1 | smartctl 7.3 2022-02-28 r5338 [i686-w64-mingw32-win7-sp1(64)] (sf-7.3-1)
|
---|
2 | Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
---|
3 |
|
---|
4 | === START OF INFORMATION SECTION ===
|
---|
5 | Device Model: #DI LCB0D #DFULCB0D0033
|
---|
6 | Serial Number: 75UECBGIT
|
---|
7 | LU WWN Device Id: 5 000039 66398a103
|
---|
8 | Firmware Version: AM001K
|
---|
9 | User Capacity: 320,072,933,376 bytes [320 GB]
|
---|
10 | Sector Sizes: 512 bytes logical, 4096 bytes physical
|
---|
11 | Rotation Rate: 5400 rpm
|
---|
12 | Form Factor: 2.5 inches
|
---|
13 | Device is: Not in smartctl database 7.3/5319
|
---|
14 | ATA Version is: ATA8-ACS (minor revision not indicated)
|
---|
15 | SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
---|
16 | Local Time is: Thu Jul 21 12:14:43 2022 CDT
|
---|
17 | SMART support is: Available - device has SMART capability.
|
---|
18 | SMART support is: Enabled
|
---|
19 |
|
---|
20 | === START OF READ SMART DATA SECTION ===
|
---|
21 | SMART overall-health self-assessment test result: PASSED
|
---|
22 |
|
---|
23 | General SMART Values:
|
---|
24 | Offline data collection status: (0x00) Offline data collection activity
|
---|
25 | was never started.
|
---|
26 | Auto Offline Data Collection: Disabled.
|
---|
27 | Self-test execution status: ( 0) The previous self-test routine completed
|
---|
28 | without error or no self-test has ever
|
---|
29 | been run.
|
---|
30 | Total time to complete Offline
|
---|
31 | data collection: ( 120) seconds.
|
---|
32 | Offline data collection
|
---|
33 | capabilities: (0x5b) SMART execute Offline immediate.
|
---|
34 | Auto Offline data collection on/off support.
|
---|
35 | Suspend Offline collection upon new
|
---|
36 | command.
|
---|
37 | Offline surface scan supported.
|
---|
38 | Self-test supported.
|
---|
39 | No Conveyance Self-test supported.
|
---|
40 | Selective Self-test supported.
|
---|
41 | SMART capabilities: (0x0003) Saves SMART data before entering
|
---|
42 | power-saving mode.
|
---|
43 | Supports SMART auto save timer.
|
---|
44 | Error logging capability: (0x01) Error logging supported.
|
---|
45 | General Purpose Logging supported.
|
---|
46 | Short self-test routine
|
---|
47 | recommended polling time: ( 2) minutes.
|
---|
48 | Extended self-test routine
|
---|
49 | recommended polling time: ( 69) minutes.
|
---|
50 | SCT capabilities: (0x003d) SCT Status supported.
|
---|
51 | SCT Error Recovery Control supported.
|
---|
52 | SCT Feature Control supported.
|
---|
53 | SCT Data Table supported.
