Ticket #1689: smartctl-GOODRAM-CX400.txt

File smartctl-GOODRAM-CX400.txt, 11.8 KB (added by Wojciech Niziński, 8 months ago)
Line 
1smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.74-1-pve] (local build)
2Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model:     SSDPR-CX400-128-G2
6Serial Number:    GY2015459
7LU WWN Device Id: 5 000000 0000029de
8Firmware Version: SN07373
9User Capacity:    128 035 676 160 bytes [128 GB]
10Sector Size:      512 bytes logical/physical
11Rotation Rate:    Solid State Device
12Form Factor:      2.5 inches
13TRIM Command:     Available, deterministic, zeroed
14Device is:        Not in smartctl database [for details use: -P showall]
15ATA Version is:   ACS-4 (minor revision not indicated)
16SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
17Local Time is:    Tue Jan 31 12:22:22 2023 CET
18SMART support is: Available - device has SMART capability.
19SMART support is: Enabled
20AAM feature is:   Unavailable
21APM feature is:   Unavailable
22Rd look-ahead is: Enabled
23Write cache is:   Enabled
24DSN feature is:   Unavailable
25ATA Security is:  Disabled, NOT FROZEN [SEC1]
26Wt Cache Reorder: Enabled
27
28=== START OF READ SMART DATA SECTION ===
29SMART overall-health self-assessment test result: PASSED
30
31General SMART Values:
32Offline data collection status:  (0x02) Offline data collection activity
33                                        was completed without error.
34                                        Auto Offline Data Collection: Disabled.
35Self-test execution status:      (   0) The previous self-test routine completed
36                                        without error or no self-test has ever
37                                        been run.
38Total time to complete Offline
39data collection:                (   33) seconds.
40Offline data collection
41capabilities:                    (0x7b) SMART execute Offline immediate.
42                                        Auto Offline data collection on/off support.
43                                        Suspend Offline collection upon new
44                                        command.
45                                        Offline surface scan supported.
46                                        Self-test supported.
47                                        Conveyance Self-test supported.
48                                        Selective Self-test supported.
49SMART capabilities:            (0x0003) Saves SMART data before entering
50                                        power-saving mode.
51                                        Supports SMART auto save timer.
52Error logging capability:        (0x01) Error logging supported.
53                                        General Purpose Logging supported.
54Short self-test routine
55recommended polling time:        (   2) minutes.
56Extended self-test routine
57recommended polling time:        (   2) minutes.
58Conveyance self-test routine
59recommended polling time:        (   2) minutes.
60SCT capabilities:              (0x0031) SCT Status supported.
61                                        SCT Feature Control supported.
62                                        SCT Data Table supported.
63
64SMART Attributes Data Structure revision number: 20
65Vendor Specific SMART Attributes with Thresholds:
66ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
67  5 Reallocated_Sector_Ct   PO--C-   100   100   050    -    0
68  9 Power_On_Hours          -O--C-   100   100   000    -    10156
69 12 Power_Cycle_Count       -O--C-   100   100   000    -    14
70167 Unknown_Attribute       -O---K   100   100   000    -    0
71168 Unknown_Attribute       -O--C-   100   100   000    -    0
72169 Unknown_Attribute       PO--C-   100   100   010    -    0
73171 Unknown_Attribute       -O--CK   000   000   000    -    0
74172 Unknown_Attribute       -O--CK   000   000   000    -    0
75173 Unknown_Attribute       -O--C-   200   200   000    -    14783588602381
76174 Unknown_Attribute       -O---K   100   100   000    -    0
77175 Program_Fail_Count_Chip -O---K   100   100   010    -    0
78180 Unused_Rsvd_Blk_Cnt_Tot PO--CK   100   100   000    -    36
79187 Reported_Uncorrect      -O--CK   100   000   000    -    0
80192 Power-Off_Retract_Count -O--C-   100   100   000    -    14
81194 Temperature_Celsius     -O---K   040   040   000    -    40 (Min/Max 10/50)
82206 Unknown_SSD_Attribute   -O--CK   200   200   000    -    3442
83207 Unknown_SSD_Attribute   -O--CK   200   200   000    -    4748
84208 Unknown_SSD_Attribute   -O--CK   200   200   000    -    4621
85209 Unknown_SSD_Attribute   -O--CK   200   200   000    -    1
86210 Unknown_Attribute       -O--CK   200   200   000    -    15335
87211 Unknown_Attribute       -O--CK   200   200   000    -    11992
88231 Unknown_SSD_Attribute   PO---K   010   010   005    -    92
89241 Total_LBAs_Written      -O--CK   100   100   000    -    120561
90242 Total_LBAs_Read         -O--CK   100   100   000    -    1365
91243 Unknown_Attribute       -O--CK   050   050   000    -    8587640796
92245 Unknown_Attribute       -O--CK   100   100   000    -    26
