Ticket #1661: smartctl-SKhynix-SC308SATA256GB.txt

File smartctl-SKhynix-SC308SATA256GB.txt, 6.7 KB (added by Aaron A Brown, 18 months ago)

Device Model: SK hynix SC308 SATA 256GB

Line 
1smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-29-generic] (local build)
2Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
3
4=== START OF INFORMATION SECTION ===
5Device Model: SK hynix SC308 SATA 256GB
6Serial Number: FJ68N485411008G5I
7Firmware Version: 30000P10
8User Capacity: 256,060,514,304 bytes [256 GB]
9Sector Sizes: 512 bytes logical, 4096 bytes physical
10Rotation Rate: Solid State Device
11Form Factor: 2.5 inches
12Device is: Not in smartctl database [for details use: -P showall]
13ATA Version is: ACS-2 (minor revision not indicated)
14SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
15Local Time is: Thu Oct 20 18:07:09 2022 UTC
16SMART support is: Available - device has SMART capability.
17SMART support is: Enabled
18AAM feature is: Unavailable
19APM feature is: Disabled
20Rd look-ahead is: Enabled
21Write cache is: Enabled
22ATA Security is: Disabled, NOT FROZEN [SEC1]
23Wt Cache Reorder: Unavailable
24
25=== START OF READ SMART DATA SECTION ===
26SMART overall-health self-assessment test result: FAILED!
27Drive failure expected in less than 24 hours. SAVE ALL DATA.
28See vendor-specific Attribute list for failed Attributes.
29
30General SMART Values:
31Offline data collection status: (0x06) Offline data collection activity
32 was aborted by the device with a fatal error.
33 Auto Offline Data Collection: Disabled.
34Self-test execution status: ( 137) The previous self-test completed having
35 a test element that failed and the
36 device is suspected of having handling
37 damage.
38Total time to complete Offline
39data collection: ( 0) seconds.
40Offline data collection
41capabilities: (0x19) SMART execute Offline immediate.
42 No Auto Offline data collection support.
43 Suspend Offline collection upon new
44 command.
45 Offline surface scan supported.
46 Self-test supported.
47 No Conveyance Self-test supported.
48 No Selective Self-test supported.
49SMART capabilities: (0x0002) Does not save SMART data before
50 entering power-saving mode.
51 Supports SMART auto save timer.
52Error logging capability: (0x01) Error logging supported.
53 General Purpose Logging supported.
54Short self-test routine
55recommended polling time: ( 2) minutes.
56Extended self-test routine
57recommended polling time: ( 20) minutes.
58
59SMART Attributes Data Structure revision number: 0
60Vendor Specific SMART Attributes with Thresholds:
61ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
62 1 Raw_Read_Error_Rate POSR-- 166 166 006 - 0
63 5 Reallocated_Sector_Ct -O--CK 253 100 036 - 0
64 9 Power_On_Hours -O--CK 068 068 000 - 28816
65 12 Power_Cycle_Count -O--CK 100 100 020 - 238
66100 Unknown_Attribute -O--CK 099 099 000 - 69174854
67171 Unknown_Attribute -O--CK 253 253 000 - 0
68172 Unknown_Attribute -O--CK 253 253 000 - 0
69174 Unknown_Attribute ----CK 100 100 000 - 27
70175 Program_Fail_Count_Chip -O--CK 253 253 000 - 0
71176 Erase_Fail_Count_Chip -O--CK 253 253 000 - 0
72177 Wear_Leveling_Count -O--CK 002 002 000 - 1048
73178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 000 - 19
74179 Used_Rsvd_Blk_Cnt_Tot -O--CK 100 100 000 - 167
75180 Unused_Rsvd_Blk_Cnt_Tot -O--CK 100 100 000 - 5305
76181 Program_Fail_Cnt_Total -O--CK 253 253 000 - 0
77182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0
78183 Runtime_Bad_Block -O--CK 253 253 000 - 0
79187 Reported_Uncorrect -O--CK 253 253 000 - 0
80188 Command_Timeout -O--CK 253 253 000 - 0
81191 Unknown_SSD_Attribute -O--CK 253 253 000 - 0
82194 Temperature_Celsius -O---- 026 000 000 - 26 (Min/Max 16/41)
83195 Hardware_ECC_Recovered -O--CK 253 253 000 - 0
84199 UDMA_CRC_Error_Count -O--CK 253 253 000 - 0
85201 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
86204 Soft_ECC_Correction -OSR-- 100 001 000 - 0
87231 Temperature_Celsius PO--CK 002 002 010 NOW 99
88234 Unknown_Attribute -O--CK 100 100 000 - 569502220608
89241 Total_LBAs_Written -O--CK 100 100 000 - 18882661392
90242 Total_LBAs_Read -O--CK 100 100 000 - 13471194205
91250 Read_Error_Retry_Rate -O--CK 100 100 000 - 23681165
92 ||||||_ K auto-keep
93 |||||__ C event count
94 ||||___ R error rate
95 |||____ S speed/performance
96 ||_____ O updated online
97 |______ P prefailure warning
98
99General Purpose Log Directory Version 1
100SMART Log Directory Version 1 [multi-sector log support]
101Address Access R/W Size Description
1020x00 GPL,SL R/O 1 Log Directory
1030x01 SL R/O 1 Summary SMART error log
1040x02 SL R/O 4 Comprehensive SMART error log
1050x03 GPL R/O 5 Ext. Comprehensive SMART error log
1060x04 GPL,SL R/O 8 Device Statistics log
1070x06 SL R/O 1 SMART self-test log
1080x07 GPL R/O 2 Extended self-test log
1090x10 GPL R/O 1 SATA NCQ Queued Error log
1100x11 GPL R/O 1 SATA Phy Event Counters log
1110x30 GPL R/O 8 IDENTIFY DEVICE data log
1120x80-0x9f GPL,SL R/W 16 Host vendor specific log
113
114SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
115No Errors Logged
116
117SMART Extended Self-test Log Version: 1 (2 sectors)
118Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
119# 1 Short offline Completed: handling damage?? 90% 28816 54700424
120# 2 Short offline Completed without error 00% 0 -
121
122Selective Self-tests/Logging not supported
123
124SCT Commands not supported
125
126Device Statistics (GP Log 0x04)
127Page Offset Size Value Flags Description
1280x01 ===== = = === == General Statistics (empty) ==
1290x04 ===== = = === == General Errors Statistics (empty) ==
1300x05 ===== = = === == Temperature Statistics (empty) ==
1310x06 ===== = = === == Transport Statistics (empty) ==
1320x07 ===== = = === == Solid State Device Statistics (empty) ==
133 |||_ C monitored condition met
134 ||__ D supports DSN
135 |___ N normalized value
136
137SATA Phy Event Counters (GP Log 0x11)
138ID Size Value Description
1390x0001 2 0 Command failed due to ICRC error
1400x000a 2 2 Device-to-host register FISes sent due to a COMRESET
141