| 1 | smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.2.12-300.fc38.x86_64] (local build)
|
|---|
| 2 | Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
|---|
| 3 |
|
|---|
| 4 | === START OF INFORMATION SECTION ===
|
|---|
| 5 | Model Number: WDC PC SN730 SDBQNTY-1T00-1001
|
|---|
| 6 | Firmware Version: 11170101
|
|---|
| 7 | PCI Vendor/Subsystem ID: 0x15b7
|
|---|
| 8 | IEEE OUI Identifier: 0x001b44
|
|---|
| 9 | Total NVM Capacity: 1 024 209 543 168 [1,02 TB]
|
|---|
| 10 | Unallocated NVM Capacity: 0
|
|---|
| 11 | Controller ID: 8215
|
|---|
| 12 | NVMe Version: 1.3
|
|---|
| 13 | Number of Namespaces: 1
|
|---|
| 14 | Namespace 1 Size/Capacity: 1 024 209 543 168 [1,02 TB]
|
|---|
| 15 | Namespace 1 Formatted LBA Size: 512
|
|---|
| 16 | Namespace 1 IEEE EUI-64: 001b44 8b4966ff0b
|
|---|
| 17 | Local Time is: Wed Apr 26 10:36:00 2023 PDT
|
|---|
| 18 | Firmware Updates (0x14): 2 Slots, no Reset required
|
|---|
| 19 | Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
|---|
| 20 | Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
|---|
| 21 | Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
|
|---|
| 22 | Maximum Data Transfer Size: 128 Pages
|
|---|
| 23 | Warning Comp. Temp. Threshold: 84 Celsius
|
|---|
| 24 | Critical Comp. Temp. Threshold: 88 Celsius
|
|---|
| 25 | Namespace 1 Features (0x02): NA_Fields
|
|---|
| 26 |
|
|---|
| 27 | Supported Power States
|
|---|
| 28 | St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
|---|
| 29 | 0 + 6.00W - - 0 0 0 0 0 0
|
|---|
| 30 | 1 + 3.50W - - 1 1 1 1 0 0
|
|---|
| 31 | 2 + 3.00W - - 2 2 2 2 0 0
|
|---|
| 32 | 3 - 0.1000W - - 3 3 3 3 4000 10000
|
|---|
| 33 | 4 - 0.0035W - - 4 4 4 4 4000 40000
|
|---|
| 34 |
|
|---|
| 35 | Supported LBA Sizes (NSID 0x1)
|
|---|
| 36 | Id Fmt Data Metadt Rel_Perf
|
|---|
| 37 | 0 + 512 0 2
|
|---|
| 38 | 1 - 4096 0 1
|
|---|
| 39 |
|
|---|
| 40 | === START OF SMART DATA SECTION ===
|
|---|
| 41 | SMART overall-health self-assessment test result: PASSED
|
|---|
| 42 |
|
|---|
| 43 | SMART/Health Information (NVMe Log 0x02)
|
|---|
| 44 | Critical Warning: 0x00
|
|---|
| 45 | Temperature: 37 Celsius
|
|---|
| 46 | Available Spare: 100%
|
|---|
| 47 | Available Spare Threshold: 10%
|
|---|
| 48 | Percentage Used: 0%
|
|---|
| 49 | Data Units Read: 20 172 905 [10,3 TB]
|
|---|
| 50 | Data Units Written: 19 309 766 [9,88 TB]
|
|---|
| 51 | Host Read Commands: 191 501 449
|
|---|
| 52 | Host Write Commands: 203 413 442
|
|---|
| 53 | Controller Busy Time: 425
|
|---|
| 54 | Power Cycles: 1 502
|
|---|
| 55 | Power On Hours: 311
|
|---|
| 56 | Unsafe Shutdowns: 99
|
|---|
| 57 | Media and Data Integrity Errors: 0
|
|---|
| 58 | Error Information Log Entries: 0
|
|---|
| 59 | Warning Comp. Temperature Time: 0
|
|---|
| 60 | Critical Comp. Temperature Time: 0
|
|---|
| 61 |
|
|---|
| 62 | Error Information (NVMe Log 0x01, 16 of 256 entries)
|
|---|
| 63 | No Errors Logged
|
|---|
| 64 |
|
|---|