1 | smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.104-1-pve] (local build)
|
---|
2 | Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: WDC WD20EFZX-68AWUN0
|
---|
6 | Firmware Version: 81.00B81
|
---|
7 | User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
---|
8 | Sector Sizes: 512 bytes logical, 4096 bytes physical
|
---|
9 | Rotation Rate: 5400 rpm
|
---|
10 | Form Factor: 3.5 inches
|
---|
11 | Device is: Not in smartctl database [for details use: -P showall]
|
---|
12 | ATA Version is: ACS-3 T13/2161-D revision 5
|
---|
13 | SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
---|
14 | Local Time is: Wed Apr 5 18:46:16 2023 -03
|
---|
15 | SMART support is: Available - device has SMART capability.
|
---|
16 | SMART support is: Enabled
|
---|
17 | AAM feature is: Unavailable
|
---|
18 | APM feature is: Unavailable
|
---|
19 | Rd look-ahead is: Enabled
|
---|
20 | Write cache is: Enabled
|
---|
21 | DSN feature is: Unavailable
|
---|
22 | ATA Security is: Disabled, frozen [SEC2]
|
---|
23 | Wt Cache Reorder: Enabled
|
---|
24 |
|
---|
25 | === START OF READ SMART DATA SECTION ===
|
---|
26 | SMART overall-health self-assessment test result: PASSED
|
---|
27 |
|
---|
28 | General SMART Values:
|
---|
29 | Offline data collection status: (0x00) Offline data collection activity
|
---|
30 | was never started.
|
---|
31 | Auto Offline Data Collection: Disabled.
|
---|
32 | Self-test execution status: ( 0) The previous self-test routine completed
|
---|
33 | without error or no self-test has ever
|
---|
34 | been run.
|
---|
35 | Total time to complete Offline
|
---|
36 | data collection: (23520) seconds.
|
---|
37 | Offline data collection
|
---|
38 | capabilities: (0x11) SMART execute Offline immediate.
|
---|
39 | No Auto Offline data collection support.
|
---|
40 | Suspend Offline collection upon new
|
---|
41 | command.
|
---|
42 | No Offline surface scan supported.
|
---|
43 | Self-test supported.
|
---|
44 | No Conveyance Self-test supported.
|
---|
45 | No Selective Self-test supported.
|
---|
46 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
47 | power-saving mode.
|
---|
48 | Supports SMART auto save timer.
|
---|
49 | Error logging capability: (0x01) Error logging supported.
|
---|
50 | General Purpose Logging supported.
|
---|
51 | Short self-test routine
|
---|
52 | recommended polling time: ( 2) minutes.
|
---|
53 | Extended self-test routine
|
---|
54 | recommended polling time: ( 252) minutes.
|
---|
55 | SCT capabilities: (0x303d) SCT Status supported.
|
---|
56 | SCT Error Recovery Control supported.
|
---|
57 | SCT Feature Control supported.
|
---|
58 | SCT Data Table supported.
|
---|
59 |
|
---|
60 | SMART Attributes Data Structure revision number: 16
|
---|
61 | Vendor Specific SMART Attributes with Thresholds:
|
---|
62 | ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
---|
63 | 1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
---|
64 | 3 Spin_Up_Time POS--K 201 201 021 - 2933
|
---|
65 | 4 Start_Stop_Count -O--CK 100 100 000 - 37
|
---|
66 | 5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
---|
67 | 7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
---|
68 | 9 Power_On_Hours -O--CK 100 100 000 - 24
|
---|
69 | 10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
---|
70 | 11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
---|
71 | 12 Power_Cycle_Count -O--CK 100 100 000 - 36
|
---|
72 | 192 Power-Off_Retract_Count -O--CK 200 200 000 - 17
|
---|
73 | 193 Load_Cycle_Count -O--CK 200 200 000 - 19
|
---|
74 | 194 Temperature_Celsius -O---K 115 108 000 - 32
|
---|
75 | 196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
---|
76 | 197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
---|
77 | 198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
