023-08-31 14:55 31 ************
294 25 2023-08-31 15:54 29 **********
295 26 2023-08-31 16:53 29 **********
296 27 2023-08-31 17:52 29 **********
297 28 2023-08-31 18:51 28 *********
298 29 2023-08-31 19:50 29 **********
299 30 2023-08-31 20:49 29 **********
300 31 2023-08-31 21:48 29 **********
301 32 2023-08-31 22:47 28 *********
302 33 2023-08-31 23:46 28 *********
303 34 2023-09-01 00:45 33 **************
304 ... ..( 8 skipped). .. **************
305 43 2023-09-01 09:36 33 **************
306 44 2023-09-01 10:35 34 ***************
307 45 2023-09-01 11:34 34 ***************
308 46 2023-09-01 12:33 33 **************
309 47 2023-09-01 13:32 33 **************
310 48 2023-09-01 14:31 34 ***************
311 49 2023-09-01 15:30 33 **************
312 50 2023-09-01 16:29 33 **************
313 51 2023-09-01 17:28 33 **************
314 52 2023-09-01 18:27 29 **********
315
316SCT Error Recovery Control:
317 Read: 100 (10.0 seconds)
318 Write: 100 (10.0 seconds)
319
320Device Statistics (GP Log 0x04)
321Page Offset Size Value Flags Description
3220x01 ===== = = === == General Statistics (rev 1) ==
3230x01 0x008 4 6 --- Lifetime Power-On Resets
3240x01 0x010 4 6732 --- Power-on Hours
3250x01 0x018 6 65433005000 --- Logical Sectors Written
3260x01 0x020 6 125851114 --- Number of Write Commands
3270x01 0x028 6 8859028553953 --- Logical Sectors Read
3280x01 0x030 6 1302310044 --- Number of Read Commands
3290x01 0x038 6 - --- Date and Time TimeStamp
3300x03 ===== = = === == Rotating Media Statistics (rev 1) ==
3310x03 0x008 4 6732 --- Spindle Motor Power-on Hours
3320x03 0x010 4 2432 --- Head Flying Hours
3330x03 0x018 4 13865 --- Head Load Events
3340x03 0x020 4 0 --- Number of Reallocated Logical Sectors
3350x03 0x028 4 0 --- Read Recovery Attempts
3360x03 0x030 4 0 --- Number of Mechanical Start Failures
3370x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
3380x03 0x040 4 1 --- Number of High Priority Unload Events
3390x04 ===== = = === == General Errors Statistics (rev 1) ==
3400x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
3410x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
3420x04 0x018 4 0 -D- Physical Element Status Changed
3430x05 ===== = = === == Temperature Statistics (rev 1) ==
3440x05 0x008 1 29 --- Current Temperature
3450x05 0x010 1 31 --- Average Short Term Temperature
3460x05 0x018 1 29 --- Average Long Term Temperature
3470x05 0x020 1 48 --- Highest Temperature
3480x05 0x028 1 27 --- Lowest Temperature
3490x05 0x030 1 37 --- Highest Average Short Term Temperature
3500x05 0x038 1 29 --- Lowest Average Short Term Temperature
3510x05 0x040 1 34 --- Highest Average Long Term Temperature
3520x05 0x048 1 29 --- Lowest Average Long Term Temperature
3530x05 0x050 4 0 --- Time in Over-Temperature
3540x05 0x058 1 60 --- Specified Maximum Operating Temperature
3550x05 0x060 4 0 --- Time in Under-Temperature
3560x05 0x068 1 5 --- Specified Minimum Operating Temperature
3570x06 ===== = = === == Transport Statistics (rev 1) ==
3580x06 0x008 4 55 --- Number of Hardware Resets
3590x06 0x010 4 14 --- Number of ASR Events
3600x06 0x018 4 0 --- Number of Interface CRC Errors
3610xff ===== = = === == Vendor Specific Statistics (rev 1) ==
3620xff 0x008 7 0 --- Vendor Specific
3630xff 0x010 7 0 --- Vendor Specific
3640xff 0x018 7 0 --- Vendor Specific
365 |||_ C monitored condition met
366 ||__ D supports DSN
367 |___ N normalized value
368
369Pending Defects log (GP Log 0x0c)
370No Defects Logged
371
372SATA Phy Event Counters (GP Log 0x11)
373ID Size Value Description
3740x000a 2 19 Device-to-host register FISes sent due to a COMRESET
3750x0001 2 0 Command failed due to ICRC error
3760x0003 2 0 R_ERR response for device-to-host data FIS
3770x0004 2 0 R_ERR response for host-to-device data FIS
3780x0006 2 0 R_ERR response for device-to-host non-data FIS
3790x0007 2 0 R_ERR response for host-to-device non-data FIS
380