|
---|
54 |
|
---|
55 | SMART Attributes Data Structure revision number: 16
|
---|
56 | Vendor Specific SMART Attributes with Thresholds:
|
---|
57 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
---|
58 | 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
|
---|
59 | 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
|
---|
60 | 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1356
|
---|
61 | 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 1292
|
---|
62 | 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 0
|
---|
63 | 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
|
---|
64 | 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
|
---|
65 | 9 Power_On_Hours 0x0032 071 071 000 Old_age Always - 11942
|
---|
66 | 10 Spin_Retry_Count 0x0033 125 100 030 Pre-fail Always - 0
|
---|
67 | 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1283
|
---|
68 | 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 17
|
---|
69 | 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 66
|
---|
70 | 193 Load_Cycle_Count 0x0032 090 090 000 Old_age Always - 105549
|
---|
71 | 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Min/Max 12/49)
|
---|
72 | 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
|
---|
73 | 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
|
---|
74 | 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
|
---|
75 | 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
|
---|
76 | 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 0
|
---|
77 | 222 Loaded_Hours 0x0032 071 071 000 Old_age Always - 11853
|
---|
78 | 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
---|
79 | 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
|
---|
80 | 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 247
|
---|
81 | 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
|
---|
82 |
|
---|
83 | SMART Error Log Version: 1
|
---|
84 | ATA Error Count: 283 (device log contains only the most recent five errors)
|
---|
85 | CR = Command Register [HEX]
|
---|
86 | FR = Features Register [HEX]
|
---|
87 | SC = Sector Count Register [HEX]
|
---|
88 | SN = Sector Number Register [HEX]
|
---|
89 | CL = Cylinder Low Register [HEX]
|
---|
90 | CH = Cylinder High Register [HEX]
|
---|
91 | DH = Device/Head Register [HEX]
|
---|
92 | DC = Device Command Register [HEX]
|
---|
93 | ER = Error register [HEX]
|
---|
94 | ST = Status register [HEX]
|
---|
95 | Powered_Up_Time is measured from power on, and printed as
|
---|
96 | DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
---|
97 | SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
---|
98 |
|
---|
99 | Error 283 occurred at disk power-on lifetime: 9243 hours (385 days + 3 hours)
|
---|
100 | When the command that caused the error occurred, the device was active or idle.
|
---|
101 |
|
---|
102 | After command completion occurred, registers were:
|
---|
103 | ER ST SC SN CL CH DH
|
---|
104 | -- -- -- -- -- -- --
|
---|
105 | 40 41 00 70 8e f3 40 Error: WP at LBA = 0x00f38e70 = 15961712
|
---|
106 |
|
---|
107 | Commands leading to the command that caused the error were:
|
---|
108 | CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
---|
109 | -- -- -- -- -- -- -- -- ---------------- --------------------
|
---|
110 | 61 48 70 50 c5 03 40 00 07:34:10.367 WRITE FPDMA QUEUED
|
---|
111 | 61 00 68 b8 a0 f5 40 00 07:34:10.367 WRITE FPDMA QUEUED
|
---|
112 | 61 00 60 b8 9f f5 40 00 07:34:10.367 WRITE FPDMA QUEUED
|
---|
113 | 61 00 58 b8 9e f5 40 00 07:34:10.367 WRITE FPDMA QUEUED
|
---|
114 | 61 00 50 b8 9d f5 40 00 07:34:10.367 WRITE FPDMA QUEUED
|
---|
115 |
|
---|
116 | Error 282 occurred at disk power-on lifetime: 9243 hours (385 days + 3 hours)
|
---|
117 | When the command that caused the error occurred, the device was active or idle.
|
---|
118 |
|
---|
119 | After command completion occurred, registers were:
|
---|
120 | ER ST SC SN CL CH DH
|
---|
121 | -- -- -- -- -- -- --
|
---|
122 | 40 41 00 70 8e f3 40 Error: WP at LBA = 0x00f38e70 = 15961712
|
---|
123 |
|
---|
124 | Commands leading to the command that caused the error were:
|
---|
125 | CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
---|
126 | -- -- -- -- -- -- -- -- ---------------- --------------------
|
---|
127 | 61 08 20 a0 30 03 40 00 07:33:10.091 WRITE FPDMA QUEUED
|
---|
128 | 61 08 30 80 92 05 40 00 07:33:09.640 WRITE FPDMA QUEUED
|
---|
129 | 61 08 20 f0 8a 10 40 00 07:33:09.639 WRITE FPDMA QUEUED
|
---|
130 | 61 08 28 90 0f 08 40 00 07:33:09.639 WRITE FPDMA QUEUED
|
---|
131 | 61 08 20 b8 51 05 40 00 07:33:09.639 WRITE FPDMA QUEUED
|
---|
132 |
|
---|
133 | Error 281 occurred at disk power-on lifetime: 9243 hours (385 days + 3 hours)
|
---|
134 | When the command that caused the error occurred, the device was active or idle.