---|
78 | 199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
---|
79 | 200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
---|
80 | ||||||_ K auto-keep
|
---|
81 | |||||__ C event count
|
---|
82 | ||||___ R error rate
|
---|
83 | |||____ S speed/performance
|
---|
84 | ||_____ O updated online
|
---|
85 | |______ P prefailure warning
|
---|
86 |
|
---|
87 | General Purpose Log Directory Version 1
|
---|
88 | SMART Log Directory Version 1 [multi-sector log support]
|
---|
89 | Address Access R/W Size Description
|
---|
90 | 0x00 GPL,SL R/O 1 Log Directory
|
---|
91 | 0x01 SL R/O 1 Summary SMART error log
|
---|
92 | 0x02 SL R/O 5 Comprehensive SMART error log
|
---|
93 | 0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
---|
94 | 0x04 GPL,SL R/O 8 Device Statistics log
|
---|
95 | 0x06 SL R/O 1 SMART self-test log
|
---|
96 | 0x07 GPL R/O 1 Extended self-test log
|
---|
97 | 0x09 SL R/W 1 Selective self-test log
|
---|
98 | 0x10 GPL R/O 1 NCQ Command Error log
|
---|
99 | 0x11 GPL R/O 1 SATA Phy Event Counters log
|
---|
100 | 0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
---|
101 | 0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
---|
102 | 0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
---|
103 | 0xa8-0xb6 GPL,SL VS 1 Device vendor specific log
|
---|
104 | 0xb7 GPL,SL VS 78 Device vendor specific log
|
---|
105 | 0xbd GPL,SL VS 1 Device vendor specific log
|
---|
106 | 0xc0 GPL,SL VS 1 Device vendor specific log
|
---|
107 | 0xc1 GPL VS 93 Device vendor specific log
|
---|
108 | 0xe0 GPL,SL R/W 1 SCT Command/Status
|
---|
109 | 0xe1 GPL,SL R/W 1 SCT Data Transfer
|
---|
110 |
|
---|
111 | SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
---|
112 | No Errors Logged
|
---|
113 |
|
---|
114 | SMART Extended Self-test Log Version: 1 (1 sectors)
|
---|
115 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
---|
116 | # 1 Short offline Completed without error 00% 24 -
|
---|
117 |
|
---|
118 | Selective Self-tests/Logging not supported
|
---|
119 |
|
---|
120 | SCT Status Version: 3
|
---|
121 | SCT Version (vendor specific): 258 (0x0102)
|
---|
122 | Device State: Active (0)
|
---|
123 | Current Temperature: 32 Celsius
|
---|
124 | Power Cycle Min/Max Temperature: 22/32 Celsius
|
---|
125 | Lifetime Min/Max Temperature: 22/39 Celsius
|
---|
126 | Under/Over Temperature Limit Count: 0/0
|
---|
127 | Vendor specific:
|
---|
128 | 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
---|
129 | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
---|
130 |
|
---|
131 | SCT Temperature History Version: 2
|
---|
132 | Temperature Sampling Period: 1 minute
|
---|
133 | Temperature Logging Interval: 1 minute
|
---|
134 | Min/Max recommended Temperature: 0/65 Celsius
|
---|
135 | Min/Max Temperature Limit: -41/85 Celsius
|
---|
136 | Temperature History Size (Index): 478 (75)
|
---|
137 |
|
---|
138 | Index Estimated Time Temperature Celsius
|
---|
139 | 76 2023-04-05 10:49 30 ***********
|
---|
140 | ... ..(340 skipped). .. ***********
|
---|
141 | 417 2023-04-05 16:30 30 ***********
|
---|
142 | 418 2023-04-05 16:31 31 ************
|
---|
143 | ... ..( 67 skipped). .. ************
|
---|
144 | 8 2023-04-05 17:39 31 ************
|
---|
145 | 9 2023-04-05 17:40 32 *************
|
---|
146 | ... ..( 3 skipped). .. *************
|
---|
147 | 13 2023-04-05 17:44 32 *************
|
---|
148 | 14 2023-04-05 17:45 31 ************
|
---|
149 | ... ..( 38 skipped). .. ************
|
---|
150 | 53 2023-04-05 18:24 31 ************
|
---|
151 | 54 2023-04-05 18:25 32 *************
|
---|
152 | ... ..( 20 skipped). .. *************
|
---|
153 | 75 2023-04-05 18:46 32 *************
|
---|
154 |
|
---|
155 | SCT Error Recovery Control:
|
---|