93                            ||||||_ K auto-keep
94                            |||||__ C event count
95                            ||||___ R error rate
96                            |||____ S speed/performance
97                            ||_____ O updated online
98                            |______ P prefailure warning
99
100General Purpose Log Directory Version 1
101SMART           Log Directory Version 1 [multi-sector log support]
102Address    Access  R/W   Size  Description
1030x00       GPL,SL  R/O      1  Log Directory
1040x01           SL  R/O      1  Summary SMART error log
1050x02           SL  R/O     51  Comprehensive SMART error log
1060x03       GPL     R/O     64  Ext. Comprehensive SMART error log
1070x04       GPL,SL  R/O      8  Device Statistics log
1080x06           SL  R/O      1  SMART self-test log
1090x07       GPL     R/O      1  Extended self-test log
1100x09           SL  R/W      1  Selective self-test log
1110x10       GPL     R/O      1  NCQ Command Error log
1120x11       GPL     R/O      1  SATA Phy Event Counters log
1130x30       GPL,SL  R/O      9  IDENTIFY DEVICE data log
1140x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
1150xe0       GPL,SL  R/W      1  SCT Command/Status
1160xe1       GPL,SL  R/W      1  SCT Data Transfer
117
118SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
119Device Error Count: 1
120        CR     = Command Register
121        FEATR  = Features Register
122        COUNT  = Count (was: Sector Count) Register
123        LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
124        LH     = LBA High (was: Cylinder High) Register    ]   LBA
125        LM     = LBA Mid (was: Cylinder Low) Register      ] Register
126        LL     = LBA Low (was: Sector Number) Register     ]
127        DV     = Device (was: Device/Head) Register
128        DC     = Device Control Register
129        ER     = Error register
130        ST     = Status register
131Powered_Up_Time is measured from power on, and printed as
132DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
133SS=sec, and sss=millisec. It "wraps" after 49.710 days.
134
135Error 1 [0] occurred at disk power-on lifetime: 9028 hours (376 days + 4 hours)
136  When the command that caused the error occurred, the device was in an unknown state.
137
138  After command completion occurred, registers were:
139  ER -- ST COUNT  LBA_48  LH LM LL DV DC
140  -- -- -- == -- == == == -- -- -- -- --
141  84 -- 41 00 08 00 00 01 47 66 40 40 00
142
143  Commands leading to the command that caused the error were:
144  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
145  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
146  ea 00 00 00 00 00 00 00 00 00 00 00 80     06:46:01.808  FLUSH CACHE EXT
147  ea 00 00 00 00 00 00 00 00 00 00 00 80     06:46:01.808  FLUSH CACHE EXT
148  ea 00 00 00 00 00 00 00 00 00 00 00 80     06:46:01.808  FLUSH CACHE EXT
149  ea 00 00 00 00 00 00 00 00 00 00 00 80     06:46:01.708  FLUSH CACHE EXT
150  ea 00 00 00 00 00 00 00 00 00 00 00 80     06:46:01.708  FLUSH CACHE EXT
151
152SMART Extended Self-test Log Version: 1 (1 sectors)
153Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
154# 1  Short offline       Completed without error       00%     10156         -
155# 2  Short offline       Completed without error       00%     10125         -
156# 3  Short offline       Completed without error       00%     10103         -
157# 4  Short offline       Completed without error       00%     10080         -
158# 5  Extended offline    Completed without error       00%     10079         -
159# 6  Short offline       Completed without error       00%     10058         -
160# 7  Short offline       Completed without error       00%     10036         -
161# 8  Short offline       Completed without error       00%     10013         -
162# 9  Short offline       Completed without error       00%      9991         -
163#10  Short offline       Completed without error       00%      9969         -
164#11  Short offline       Completed without error       00%      9947         -
165#12  Short offline       Completed without error       00%      9925         -
166#13  Extended offline    Completed without error       00%      9924         -
167#14  Short offline       Completed without error       00%      9903         -
168#15  Short offline       Completed without error       00%      9881         -
169#16  Short offline       Completed without error       00%      9859         -
170#17  Short offline       Completed without error       00%      9836         -
171#18  Short offline       Completed without error       00%      9814         -
172#19  Short offline       Completed without error       00%      9792         -
173
174SMART Selective self-test log data structure revision number 1
175 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
176    1        0        0  Not_testing
177    2        0        0  Not_testing
178    3        0        0  Not_testing
179    4        0        0  Not_testing
180    5        0        0  Not_testing
181Selective self-test flags (0x0):