|
---|
135 |
|
---|
136 | After command completion occurred, registers were:
|
---|
137 | ER ST SC SN CL CH DH
|
---|
138 | -- -- -- -- -- -- --
|
---|
139 | 40 41 40 70 8e f3 40 Error: UNC at LBA = 0x00f38e70 = 15961712
|
---|
140 |
|
---|
141 | Commands leading to the command that caused the error were:
|
---|
142 | CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
---|
143 | -- -- -- -- -- -- -- -- ---------------- --------------------
|
---|
144 | 60 08 28 30 6c ee 40 00 07:33:00.270 READ FPDMA QUEUED
|
---|
145 | 60 20 08 69 75 16 40 00 07:33:00.270 READ FPDMA QUEUED
|
---|
146 | 61 00 00 40 44 05 40 00 07:32:59.952 WRITE FPDMA QUEUED
|
---|
147 | 61 00 f8 40 45 05 40 00 07:32:59.952 WRITE FPDMA QUEUED
|
---|
148 | 61 00 f0 40 46 05 40 00 07:32:59.952 WRITE FPDMA QUEUED
|
---|
149 |
|
---|
150 | Error 280 occurred at disk power-on lifetime: 9243 hours (385 days + 3 hours)
|
---|
151 | When the command that caused the error occurred, the device was active or idle.
|
---|
152 |
|
---|
153 | After command completion occurred, registers were:
|
---|
154 | ER ST SC SN CL CH DH
|
---|
155 | -- -- -- -- -- -- --
|
---|
156 | 40 41 00 70 8e f3 40 Error: WP at LBA = 0x00f38e70 = 15961712
|
---|
157 |
|
---|
158 | Commands leading to the command that caused the error were:
|
---|
159 | CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
---|
160 | -- -- -- -- -- -- -- -- ---------------- --------------------
|
---|
161 | 61 08 10 58 69 05 40 00 07:30:33.356 WRITE FPDMA QUEUED
|
---|
162 | 61 08 10 88 30 03 40 00 07:30:33.138 WRITE FPDMA QUEUED
|
---|
163 | 61 08 10 a0 30 03 40 00 07:30:33.138 WRITE FPDMA QUEUED
|
---|
164 | 61 20 10 60 c3 03 40 00 07:30:33.137 WRITE FPDMA QUEUED
|
---|
165 | 60 20 08 69 75 16 40 00 07:30:32.933 READ FPDMA QUEUED
|
---|
166 |
|
---|
167 | Error 279 occurred at disk power-on lifetime: 9243 hours (385 days + 3 hours)
|
---|
168 | When the command that caused the error occurred, the device was active or idle.
|
---|
169 |
|
---|
170 | After command completion occurred, registers were:
|
---|
171 | ER ST SC SN CL CH DH
|
---|
172 | -- -- -- -- -- -- --
|
---|
173 | 40 41 00 70 8e f3 40 Error: WP at LBA = 0x00f38e70 = 15961712
|
---|
174 |
|
---|
175 | Commands leading to the command that caused the error were:
|
---|
176 | CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
---|
177 | -- -- -- -- -- -- -- -- ---------------- --------------------
|
---|
178 | 61 08 08 98 30 03 40 00 07:30:15.573 WRITE FPDMA QUEUED
|
---|
179 | 61 20 08 d8 c2 03 40 00 07:30:15.573 WRITE FPDMA QUEUED
|
---|
180 | 61 00 40 00 ec fc 40 00 07:30:15.435 WRITE FPDMA QUEUED
|
---|
181 | 61 00 38 00 eb fc 40 00 07:30:15.435 WRITE FPDMA QUEUED
|
---|
182 | 61 00 30 00 ea fc 40 00 07:30:15.435 WRITE FPDMA QUEUED
|
---|
183 |
|
---|
184 | SMART Self-test log structure revision number 1
|
---|
185 | No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
---|
186 |
|
---|
187 | SMART Selective self-test log data structure revision number 1
|
---|
188 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
---|
189 | 1 0 0 Not_testing
|
---|
190 | 2 0 0 Not_testing
|
---|
191 | 3 0 0 Not_testing
|
---|
192 | 4 0 0 Not_testing
|
---|
193 | 5 0 0 Not_testing
|
---|
194 | Selective self-test flags (0x0):
|
---|
195 | After scanning selected spans, do NOT read-scan remainder of disk.
|
---|
196 | If Selective self-test is pending on power-up, resume after 0 minute delay.
|
---|
197 |
|
---|