156 | Read: 70 (7.0 seconds)
|
---|
157 | Write: 70 (7.0 seconds)
|
---|
158 |
|
---|
159 | Device Statistics (GP Log 0x04)
|
---|
160 | Page Offset Size Value Flags Description
|
---|
161 | 0x01 ===== = = === == General Statistics (rev 1) ==
|
---|
162 | 0x01 0x008 4 36 --- Lifetime Power-On Resets
|
---|
163 | 0x01 0x010 4 24 --- Power-on Hours
|
---|
164 | 0x01 0x018 6 4005022518 --- Logical Sectors Written
|
---|
165 | 0x01 0x020 6 4428214 --- Number of Write Commands
|
---|
166 | 0x01 0x028 6 10917211 --- Logical Sectors Read
|
---|
167 | 0x01 0x030 6 79066 --- Number of Read Commands
|
---|
168 | 0x01 0x038 6 86400000 --- Date and Time TimeStamp
|
---|
169 | 0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
---|
170 | 0x03 0x008 4 24 --- Spindle Motor Power-on Hours
|
---|
171 | 0x03 0x010 4 24 --- Head Flying Hours
|
---|
172 | 0x03 0x018 4 37 --- Head Load Events
|
---|
173 | 0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
---|
174 | 0x03 0x028 4 0 --- Read Recovery Attempts
|
---|
175 | 0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
---|
176 | 0x03 0x038 4 0 --- Number of Realloc. Candidate Logical Sectors
|
---|
177 | 0x03 0x040 4 17 --- Number of High Priority Unload Events
|
---|
178 | 0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
---|
179 | 0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
---|
180 | 0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
---|
181 | 0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
---|
182 | 0x05 0x008 1 32 --- Current Temperature
|
---|
183 | 0x05 0x010 1 - --- Average Short Term Temperature
|
---|
184 | 0x05 0x018 1 - --- Average Long Term Temperature
|
---|
185 | 0x05 0x020 1 38 --- Highest Temperature
|
---|
186 | 0x05 0x028 1 26 --- Lowest Temperature
|
---|
187 | 0x05 0x030 1 - --- Highest Average Short Term Temperature
|
---|
188 | 0x05 0x038 1 - --- Lowest Average Short Term Temperature
|
---|
189 | 0x05 0x040 1 - --- Highest Average Long Term Temperature
|
---|
190 | 0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
---|
191 | 0x05 0x050 4 0 --- Time in Over-Temperature
|
---|
192 | 0x05 0x058 1 65 --- Specified Maximum Operating Temperature
|
---|
193 | 0x05 0x060 4 0 --- Time in Under-Temperature
|
---|
194 | 0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
---|
195 | 0x06 ===== = = === == Transport Statistics (rev 1) ==
|
---|
196 | 0x06 0x008 4 188 --- Number of Hardware Resets
|
---|
197 | 0x06 0x010 4 70 --- Number of ASR Events
|
---|
198 | 0x06 0x018 4 0 --- Number of Interface CRC Errors
|
---|
199 | |||_ C monitored condition met
|
---|
200 | ||__ D supports DSN
|
---|
201 | |___ N normalized value
|
---|
202 |
|
---|
203 | Pending Defects log (GP Log 0x0c) not supported
|
---|
204 |
|
---|
205 | SATA Phy Event Counters (GP Log 0x11)
|
---|
206 | ID Size Value Description
|
---|
207 | 0x0001 2 0 Command failed due to ICRC error
|
---|
208 | 0x0002 2 0 R_ERR response for data FIS
|
---|
209 | 0x0003 2 0 R_ERR response for device-to-host data FIS
|
---|
210 | 0x0004 2 0 R_ERR response for host-to-device data FIS
|
---|
211 | 0x0005 2 0 R_ERR response for non-data FIS
|
---|
212 | 0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
---|
213 | 0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
---|
214 | 0x0008 2 0 Device-to-host non-data FIS retries
|
---|
215 | 0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
---|
216 | 0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
---|
217 | 0x000b 2 0 CRC errors within host-to-device FIS
|
---|
218 | 0x000d 2 0 Non-CRC errors within host-to-device FIS
|
---|
219 | 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
---|
220 | 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
---|
221 | 0x8000 4 34758 Vendor specific
|
---|
222 |
|
---|