182  After scanning selected spans, do NOT read-scan remainder of disk.
183If Selective self-test is pending on power-up, resume after 0 minute delay.
184
185SCT Status Version:                  3
186SCT Version (vendor specific):       1 (0x0001)
187Device State:                        Active (0)
188Current Temperature:                    40 Celsius
189Power Cycle Min/Max Temperature:      ?/40 Celsius
190Lifetime    Min/Max Temperature:      ?/ ? Celsius
191Under/Over Temperature Limit Count:   0/0
192
193SCT Temperature History Version:     2
194Temperature Sampling Period:         1 minute
195Temperature Logging Interval:        1 minute
196Min/Max recommended Temperature:     -127/127 Celsius
197Min/Max Temperature Limit:           -127/127 Celsius
198Temperature History Size (Index):    478 (85)
199
200Index    Estimated Time   Temperature Celsius
201  86    2023-01-31 04:25    40  *********************
202 ...    ..(476 skipped).    ..  *********************
203  85    2023-01-31 12:22    40  *********************
204
205SCT Error Recovery Control command not supported
206
207Device Statistics (GP Log 0x04)
208Page  Offset Size        Value Flags Description
2090x01  =====  =               =  ===  == General Statistics (rev 1) ==
2100x01  0x008  4              14  ---  Lifetime Power-On Resets
2110x01  0x010  4           10156  ---  Power-on Hours
2120x01  0x018  6    252836733976  ---  Logical Sectors Written
2130x01  0x020  6      4407726815  ---  Number of Write Commands
2140x01  0x028  6      2863129624  ---  Logical Sectors Read
2150x01  0x030  6       114107444  ---  Number of Read Commands
2160x01  0x038  6   8239873220456  ---  Date and Time TimeStamp
2170x07  =====  =               =  ===  == Solid State Device Statistics (rev 1) ==
2180x07  0x008  1             189  N--  Percentage Used Endurance Indicator
219                                |||_ C monitored condition met
220                                ||__ D supports DSN
221                                |___ N normalized value
222
223Pending Defects log (GP Log 0x0c) not supported
224
225SATA Phy Event Counters (GP Log 0x11)
226ID      Size     Value  Description
2270x0001  2            1  Command failed due to ICRC error
2280x0003  2            0  R_ERR response for device-to-host data FIS
2290x0004  2            0  R_ERR response for host-to-device data FIS
2300x0006  2            0  R_ERR response for device-to-host non-data FIS
2310x0007  2            0  R_ERR response for host-to-device non-data FIS
2320x0008  2            0  Device-to-host non-data FIS retries
2330x0009  4            0  Transition from drive PhyRdy to drive PhyNRdy
2340x000a  4           43  Device-to-host register FISes sent due to a COMRESET
2350x000f  2            0  R_ERR response for host-to-device data FIS, CRC
2360x0010  2            0  R_ERR response for host-to-device data FIS, non-CRC
2370x0012  2            0  R_ERR response for host-to-device non-data FIS, CRC
2380x0013  2            0  R_ERR response for host-to-device non-data FIS, non-CRC
239